Reference Guide
OS10(conf-vfabric-100)# zoneset activate set
OS10(conf-vfabric-100)# zone default-zone permit
View FC zone conguration
OS10(config-fc-zone-hba1)# show configuration
!
fc zone hba1
 member wwn 21:00:00:24:ff:7b:f5:c8
 member wwn 10:00:00:90:fa:b8:22:19
OS10# show fc zone
 Zone Name Zone Member
=================================================
hba1 21:00:00:24:ff:7b:f5:c8
 10:00:00:90:fa:b8:22:19
hba2 20:01:00:0e:1e:e8:e4:99
 50:00:d3:10:00:ec:f9:1b
 50:00:d3:10:00:ec:f9:05
 50:00:d3:10:00:ec:f9:1f
 20:35:78:2b:cb:6f:65:57
View FC zoneset conguration
OS10(conf-fc-zoneset-set)# show configuration
!
fc zoneset set
 member hba1
 member hba2
OS10# show fc zoneset active
vFabric id: 100
Active Zoneset: set
ZoneName ZoneMember
================================================
hba2 *20:01:00:0e:1e:e8:e4:99 
 20:35:78:2b:cb:6f:65:57 
 50:00:d3:10:00:ec:f9:05 
 50:00:d3:10:00:ec:f9:1b 
 50:00:d3:10:00:ec:f9:1f 
hba1 *10:00:00:90:fa:b8:22:19
 *21:00:00:24:ff:7b:f5:c8 
OS10# show fc zoneset set
ZoneSetName ZoneName ZoneMember
==========================================================
set hba1 21:00:00:24:ff:7b:f5:c8
 10:00:00:90:fa:b8:22:19
 21:00:00:24:ff:7f:ce:ee
 21:00:00:24:ff:7f:ce:ef
 hba2 20:01:00:0e:1e:e8:e4:99
 50:00:d3:10:00:ec:f9:1b
 50:00:d3:10:00:ec:f9:05
 50:00:d3:10:00:ec:f9:1f
 20:35:78:2b:cb:6f:65:57
F_Port on Ethernet
OS10 supports conguring F_Port mode on an Ethernet port that is connected to converged network adapters (CNA).
After enabling F_Port mode, congure a vfabric and apply the vfabric to Ethernet ports connected to CNA.
130