Reference Guide
Example
curl -X POST -k -u admin:admin -H "accept: application/json" 
-H "Content-Type: application/json" “https://10.11.86.113/restconf/data/
interfaces” 
-d '{"interface": [{"type":"iana-if-type:ieee8023adLag","name":"port-
channel10"}]}' 
Assign VLT port-channel ID to VLT port channel
RESTCONF 
endpoint
/restconf/data/interfaces/interface/port-channel10
JSON content
{
 "interface": [{
 "type": "iana-if-type:ieee8023adLag",
 "name": "port-channel10",
 "enabled": "true",
 "dell-vlt:vlt": {
 "vlt-id": "1"
 }
 }]
}
Parameters
• port-channelid-number — Enter port-channelid-number, where id-number is 1 to 128.
• type string — Enter iana-if-type:ieee8023adLag for a port-channel interface.
• name string — Enter port-channelid-number.
• enabled bool — Enter true (no shutdown) to enable the port channel; enter false (shutdown) to 
disable the port channel.
• vlt-id int — Enter the VLT port-channel ID, from 1 to 1024.
Example
curl -X PATCH -k -u admin:admin -H "accept: application/json" 
-H "Content-Type: application/json" 
"https://10.11.86.113/restconf/data/interfaces/interface/port-channel10" 
-d '{"interface":[{"type":"iana-if-type:ieee8023adLag", "name":"port-
channel10", 
"enabled":"true", "dell-vlt:vlt":{"vlt-id":"1"}}]}'
Delete VLT domain
RESTCONF 
endpoint
/restconf/data/node-topology/1
JSON content None
Parameters
• topology-id int — Specify the same VLT domain ID on each peer, from 1 to 255.
Example
curl -X DELETE -k -u admin:admin -H "accept: application/json" 
-H "Content-Type: application/json" 
"https://10.11.86.113/restconf/data/node-topology/1"
804 RESTCONF API