Manual
Back to Contents Page
RemoteManagementUnit:Dell™PowerVault™132TTapeLibraryUser's
Guide
The Remote Management Unit (RMU) resides in each system and is pre-installed at the factory. The RMU allows remote access via a Web browser to the
library. Microsoft®Internet Explorer version 5.0 and above, as well as Netscape Navigator versions 4.01 for UNIX®only, and 4.7X for all environments are
supported by the RMU. All available functions, as described below, are accomplished without the need of a dedicated server (or separate software).
The RMU performs the following functions:
l Provides remote operation of all library Operator Panel functions via a Web browser.
l Allows you to check the status of the system, firmware levels, and other useful information.
l Updates RMU and Library Controller firmware for all drive types.
l Updates drive firmware for libraries with LTO drives.
l Supports Simple Network Management Protocol (SNMP) and acts as an SNMP-server, generating SNMP traps and responding to SNMP requests.
l Supports Library Management Information Base (MIB) version 2.0.
l Detects a power loss and generates an SNMP trap for notification.
l Enables the retrieval of library, drive, and RMU diagnostic files.
l Allows RMU configuration changes such as network, users, and date/time changes.
l Stores vital product data (VPD) for libraries with LTO drives.
Figure 1. PowerVault 132T Remote Management Unit
Supported Browsers
The RMU supports the following browsers:
l Microsoft Internet Explorer version 4.0 and above
l Netscape Navigator versions 4.01, 4.5, 4.7X and above
RMU Requirements
The RMU requires a network address that consists of an Internet Protocol (IP) address, subnet mask, and gateway IP Address.
Once these are established, input this information to the RMU via the Operator Panel. For more information, see the discussion that follows.
Setting up the RMU
Once you have established a network address for the RMU, input this information to the RMU via the Operator Panel.
Supported Browsers
Configuring RMU User Accounts
RMU Requirements
Configuring the Time and Date
Setting up the RMU
Updating Firmware
Starting the RMU
Viewing Diagnostic Files
Logging Into the RMU
Rebooting the RMU
Checking Status and General Information
Rebooting the Library
Configuring Network Parameters
Using the Operator Panel (via the RMU)
Configuring SNMP
Getting Help