User Manual
28 About Your System
E1714 Unknown Err The system BIOS has
determined that there has
been an error in the system,
but is unable to determine
its origin.
See "Getting Help" on
page 185.
E171F PCIE Fatal
Err B## D##
F##
PCIE Fatal
Err Slot #
The system BIOS has
reported a PCIe fatal error on
a component that resides in
PCI configuration space at
bus ##, device ##,
function ##.
The system BIOS has
reported a PCIe fatal error on
a component that resides in
slot #.
Remove and reseat the
PCI expansion cards. If
the problem persists, see
"Troubleshooting
Expansion Cards" on
page 168.
If the problem persists,
the system board is faulty.
See "Getting Help" on
page 185.
E1810 HDD ## Fault The SAS subsystem has
determined that hard drive
## has experienced a fault.
See "Troubleshooting a
Hard Drive" on page 164.
E1811 HDD ## Rbld
Abrt
The specified hard drive has
experienced a rebuild abort.
See "Troubleshooting a
Hard Drive" on page 164.
If the problem persists,
see your RAID
documentation.
E1812 HDD ##
Removed
The specified hard drive has
been removed from the
system.
Information only.
E1913 CPU &
Firmware
Mismatch
The BMC firmware does not
support the CPU.
Update to the latest BMC
firmware. See the BMC
User’s Guide for more
information on setup and
use of BMC.
Table 1-6. LCD Status Messages (continued)
Code Text Causes Corrective Actions
book.book Page 28 Monday, September 14, 2009 1:53 PM