Dell DX6104-CSN, DX6104-SN, And DX6104-SCN Object Storage Solutions Getting Started Guide Regulatory Model: E18S Series Regulatory Type: E18S001
Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2012 Dell Inc.
Installation And Configuration WARNING: Before performing the following procedure, review the safety instructions that came with the system. Unpacking A Rack System Unpack your system and identify each item. Assemble the rails and install the system in the rack following the safety instructions and the rack installation instructions provided with your system. Figure 1. Installing the Rails and System in a Rack Optional—Connecting The Keyboard, Mouse, And Monitor Figure 2.
Connecting The Power Cable(s) Figure 3. Connecting the Power Cable(s) Connect the system’s power cable(s) to the system and, if a monitor is used, connect the monitor’s power cable to the monitor. Securing The Power Cable(s) Figure 4. Securing the Power Cable(s) Bend the system power cable(s), as shown in the illustration, and attach to the cable strap.
Turning On The System Figure 5. Turning on the System Press the power button on the system. The power indicator should light. Installing The Optional Bezel Figure 6. Installing the Optional Bezel Install the bezel (optional). Dell Software License Agreement Before using your system, read the Dell Software License Agreement that came with your system. You must consider any media of Dell-installed software as BACKUP copies of the software installed on your system’s hard drive.
Other Information You May Need WARNING: See the safety and regulatory information that shipped with your system. Warranty information may be included within this document or as a separate document. • The Owner’s Manual provides information about system features and describes how to troubleshoot the system and install or replace system components. This document is available online at dell.com/support/manuals.
Power AC Power Supply (per power supply) Wattage 550 W Heat dissipation 2132 BTU/hr maximum (redundant, 550 W power supply) NOTE: Heat dissipation is calculated using the power supply wattage rating. Voltage 100–240 V AC, autoranging, 50/60 Hz NOTE: This system is also designed to be connected to IT power systems with a phase to phase voltage not exceeding 230 V. Battery Coin-cell battery 3 V CR2032 Lithium coin cell Physical Height 42.8 mm (1.68 inch) Width With rack latches 482.4 mm (18.
Environmental Relative humidity Storage 5% to 95% RH with 33 °C (91 °F) maximum dew point. Atmosphere must be non-condensing at all times. Maximum vibration Operating 0.26 Grms at 5 Hz to 350 Hz (all operation orientations). Storage 1.87 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested). Maximum shock Operating One shock pulse in the positive z axis (one pulse on each side of the system) of 31 G for 2.6 m in the operational orientation.
Environmental NOTE: Applies to data center and non-data center environments. Corrosive Dust NOTE: Applies to data center and non-data center environments. • • Air must be free of corrosive dust. Residual dust present in the air must have a deliquescent point less than 60% relative humidity. Gaseous Contamination NOTE: Maximum corrosive contaminant levels measured at ≤50% relative humidity. Copper Coupon Corrosion Rate <300 Å/month per Class G1 as defined by ANSI/ ISA71.04-1985.