Users Guide
Table Of Contents
- Contents
- About This Guide
- About Your Storage Array
- Access Virtual Disk
- Out-of-Band and In-Band Management
- Adding Storage Arrays
- Naming Storage Arrays
- Removing Storage Arrays
- Setting Up Your Storage Array
- Storage Array Support Data
- Setting a Password
- Resetting a Password
- Changing Expansion Enclosure ID Numbers
- Configuring Alert Notifications
- Battery Settings
- Starting or Restarting the Host-Agent Software in Windows
- Starting or Restarting the Host-Agent Software in Linux
- Using iSCSI
- Using the iSCSI Tab
- Changing the iSCSI Target Authentication
- Entering Mutual Authentication Permissions
- Changing the iSCSI Target Identification
- Changing the iSCSI Target Discovery (Optional)
- Configuring the MD3000i iSCSI Host Ports
- Viewing or Ending an iSCSI Session
- Viewing iSCSI Statistics and Setting Baseline Statistics
- Edit, Remove, or Rename Host Topology
- Event Monitor
- About Your Host
- Disk Groups and Virtual Disks
- Premium Feature-Snapshot Virtual Disks
- Premium Feature-Virtual Disk Copy
- Premium Feature-32 Partitions
- Firmware Downloads
- Troubleshooting Problems
- Enclosure Hardware Replacement, Maintenance, and Configuration Considerations
- Index

Troubleshooting 111
b
Make sure that the network can access the host by using the
ping
command in the following syntax:
ping <host-name-or-IP-address-of-the-host>
.
If the network can access the host, continue to step c. If the network
cannot access the host, skip to step d.
c
Remove the host with the unresponsive status from the MD Storage
Manager, and add that host again.
If the host returns to optimal status, you have completed this
procedure.
d
Make sure that the power to the host is turned on and that the host is
operational.
e
If applicable, make sure that the host bus adapters have been installed
in the host.
f
Examine all external cables and switches or hubs to make sure that
you cannot see any damage and that they are tightly connected.
g
If you have recently replaced or added the controller, restart the host-
agent software so that the new controller is found.
If a problem exists, make the appropriate modifications to the host.
4
If you have an out-of-band storage array, use the following procedure. Click
Refresh
after each step to make sure of the results:
a
Make sure that the network can access the controllers by using the
ping
command. Use the following syntax:
ping <controller-IP-address>
.
If the network can access the controllers, continue to step b. If the
network cannot access the controllers, skip to step c.
b
Remove the storage array with the unresponsive status from the MD
Storage Manager, and add that storage array again.
If the storage array returns to optimal status, you have completed this
procedure.
c
Examine the ethernet cables to make sure that you cannot see any
damage and that they are tightly connected.