Dell PowerVault MD3200 and MD3220 Storage Arrays Getting Started With Your System 系统使用入门 Memulai Pengaktifan dengan Sistem Anda はじめに 시스템 시작 안내서
Dell PowerVault MD3200 and MD3220 Storage Arrays Getting Started With Your System Regulatory Model Series E03J and E04J
Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. ____________________ Information in this publication is subject to change without notice. © 2011 Dell Inc. All rights reserved.
Before You Begin NOTE: Throughout the document, Dell PowerVault MD3200 series storage array refers to both Dell PowerVault MD3200 and Dell PowerVault MD3220. Dell PowerVault MD1200 series expansion enclosure refers to both Dell PowerVault MD1200 and Dell PowerVault MD1220. Before setting up your Dell PowerVault MD3200 series storage array, you must consider certain best practices to ensure that your storage array operates at maximum efficiency and offers full redundancy (if required).
• The SMI-S Programmer’s Guide provides information about using the SMI-S provider and SMI-S programming. • Any media that ships with your system that provides documentation and tools for configuring and managing your system, including those pertaining to the operating system, system management software, system updates, and system components that you purchased with your system. NOTE: Always check for updates on support.dell.
Common Configurations Cabling Your Direct-Attached Hosts Server 1 Server 2 Server 3 PowerVault MD3200 series storage array Server 4 Corporate, public, or private network Getting Started With Your System 5
Installation and Configuration WARNING: Before performing the following procedure, review the safety instructions that came with the system. Unpacking the System Unpack your system and identify each item with the packing list that shipped with your system. Installing the Rails and System in a Rack Assemble the rails and install the system in the rack following the safety instructions and the rack installation instructions provided with your system.
Connecting the Power Cable(s) Ensure that the power switch is in the OFF position before connecting the power cables. Connect the system’s power cable(s) to the system. Securing the Power Cable(s) Secure the cable(s) firmly to the bracket using the provided strap. Plug the other end of the power cables into a grounded electrical outlet or a separate power source such as an uninterrupted power supply (UPS) or a power distribution unit (PDU). Each power supply must be connected to a separate power circuit.
Cabling Your Expansion Enclosure PowerVault MD1200 series expansion enclosure 2 (optional) PowerVault MD1200 series expansion enclosure 1 (optional) PowerVault MD3200 series storage array Turning On the Enclosure Turn on the components in the following order: 1 PowerVault MD1200 series expansion enclosures (if used) NOTE: Before turning on the storage array, ensure that the expansion enclosure status LED is blue.
2 PowerVault MD3200 series storage array NOTE: Before turning on the host server(s), ensure that the storage array status LED is blue. 3 Host server(s) Installing the Bezel Install the bezel (optional). Installing the MD Storage Software NOTE: For detailed instructions about installing the MD storage software, setting up the enclosure, and the post-installation tasks, see the Deployment Guide. The MD Storage Manager application configures, manages, and monitors the storage array.
2 Select Install MD Storage Software. 3 Read and accept the license agreement. 4 Select one of the following installation options from the Install Set drop-down menu: • Full (recommended)—Installs the MD Storage Manager (client) software, host-based storage agent, multipath driver, and hardware providers. • Host Only—Installs the host-based storage agent and multipath drivers. • Management—Installs the management software and hardware providers. • Custom—Allows you to select specific components.
Locating Your Service Tag Your system is identified by a unique Express Service Code and Service Tag number. The Express Service Code and Service Tag are found on the front of the system and at the back of the system next to the RAID controller modules. This information is used by Dell to route support calls to the appropriate personnel.
Technical Specifications Drives PowerVault MD3200 Up to twelve 3.5-inch SAS hot-swappable hard drives (3.0 Gbps and 6.0 Gbps) PowerVault MD3220 Up to twenty four 2.5-inch SAS hot-swappable hard drives (3.0 Gbps and 6.
Expansion PowerVault MD1200 series Supports a maximum of 192 hard drives with any combination of PowerVault MD1200 or PowerVault MD1220 expansion enclosures. Support for 192 hard drives is a Premium Feature and requires activation. The maximum number of hard drives supported without using the Premium Feature is 120. Redundant path connectivity provides redundant data paths to each hard drive.
LED Indicators (continued) RAID controller module Six single-color LEDs: • One battery fault • One cache active • One controller fault • One controller power • One system identification • One management Ethernet activity Six two-color LEDs: • Four SAS IN link or fault • One SAS OUT link or fault • One management Ethernet link speed Switch System identification button Located on the front control panel. This button is used to locate a system within a rack.
Available Hard Drive Power (Per Slot) PowerVault MD3200 25 W PowerVault MD3220 12 W RAID Controller Module Power (Per Slot) Maximum power consumption 100 W Physical PowerVault MD3200 Height 8.68 cm (3.41 inches) Width 44.63 cm (17.57 inches) Depth 60.20 cm (23.70 inches) Weight (maximum configuration) 29.30 kg (64.6 lb) Weight (empty) 8.84 kg (19.5 lb) PowerVault MD3220 Height 8.68 cm (3.41 inches) Width 44.63 cm (17.57 inches) Depth 54.90 cm (21.
Environmental NOTE: For additional information about environmental measurements for specific system configurations, see www.dell.com/environmental_datasheets. Temperature Operating 10 °C to 35 °C (50 °F to 95 °F) with a maximum temperature gradation of 10 °C per hour NOTE: For altitudes above 2950 feet, the maximum operating temperature is derated 1ºF/550 ft. Storage –40 °C to 65 °C (–40 °F to 149 °F) with a maximum temperature gradation of 20°C per hour.
Dell PowerVault MD3200 和 MD3220 存储阵列 系统使用入门 管制型号系列 E03J 和 E04J
注、小心和警告 注: “注”表示可以帮助您更好地使用计算机的重要信息。 小心: “小心”表示如果不遵循说明,就有可能损坏硬件或导致数据丢失。 警告: “警告”表示可能会导致财产损失、人身伤害甚至死亡。 ____________________ 本出版物中的信息如有更改,恕不另行通知。 © 2011 Dell Inc. 版权所有,翻印必究。 未经 Dell Inc. 书面许可,严禁以任何形式复制这些材料。 本文中使用的商标:Dell™ 、DELL 徽标、PowerVault™ 是 Dell Inc. 的商标。Microsoft® 和 Windows Server® 是 Microsoft Corporation 在美国和 / 或其他国家 / 地区的商标或注册商标。 Red Hat® 和 Red Hat Enterprise Linux® 是 Red Hat, Inc. 在美国和其他国家 / 地区的注册商标。 SUSE® 是 Novell, Inc. 在美国和其他国家或地区的注册商标。VMware® 是 VMware, Inc.
开始之前 注:在本说明文件中, Dell PowerVault MD3200 系列存储阵列指代 Dell PowerVault MD3200 和 Dell PowerVault MD3220。 Dell PowerVault MD1200 系列扩展柜指代 Dell PowerVault MD1200 和 Dell PowerVault MD1220。 在设置您的 Dell PowerVault MD3200 存储阵列之前,您必须考虑某些最佳 惯例以确保您的存储阵列以最高效率运作并提供完全冗余 (如果需要)。 • 在整个网络中,请始终使用 5e 类 (或更高)以太网电缆。 • 在主机服务器和存储阵列之间连接任何电缆之前,请物理地标签每个 端口和连接器。 • 当对整个网络通电时,请始终遵循正确的上电和断电步骤。您还必须 确保关键的网络组件位于单独的电源电路上。 您可能需要的其他说明文件和介质 警告:请参阅系统附带的安全与管制信息。保修信息可能包括在该说明文 件中,也可能作为单独的说明文件提供。 注:所有 PowerVault MD3200 系列说明文件均在 support.dell.
• 《SMI-S 程序员指南》提供了有关使用 SMI-S 提供程序和 SMI-S 编程 的信息。 • 系统随附的任何介质都提供了用于配置和管理系统的说明文件和工具, 包括随系统购买的操作系统、系统管理软件、系统更新以及系统组件 相关的说明文件和工具。 注:请经常访问 support.dell.com/manuals 以获得更新,并首先阅读这些 更新,因为这些更新通常会取代其他说明文件中的信息。 支持的操作系统 • Microsoft Windows Server • Red Hat Enterprise Linux • SUSE Linux Enterprise Server • VMware 注:有关所有受支持的操作系统版本的最新信息,请参阅 support.dell.
常见配置 为直接连接的主机布线 服务器 1 服务器 2 PowerVault MD3200 系列存储阵列 服务器 3 服务器 4 企业、公用或专 用网络 系统使用入门 21
安装和配置 警告:执行下列步骤之前,请查看系统随附的安全说明。 打开系统包装 打开系统包装并使用系统随附的包装清单识别每个物件。 在机架中安装滑轨和系统 遵循系统随附的安全说明和机架安装说明,在机架中组装滑轨并安装系统。 注:为了平衡重量负载,建议将 PowerVault MD3200 系列存储阵列安装在机 架底部,而将 PowerVault MD1200 系列扩展柜安装在其上方。 22 系统使用入门
连接电源电缆 在连接电源电缆之前,请确保电源开关处于 OFF (关闭)位置。将系统 的电源电缆连接到系统上。 固定电源电缆 使用提供的束带将电缆牢牢地固定在支架上。 将电源电缆的另一端插入接地的电源插座或单独的电源,如不间断电源设 备 (UPS) 或配电装置 (PDU)。每个电源都必须连接到单独的电源电路。 系统使用入门 23
为扩展柜布线 PowerVault MD1200 系 列扩展柜 2 (可选) PowerVault MD1200 系 列扩展柜 1 (可选) PowerVault MD3200 系列存储阵列 启动机柜 按以下顺序启动组件: 1 PowerVault MD1200 系列扩展柜 (如果使用) 注:在启动存储阵列之前,请确保扩展柜状态 LED 为蓝色。 24 系统使用入门
2 PowerVault MD3200 系列存储阵列 注:在启动主机服务器之前,请确保存储阵列状态 LED 为蓝色。 3 主机服务器 安装挡板 安装挡板 (可选)。 安装 MD 存储软件 注:有关安装 MD 存储软件、设置机柜和安装后任务的详细指导,请参阅 《部署指南》。 MD Storage Manager 应用程序配置、管理并监测存储阵列。要安装 MD 存储软件: 1 插入 MD 系列资源介质。 根据您的操作系统,安装程序可能会自动启动。如果安装程序没有自 动启动,请导航至安装介质 (或下载的安装程序映像)的根目录并运 行 md_launcher.
4 从 Install Set (安装集合)下拉菜单中选择以下一个安装选项: • Full (recommended) (完全 [ 建议 ])—安装 MD Storage Manager (客户端)软件、基于主机的存储代理、多路径驱动程序和硬件提 供程序。 • Host Only (仅主机)—安装基于主机的存储代理和多路径驱动 程序。 • Management (管理)—安装管理软件和硬件提供程序。 • Custom (自定义)—允许您选择具体组件。 5 选择您要设置用作此主机服务器数据存储的 MD 存储阵列型号。 6 选择在主机服务器重新启动或手动启动时,是否启动事件监控器服务 注:此选项只适用于 Windows 客户端软件安装。 7 确认安装位置并单击 Install (安装)。 8 在安装完成出现提示时,重新启动主机服务器。 9 启动 MD Storage Manager 并查找阵列。 10 如果适用,激活随存储阵列购买的所有高级功能。如果您购买了高级 功能,请参阅存储阵列随附的印刷激活卡。 注: MD Storage Manager 安装程序会自动安装需要的驱动程序、固件和操 作系统修
找到您的服务标签 您的系统由唯一的快速服务代码和服务标签号码进行标识。快速服务代 码和服务标签可在系统正面和系统背面 RAID 控制器模块旁边找到。 Dell 使用此信息将支持电话转接到适当的人员。 NOM 信息 (仅限于墨西哥) 本说明文件中述及的符合墨西哥官方标准 (NOM) 要求的设备上均提供以 下信息: 进口商: 型号: 电源电压: 频率: 电流消耗: E03J 和 E04J 100 – 240 V CA 50/60 Hz 8.
技术规格 驱动器 PowerVault MD3200 最多 12 个 3.5 英寸 SAS 可热交换 硬盘驱动器 (3.0 Gbps 和 6.0 Gbps) PowerVault MD3220 最多 20 个 2.5 英寸 SAS 可热交换 硬盘驱动器 (3.0 Gbps 和 6.0 Gbps) RAID 控制器模块 RAID 控制器模块 • 一个或两个带有温度传感器的可热交换模块 • 每个控制器有 2 GB 高速缓存 背面板连接器 (每个 RAID 控制器模块) SAS 接口 • 4 个 SAS IN 端口用于连接主机 • 1 个 SAS OUT 端口用于扩展到一个附加的 PowerVault MD1200 机柜 注:SAS 连接器与 SFF-8088 兼容。 串行连接器 一个 6 针小型 DIN 连接器 注:仅供技术支持使用。 管理以太网连接器 一个 100/1000 Base-T 端口以太网用于机柜的带外 管理 注:主和次 RAID 控制器模块的默认管理端口 IP 地址分别为 192.168.128.101 和 192.168.128.
扩展 PowerVault MD1200 系列 支持带有 PowerVault MD1200 或 PowerVault MD1220 扩展柜任意组合的最多 192 个硬盘驱动器。支持 192 个硬盘驱动器是一项高级功能,需要激活。不 使用高级功能支持的最大硬盘驱动器数为 120 个。 冗余路径连接性为每台硬盘驱动器提供冗余数据。 背板 连接器 • 12 个或 24 个 SAS 硬盘驱动器连接器 • 两个电源设备 / 冷却风扇模块连接器 • 两套 RAID 控制器模块连接器 • 一个控制面板连接器,用于正面 LED 指示灯和 系统识别按钮 传感器 两个温度传感器 LED 指示灯 前面板 • 一个双色 LED 指示灯,用于显示系统状态 • 两个单色 LED 指示灯,用于电源和机柜模式 注:机柜模式 LED 不适用于 PowerVault MD3200 系 列存储阵列。 硬盘驱动器托盘 • 一个单色活动 LED • 每个驱动器具有一个双色 LED 状态指示灯 电源设备 / 冷却风扇 三个 LED 状态指示灯,分别对应于电源设备状 态、电源设备 / 风扇故障和交流电状态 系统使用入门 29
LED 指示灯 (续) RAID 控制器模块 六个单色 LED 指示灯: • 一个指示电池故障 • 一个指示高速缓存活动 • 一个指示控制器故障 • 一个指示控制器电源 • 一个指示系统识别 • 一个指示管理以太网活动 六个双色 LED 指示灯: • 四个指示 SAS IN 链接或故障 • 一个指示 SAS OUT 链路或故障 • 一个指示管理以太网链接速度 开关 系统识别按钮, 位于前面控制面板。此按钮用于定位机架中的 系统。 机柜模式开关, 位于系统的正面。此开关不适用于 PowerVault MD3200 系列存储阵列。 密码重设开关, 位于 RAID 控制器模块的背面板。此开关用于重 设存储阵列密码。 电源 设备 交流电源设备 (每个电源设备) 30 功率 600 W 电压 100 – 240 VAC (8.6 A – 4.
可用的硬盘驱动器电源 (每个插槽) PowerVault MD3200 25 W PowerVault MD3220 12 W RAID 控制器模块电源 (每个插槽) 最大电源消耗 100 W 物理规格 PowerVault MD3200 高度 8.68 厘米 (3.41 英寸 ) 宽度 44.63 厘米 (17.57 英寸) 厚度 60.20 厘米 (23.70 英寸 ) 重量 (最大配置) 29.30 千克 (64.6 磅) 重量 (空置) 8.84 千克 (19.5 磅 ) PowerVault MD3220 高度 8.68 厘米 (3.41 英寸 ) 宽度 44.63 厘米 (17.57 英寸) 厚度 54.90 厘米 (21.61 英寸 ) 重量 (最大配置) 24.22 千克 (53.4 磅) 重量 (空置) 8.
环境参数 注:有关特定系统配置的环境测量值的附加信息,请参阅 www.dell.com/environmental_datasheets。 温度 运行时 10 °C 至 35 °C (50 °F 至 95 °F),最大温度 变化梯度为每小时 10 °C 注:海拔高度在 2950 英尺以上时,最高操作温度 按 1 °F/550 英尺降低。 Storage (存储) – 40 °C 至 65 °C (– 40 °F 至 149 °F),最 大温度变化梯度为每小时 20 °C 相对湿度 运行时 20% 到 80% (非冷凝),最大湿度变化梯度为每 小时 10% Storage (存储) 5% 至 95% (非冷凝) 最大振动 运行时 在 3 – 200 Hz、 0.25 G 时,可持续 15 分钟 Storage (存储) 在 3 – 200 Hz、 0.5 G 时,可持续 15 分钟 最大撞击 运行时 z 轴正方向上可承受一个 31 G 的撞击脉冲 (系统 每一面承受一个脉冲),在操作方向最多可持续 2.
Storage Array Dell PowerVault MD3200 dan MD3220 Memulai dengan Sistem Anda Model Resmi Seri E03J dan E04J
Catatan, Perhatian, dan Peringatan CATATAN: CATATAN menunjukkan informasi penting yang membantu Anda mengoptimalkan penggunaan komputer Anda. PERHATIAN: PERHATIAN menunjukkan kerusakan potensial pada perangkat keras atau kehilangan data jika Anda tidak mengikuti instruksi yang diberikan. PERINGATAN: PERINGATAN menunjukkan potensi terjadinya kerusakan properti, cedera pada seseorang, atau kematian. ____________________ Informasi dalam publikasi ini dapat berubah tanpa pemberitahuan. © 2011 Dell Inc.
Sebelum Anda Mulai CATATAN: Dalam keseluruhan dokumen, storage array Dell seri PowerVault MD3200 mengacu pada Dell PowerVault MD3200 dan Dell PowerVault MD3220. Expansion enclosure Dell seri PowerVault MD1200 mengacu pada Dell PowerVault MD1200 dan Dell PowerVault MD1220. Sebelum memasang storage array Dell seri PowerVault MD3200, Anda harus mempertimbangkan beberapa langkah terbaik agar storage array Anda beroperasi pada efisiensi maksimum dan menghasilkan redundansi penuh (jika diperlukan).
• Panduan Programer SMI-S menyediakan informasi mengenai cara menggunakan provider SMI-S dan pemrograman SMI-S. • Media apa pun yang dikirimkan bersama sistem Anda yang menyediakan dokumen dan peralatan untuk mengonfigurasi dan mengelola sistem, meliputi kaitannya dengan sistem pengoperasian, perangkat lunak manajemen sistem, update sistem, dan komponen sistem yang Anda beli dengan sistem Anda. CATATAN: Selalu periksa update di situs support.dell.
Konfigurasi Standar Mengatur Kabel Direct-Attached Host Anda Server 1 Server 2 Storage array seri PowerVault MD3200 Server 3 Server 4 Jaringan korporat, umum, atau pribadi Memulai Pengaktifan dengan Sistem Anda 37
Instalasi dan Konfigurasi PERINGATAN: Sebelum melakukan prosedur berikut, bacalah petunjuk keselamatan yang disertakan dengan sistem. Membuka Kemasan Sistem Keluarkan sistem Anda dan kenali setiap komponen dengan melihat daftar paket yang dikirimkan dengan sistem Anda. Memasang Rel dan Sistem dalam Rak Rakit rel dan pasang sistem dalam rak sesuai dengan petunjuk keselamatan dan petunjuk pemasangan rak yang disertakan bersama sistem Anda.
Menyambungkan Kabel Daya Pastikan bahwa switch daya dalam posisi OFF sebelum menyambungkan kabel daya. Sambungkan kabel daya sistem ke sistem. Menahan Kabel Daya Ikatkan kabel dengan kencang pada braket dengan menggunakan strap yang disediakan. Sambungkan ujung lain kabel daya ke outlet listrik dengan koneksi ground atau sumber daya terpisah seperti catu daya bebas gangguan (uninterrupted power supply/UPS) atau unit distribusi daya (power distribution unit/PDU).
Mengatur Kabel Expansion Enclosure Anda Expansion enclosure 2 seri PowerVault MD1200 (opsional) Expansion enclosure 1 seri PowerVault MD1200 (opsional) Storage array seri PowerVault MD3200 Mengaktifkan Enclosure Aktifkan komponen-komponen dengan urutan berikut: 1 Expansion enclosure seri PowerVault MD1200 (jika digunakan) CATATAN: Sebelum mengaktifkan storage array, pastikan LED status expansion enclosure menyala biru.
2 Storage array seri PowerVault MD3200 CATATAN: Sebelum mengaktifkan host server, pastikan LED status storage array menyala biru. 3 Host server Memasang Bezel Pasang bezel (opsional). Menginstal Perangkat Lunak MD Storage CATATAN: Untuk instruksi lebih detail mengenai penginstalan perangkat lunak MD storage, memasang enclosure, dan langkah-langkah pasca-instalasi, lihat Panduan Penggunaan. Aplikasi MD Storage Manager mengonfigurasi, mengelola, dan memonitor storage array.
CATATAN: Red Hat Enterprise Linux sejak awal sudah memasukkan opsi noexec mount pada media sumber yang tidak mengizinkan Anda menjalankan file executable. Untuk mengubah pengaturan ini, lihat file Readme pada direktori akar dari media instalasi. 2 Pilih Install MD Storage Software (Instal Perangkat Lunak Penyimpanan MD). 3 Bacalah dan terima perjanjian lisensi.
CATATAN: Installer MD Storage Manager secara otomatis menginstal patch/hotfix driver, firmware, dan sistem pengoperasian yang diperlukan untuk mengoperasikan storage array Anda. Driver dan firmware ini juga tersedia di situs support.dell.com. Selain itu, lihat Support Matrix di situs support.dell.com/manuals untuk pengaturan tambahan apa pun dan/atau perangkat lunak yang diperlukan untuk storage array tertentu Anda.
Informasi NOM (Hanya Meksiko) Informasi berikut disediakan pada perangkat yang dijelaskan dalam dokumen ini sesuai dengan persyaratan mengenai standar resmi Meksiko (NOM): Importir: Nomor model: Tegangan suplai: Frekuensi: Konsumsi arus: E03J dan E04J 100–240 V CA 50/60 Hz 8,6 A Spesifikasi Teknis Drive PowerVault MD3200 Hingga dua belas hot-swappable hard drive SAS 3,5-inci (3,0 Gbps dan 6,0 Gbps) PowerVault MD3220 Hingga dua puluh empat hot-swappable hard drive SAS 2,5-inci (3,0 Gbps dan 6,0 Gbps)
Konektor Panel Belakang (per Modul Kontroler RAID) Konektor SAS • Empat port SAS IN untuk menghubungkan host • Satu port SAS OUT untuk ekspansi ke enclosure PowerVault MD1200 tambahan CATATAN: Konektor SAS kompatibel untuk SFF-8088. Konektor serial Satu konektor 6-pin mini-DIN CATATAN: Hanya untuk dukungan teknis.
Papan Backplane Konektor • 12 atau 24 konektor hard drive SAS • Dua konektor catu daya/modul kipas pendingin • Dua unit konektor modul kontroler RAID • Satu konektor panel kontrol untuk LED depan dan tombol identifikasi sistem Sensor Dua sensor suhu Indikator LED Panel depan • Satu indikator LED dua warna untuk status sistem • Dua indikator LED satu warna untuk mode daya dan mode enclosure CATATAN: LED mode enclosure tidak berlaku untuk storage array seri PowerVault MD3200.
Switch Tombol identifikasi sistem Terletak di panel kontrol depan. Tombol ini digunakan untuk menemukan sistem dalam rak. Switch mode enclosure Berada di bagian depan sistem. Switch ini tidak berlaku untuk storage array seri PowerVault MD3200. Switch reset password Berada di panel belakang modul kontroler RAID. Switch ini digunakan untuk mereset password storage array.
Fisik (dilanjutkan) Berat (konfigurasi maksimum) 29,30 kg (64,6 pon) Berat (kosong) 8,84 kg (19,5 pon) PowerVault MD3220 Tinggi 8,68 cm (3,41 inci) Lebar 44,63 cm (17,57 inci) Panjang 54,90 cm (21,61 inci) Berat (konfigurasi maksimum) 24,22 kg (53,4 pon) Berat (kosong) 8,61 kg (19 pon) Lingkungan CATATAN: Untuk informasi tambahan mengenai pengukuran lingkungan untuk konfigurasi sistem spesifik, lihat www.dell.com/environmental_datasheets.
Lingkungan (dilanjutkan) Pengoperasian Satu pulsasi guncangan pada sumbu z positif (satu pulsasi pada setiap sisi sistem) dari 31 G untuk 2,6 mdet dalam arah pengoperasian Penyimpanan Enam pulsasi guncangan yang dilakukan berurutan pada sumbu x, y, dan z positif dan negatif (satu pulsasi di setiap sisi sistem) dari 71 G selama hingga 2 mdet Ketinggian Pengoperasian –16 hingga 3.048 m (–50 hingga 10.000 kaki) CATATAN: Untuk ketinggian di atas 2.
50 Memulai Pengaktifan dengan Sistem Anda
Dell PowerVault MD3200 および MD3220 ストレージアレイ はじめに 規制モデルシリーズ E03J および E04J
メモ、注意、警告 メモ : コンピュータを使いやすくするための重要な情報を説明しています。 注意 : 手順に従わないと、ハードウェアの損傷やデータの損失につながる可能性が あることを示しています。 警告: 物的損害、けが、または死亡の原因となる可能性があることを示し ています。 ____________________ 本書の内容は予告なく変更されることがあります。 © 2011 すべての著作権は Dell Inc. にあります。 Dell Inc. の書面による許可のない複製は、いかなる形態においても厳重に禁じられています。 本書に使用されている商標:Dell™、DELL のロゴ、および PowerVault™ は Dell Inc. の商標です。 Microsoft® および Windows Server® は米国およびその他の国における Microsoft Corporation の商標ま たは登録商標です。Red Hat® および Red Hat Enterprise Linux® は、米国およびその他の国における Red Hat, Inc.
作業を開始する前に メモ : 本書において、Dell PowerVault MD3200 シリーズストレージアレイとは Dell PowerVault MD3200 および Dell PowerVault MD3220 の両方を指します。 Dell PowerVault MD1200 シリーズ拡張エンクロージャとは Dell PowerVault MD1200 および Dell PowerVault MD1220 の両方を指します。 Dell PowerVault MD3200 シリーズストレージアレイをセットアップする前に、 特定のベストプラクティスを考慮して、ご使用のストレージアレイが最高の効率 で動作し、完全な冗長性(必要な場合)が提供されることを確認することが必要 です。 • ネットワーク全体を通して、常にカテゴリ 5e(またはそれ以上)のイーサ ネットケーブルを使用します。 • ホストサーバーとストレージアレイ間のケーブルを接続する前に、各ポート およびコネクタにラベルを貼っておきます。 • ネットワーク全体で動力サイクルをする場合、常に正しいパワーアップとパ ワーダウンの手順に従いま
メモ : アップデートには他の文書の内容を差し替える情報が含まれている場合 がよくありますので、support.dell.com/manuals でアップデートがないか どうかを常に確認し、初めにお読みください。 対応オペレーティングシステム • • • • Microsoft Windows Server Red Hat Enterprise Linux SUSE Linux Enterprise Server VMware メモ : サポートされる、すべてのオペレーティングシステムバージョンの最新情報 は、support.dell.
取り付けと設定 警告:次の手順を実行する前に、システムに付属しているマニュアルの 「安全にお使いいただくために」をお読みください。 システムの開梱 システムを開梱して、システムに同梱の納品書リストと照らし合わせながら、各 アイテムを確認します。 ラックへのレールとシステムの取り付け レールの組み立てとラックへのシステムの取り付けの際は、システムに付属して いるマニュアルの「安全にお使いいただくために」およびラックへの取り付け手 順に従ってください。 メモ : 重量負荷のバランスを取るため、PowerVault MD3200 シリーズストレージ アレイをラックの最下位置に取り付け、その上に PowerVault MD1200 シリーズ拡 張エンクロージャを取り付けることをお勧めします。 はじめに 55
電源ケーブルの接続 電源ケーブルを接続する前に、電源スイッチがオフになっていることを確認して ください。システムに電源コードを接続します。 電源ケーブルの固定 同梱のストラップでケーブルをブラケットにしっかりと固定します。 電源ケーブルのもう一方の端をアースされた電源コンセントまたは UPS(無停電 電源装置)や配電装置(PDU)などの電源に接続します。各電源装置は別々の電 気回路に接続します。 56 はじめに
拡張エンクロージャの配線 PowerVault MD1200 シ リーズ拡張エンクロー ジャ 2(オプション) PowerVault MD1200 シ リーズ拡張エンクロー ジャ 1(オプション) PowerVault MD3200 シ リーズストレージアレイ エンクロージャへの電源投入 次の順序でコンポーネントに電源を入れます。 1 PowerVault MD1200 シリーズ拡張エンクロージャ(使用する場合) メモ : ストレージアレイに電源を入れる前に、拡張エンクロージャステータス LED が青色であることを確認します。 はじめに 57
2 PowerVault MD3200 シリーズストレージアレイ メモ : RAID エンクロージャーに電源を入れる前に、RAID エンクロージャス 3 ホストサーバー テータス LED が青色であることを確認します。 ベゼルの取り付け ベゼルを取り付けます(オプション)。 MD ストレージソフトウェアのインストール メモ : MD ストレージソフトウェアのインストール、エンクロージャのセットアッ プ、およびインストール後のタスクに関する詳細手順は『導入ガイド』を参照して ください。 MD ストレージ管理アプリケーションは、ストレージアレイを設定、管理、およ び監視します。MD ストレージソフトウェアをインストールするには、次の手順 を実行します。 1 MD シリーズリソースメディアを挿入します。 お使いのオペレーティングシステムによっては、インストーラが自動的に起 動する場合があります。インストーラーが自動的に起動しない場合は、イン ストールメディア(またはダウンロードしたインストーライメージ)のルー トディレクトリに移動し、md_launcher.
メモ : Red Hat Enterprise Linux オペレーティングシステムは、デフォルトで リソースメディアを –noexec mount オプションでマウントします。このオ プションでは実行可能ファイルを実行できません。この設定を変更するには、 インストールメディアのルートディレクトリにある readme ファイルを参照 してください。 2 MD Storage ソフトウェアのインストール を選択します。 3 ライセンス契約を読み、それに合意します。 4 インストール設定 ドロップダウンメニューから、次のインストールオプ ションのいずれかを選択します。 • 完全(推奨)— MD Storage Manager(クライアント)ソフトウェ ア、ホストベースのストレージエージェント、マルチパスドライバ、お よびハードウェアプロバイダをインストールします。 • ホストのみ — ホストベースのストレージエージェントおよびマルチパ スドライバをインストールします。 • 管理 — 管理ソフトウェアおよびハードウェアプロバイダをインストー ルします。 • カスタム — 特定のコンポー
サービスタグの位置 お使いのシステムは固有のエクスプレスサービスコードとサービスタグ番号で識 別されます。エクスプレスサービスコードおよびサービスタグは、システムの前 面およびシステムの背面の RAID コントローラモジュール横にあります。この情 報は、デルが受けたサポート宛ての電話を、適切な担当者に転送するために使用 されます。 NOM 情報(メキシコのみ) 次の情報は、メキシコの公式規格(NOM)の要件に従い、本書で取り上げている 装置に関して提供されています。 輸入者: モデル番号: 供給電圧: 周波数: 消費電流: 60 はじめに E03J および E04J 100 ~ 240 V CA 50/60 Hz 8.
仕様 ドライブ PowerVault MD3200 最大 12 台のホットスワップ対応 3.5 インチ SAS ハー ドディスクドライブ(3.0 Gbps および 6.0 Gbps) PowerVault MD3220 最大 24 台のホットスワップ対応 2.5 インチ SAS ハー ドディスクドライブ(3.0 Gbps および 6.
バックプレーンボード コネクタ • • • • センサー 12 または 24 SAS ハードディスクドライブコネクタ 電源装置 / 冷却ファンモジュールのコネクタ 2 個 RAID コントローラモジュールコネクタ 2 セット 前面 LED およびシステム識別ボタン用コントロール パネルコネクタ 1 個 温度センサー 2 個 LED インジケータ フロントパネル • システムスの状態を示す 2 色の LED インジケータ 1個 • 電源とエンクロージャモード用の単色 LED インジ ケータ 2 個 メモ : エンクロージャモード LED は PowerVault MD3200 シリーズストレージアレイには適用されま せん。 ハードディスクドライブキャ リア • 単色のアクティビティ LED 1 個 • 各ドライブにつき 2 色の LED ステータスインジケー タ1個 電源装置 / 冷却ファンの障害 電源装置のステータス、電源装置 / ファン障害、およ び AC のステータスを示す LED ステータスインジ ケータ 3 個 RAID コントローラモジュール 単色 LED 6 個 : • バ
スイッチ システム識別ボタン 前面コントロールパネル上にあります。このボタンは、 ラック内でのシステムの位置確認に使用されます。 エンクロージャモードスイッチ システムの前面にあります。このスイッチは PowerVault MD3200 シリーズストレージアレイに は適用されません。 パスワードリセットスイッチ RAID コントローラモジュールの背面パネルにありま す。このスイッチはストレージアレイパスワードのリ セットに使用します。 電源 装置 AC 電源装置(各電源装置につき) ワット数 600 W 電圧 100 ~ 240 VAC(8.6 A ~ 4.
サイズと重量 (続き) 横幅 44.63 cm 奥行き 54.90 cm 重量(最大構成) 24.22 kg 重量(空の状態) 8.61 kg 環境 メモ : 特定のシステム構成でのその他の環境条件の詳細については、 www.dell.com/environmental_datasheets を参照してください。 温度 動作時 1 時間当たり最大 10°C の温度変化で 10 ~ 35°C メモ : 高度が 2950 フィートを超えると、動作時の許容 最大温度は、550 フィーとごとに 1 °F ずつ低下します。 保管時 1 時間当たり最大 20°C の温度変化で -40 ~ 65°C 相対湿度 動作時 1 時間当たり最大 10 パーセントの湿度変化で 20 ~ 80%(結露しないこと) 保管時 5 ~ 95 パーセント(結露しないこと) 最大振動 動作時 15 分間にわたり 3-200 Hz で 0.25 G 保管時 15 分間にわたり 3-200 Hz で 0.5 G 最大衝撃 動作時 z 軸の正方向に 2.
Dell PowerVault MD3200 및 MD3220 스토리지 배열 시스템 시작 안내서 정규 모델 시리즈 E03J 및 E04J
주 , 주의 및 경고 주 : " 주 " 는 컴퓨터를 보다 효율적으로 사용하는 데 도움을 주는 중요 정보를 나타냅니다 . 주의 : " 주의 " 는 지침을 준수하지 않을 경우의 하드웨어 손상이나 데이터 손 실 위험을 설명합니다 . 경고 : " 경고 " 는 재산상의 피해나 심각한 부상 또는 사망을 유발할 수 있는 위험이 있음을 알려줍니다 . ____________________ 이 발행물에 수록된 정보는 사전 통보 없이 변경될 수 있습니다 . © 2011 Dell Inc. 저작권 본사 소유 . Dell Inc. 의 서면 승인 없이 어떠한 방식으로든 본 자료를 무단 복제하는 행위는 엄격히 금지 됩니다 . 본 문서에 사용된 상표인 Dell™, DELL 로고 , 및 PowerVault™ 는 Dell Inc. 의 상표입니다 . Microsoft® 및 Windows Server® 는 미국 및 기타 국가에서 Microsoft Corporation 의 상표 또는 등록상표입니다 .
시작하기 전에 주 : 본 설명서의 Dell PowerVault MD3200 시리즈 스토리지 배열은 Dell PowerVault MD3200 및 Dell PowerVault MD3220 을 의미합니다 . Dell PowerVault MD1200 시리즈 확장 인클로저는 Dell PowerVault MD1200 및 Dell PowerVault MD1220 을 의미합니다 . Dell PowerVault MD3200 시리즈 스토리지 배열을 설치하기에 앞서 특정 모범사례를 참조하여 스토리지 배열이 최대 효율 상태에서 작동하고 ( 필요한 경우 ) 완전 중복성을 제공할 수 있도록 해야 합니다 . • 네트워크에서는 반드시 Category 5e ( 이상의 ) 이더넷 케이블을 사용하 십시오 . • 호스트 서버와 스토리지 배열 간에 케이블을 연결하기 전에 , 각각의 포 트와 커넥터에 물리적으로 라벨을 부착하십시오 . • 네트워크에서 전원을 순환시킬 경우 반드시 올바른 전원 켜기 및 전원 끄기 절차를 따르십시오 .
• 운영 체제, 시스템 관리 소프트웨어, 시스템 업데이트 및 시스템과 함께 구입한 시스템 구성요소와 관련된 설명서 및 도구를 비롯하여 시스템 을 구성 및 관리하는 데 필요한 설명서 및 도구를 제공하는 모든 매체가 시스템과 함께 제공됩니다 . 주 : 새로운 업데이트가 없는지 support.dell.com/manuals 에서 항상 확인 하십시오 . 업데이트에는 최신 정보가 수록되어 있으므로 다른 문서를 읽기 전에 반드시 먼저 참조하시기 바랍니다 . 지원되는 운영 체제 • Microsoft Windows Server • Red Hat Enterprise Linux • SUSE LINUX Enterprise Server • VMware 주 : 지원되는 모든 운영 체제 버전에 관한 최신 정보는 support.dell.com/manuals 에서 Support Matrix ( 지원 매트릭스 ) 를 참조하십시오 .
일반구성 직접 연결 호스트의 케이블 연결 서버 1 서버 2 서버 3 PowerVault MD3200 시리즈 스토리지 배열 서버 4 회사 , 공용 또는 개인 네트워크 시스템 시작 안내서 69
설치 및 구성 경고 : 다음 절차를 수행하기 전에 시스템과 함께 제공되는 안전 지침을 검토 하십시오 . 시스템 포장 풀기 시스템의 포장을 풀고 시스템과 함께 제공된 포장 리스트와 각각의 항목을 비교하여 확인합니다 . 랙에 레일 및 시스템 설치 시스템과 함께 제공되는 안전 지침 및 랙 설치 지침에 따라 레일을 조립하 고 시스템을 랙에 설치합니다 . 주 : 무게 하중의 균형을 잡으려면 , 랙 하단에 PowerVault MD3200 시리즈 스토 리지 배열을 설치하고 그 위에 PowerVault MD1200 시리즈 확장 인클로저를 설 치하는 것이 좋습니다 .
전원 케이블 연결 전원 케이블을 연결하기 전에 전원 스위치가 꺼짐 (OFF) 위치에 있는지 확인하십시오 . 시스템의 전원 케이블을 시스템에 연결합니다 . 전원 케이블 고정 제공된 스트랩을 사용하여 케이블을 브래킷에 단단히 고정합니다 . 전원 케이블의 반대쪽 끝을 접지된 전원 콘센트나 UPS( 무정전 전원 공급 장치 ) 또는 PDU( 배전 장치 ) 와 같은 별도의 전원에 연결합니다 . 각각의 전원 공급 장치는 개별 전원 회로에 연결해야 합니다 .
확장 인클로저의 케이블 연결 PowerVault MD1200 시리즈 확장 인클로 저 2 ( 선택사양 ) PowerVault MD1200 시리즈 확장 인클로 저 1 ( 선택사양 ) PowerVault MD3200 시리즈 스토리지 배열 인클로저 켜기 다음의 순서대로 구성요소를 켜십시오 : 1 ( 사용하는 경우 ) PowerVault MD1200 시리즈 확장 인클로저 . 주 : 스토리지 배열의 전원을 켜기 전에 , 확장 인클로저 상태 LED 가 파란색인지 확인하십시오 .
2 PowerVault MD3200 시리즈 스토리지 배열 . 주 : 호스트 서버의 전원을 켜기 전에 , 스토리지 배열 상태 LED 가 파란 색인지 확인하십시오 . 3 호스트 서버 . 베젤 설치 베젤 ( 선택 사양 ) 을 설치합니다 . MD 스토리지 소프트웨어 설치 주 : MD 스토리지 소프트웨어 설치 , 인클로저 설치 , 설치후 작업에 관한 자세 한 설명은 Deployment Guide( 배치 안내서 ) 를 참조하십시오 . MD 스토리지 관리자 응용프로그램은 스토리지 배열을 구성 , 관리 , 모니 터합니다 . MD 스토리지 소프트웨어를 설치하려면 : 1 MD 시리즈 자원 매체를 삽입합니다 . 운영 체제에 따라 , 설치 프로그램이 자동으로 시작될 수 있습니다 . 설 치 프로그램이 자동으로 시작되지 않으면 , 설치 매체 ( 또는 다운로드된 설치 프로그램 이미지 ) 의 루트 디렉터리를 탐색하고 md_launcher.exe 파일을 실행합니다 .
2 Install MD Storage Software(MD 스토리지 소프트웨어 설치 ) 를 선택합 니다 . 3 사용 계약서를 읽은 다음 , 승인하십시오 . 4 Install Set( 설치 세트 ) 드롭다운 메뉴에서 다음의 설치 옵션 중 하나를 선택합니다 : • Full( 전체 ( 권장 )) — MD Storage Manager ( 클라이언트 ) 소프트웨 어 , 호스트 기반 스토리지 에이전트 , 다중경로 드라이버 , 하드웨 어 프로바이더를 설치합니다 . • Host Only( 호스트만 ) — 호스트 기반 스토리지 에이전트와 다중경 로 드라이버를 설치합니다 . • Management(관리) — 관리 소프트웨어 및 하드웨어 프로바이더를 설치합니다 . • Custom( 사용자 정의 ) — 특정 구성요소를 선택할 수 있습니다 . 5 이 호스트 서버를 위한 데이터 스토리지로서 역할을 수행하도록 하려 면 설치중인 MD 스토리지 배열 모델을 선택합니다 .
서비스 태그 찾기 사용자의 시스템은 고유한 특급 서비스 코드 및 서비스 태그 번호로 식별 됩니다 . 특급 서비스 코드와 서비스 태그는 시스템 전면과 RAID 컨트롤러 모듈 옆의 시스템 후면에서 확인할 수 있습니다 . 이 정보는 Dell 에서 적절 한 직원과 지원 통화를 구성할 경우 사용됩니다 . NOM 정보 ( 멕시코에만 해당 ) 다음 정보는 멕시코 표준 규격 (NOM) 의 요구 사항을 준수하는 본 문서에 기술된 장치에 대한 내용입니다 . 수입업체 : 모델 번호 : 공급 전압 : 주파수 : 전류 소모량 : E03J 및 E04J 100 ~ 240V CA 50/60Hz 8.
기술 사양 드라이브 PowerVault MD3200 최대 12 개의 3.5 인치 SAS 핫스왑 가능 하드 드라이브 (3.0 Gbps 및 6.0 Gbps) PowerVault MD3220 최대 24 개의 2.5 인치 SAS 핫스왑 가능 하드 드라이브 (3.0 Gbps 및 6.0 Gbps) RAID 컨트롤러 모듈 RAID 컨트롤러 모듈 • 온도 센서가 부착된 핫스왑이 가능한 모듈 1 개 또는 2 개 • 컨트롤러 당 2 GB 의 캐시 후면 패널 커넥터 (RAID 컨트롤러 모듈 당 ) SAS 커넥터 • 호스트 연결을 위한 SAS 입력 포트 4 개 • 추가적인 PowerVault MD1200 시리즈 인클로저 에 대한 확장용 SAS 출력 포트 1 개 주 : SAS 커넥터는 SFF-8088 을 준수합니다 . 직렬 커넥터 6 핀 미니 DIN 커넥터 1 개 주 : 기술 지원 사용 전용 .
확장 PowerVault MD1200 시리즈 PowerVault MD1200 또는 PowerVault MD1220 확 장 인클로저의 조합에 의해 최대 192 개의 하드 드 라이브를 지원합니다 192 개의 하드 드라이브에 대한 지원은 고급 기능으로 활성화가 필요합니다. 고급 기능을 사용하지 않고 지원되는 최대 하드 드 라이브 수는 120 입니다 . 중복 경로 연결성은 각각의 하드 드라이브에 대한 중복 데이터 경로를 제공합니다 .
LED 표시등 ( 계속 ) RAID 컨트롤러 모듈 단색 LED 6 개 : • 전지 결함 표시용 1 개 • 캐시 활성화 표시용 1 개 • 컨트롤러 결함 표시용 1 개 • 컨트롤러 전원 표시용 1 개 • 시스템 확인용 1 개 • 관리 이더넷 작동 표시용 1 개 2- 색 LED 6 개 : • SAS 입력 링크 또는 결함 표시용 4 개 • SAS 출력 링크 또는 결함 표시용 1 개 • 관리 이더넷 링크 속도 표시용 1 개 스위치 시스템 확인 단추 전면 제어판에 있음 . 이 단추는 랙에서 시스템의 위치를 확인하는데 사용됩니다 . 인클로저 모드 스위치 시스템의 전면에 위치함 . 본 스위치는 PowerVault MD3200 시리즈 스토리지 배열에 적용할 수 없습 니다 . 암호 재설정 스위치 RAID 컨트롤러 모듈의 후면 패널에 위치함 . 이 스 위치는 스토리지 배열 암호 재설정에 사용됩니다 .
사용 가능한 하드 드라이브 전원 ( 슬롯당 ) PowerVault MD3200 25 W PowerVault MD3220 12 W RAID 컨트롤러 모듈 전원 ( 슬롯당 ) 최대 소비 전력 100 W 실제 PowerVault MD3200 높이 8.68 cm (3.41 인치 ) 너비 44.63cm (17.57 인치 ) 깊이 60.20 cm (23.70 인치 ) 무게 ( 최대 구성 시 ) 29.30 kg (64.6 lb) 무게 ( 비어 있을 경우 ) 8.84 kg (19.5 lb) PowerVault MD3220 높이 8.68 cm (3.41 인치 ) 너비 44.63 cm (17.57 인치 ) 깊이 54.90 cm (21.61 인치 ) 무게 ( 최대 구성 시 ) 24.22 kg (53.4 lb) 무게 ( 비어 있을 경우 ) 8.
환경적 특성 주 : 특정 시스템 구성을 위한 환경 측정에 대한 자세한 내용은 www.dell.com/environmental_datasheets 를 참조하십시오 . 온도 작동 10 °C ~ 35 °C (50 °F ~ 95 °F), 시간당 최고 10 °C 의 온도 변화 기준 주 : 2,950 피트 이상의 고도인 경우 최대 작동 온도 는 1 °F/550ft 로 감소됩니다 . 보관 –40 °C ~ 65 °C (–40 °F ~ 149 °F), 시간당 최고 20 °C 의 온도 변화 기준 상대 습도 작동 20% ~ 80%( 비응축 ), 시간당 최고 10% 의 습도 변 화 기준 보관 5 ~ 95%( 비응축 ) 최대 진동 작동 3 ~ 200Hz 에서 15 분간 0.25G 보관 3 ~ 200Hz 에서 15 분간 0.5G 최대 충격 작동 작동 방향으로 2.
Printed in China. Dicetak di China. Printed on Recycled Paper. w w w. d e l l . c o m | s u p p o r t . d e l l .
Printed in Malaysia. Dicetak di Malaysia. w w w. d e l l . c o m | s u p p o r t . d e l l .