Setup Guide
Table Of Contents
- Getting Started With Your System
- Getting Started With Your System
- Before You Begin
- Other Documentation and Media You May Need
- Supported Operating Systems
- Common Configurations
- Installation and Configuration
- Unpacking the System
- Installing the Rails and System in a Rack
- Connecting the Power Cable(s)
- Securing the Power Cable(s)
- Installing and Removing SFP Modules
- Installing and Removing Fibre Channel Cables
- Cabling Your Expansion Enclosure
- Turning On the Storage Array
- Installing the Bezel
- Installing HBAs and Drivers
- Installing the MD Storage Software
- Locating Your Service Tag
- NOM Information (Mexico Only)
- Technical Specifications
- 系统使用入门
- Memulai Pengaktifan dengan Sistem Anda
- Sebelum Anda Mulai
- Dokumen dan Media Lain yang Mungkin Anda Butuhkan
- Sistem Pengoperasian yang Didukung
- Konfigurasi Standar
- Instalasi dan Konfigurasi
- Membuka Kemasan Sistem
- Memasang Rel dan Sistem dalam Rak
- Menyambungkan Kabel Daya
- Menahan Kabel Daya
- Memasang dan Melepaskan Modul SFP
- Memasang dan Melepaskan Kabel Fibre Channel
- Mengatur Kabel Expansion Enclosure Anda
- Mengaktifkan Storage Array
- Memasang Bezel
- Memasang HBA dan Driver
- Menginstal Perangkat Lunak MD Storage
- Menemukan Tag Servis Anda
- Informasi NOM (Hanya Meksiko)
- Spesifikasi Teknis
- はじめに
- 시스템 시작 안내서

Getting Started With Your System
17
Management Ethernet
connector
One 100/1000 Base-T port Ethernet for out-of-band
management of the enclosure
NOTE:
The default management port IP addresses for
the primary and secondary RAID controller modules
are 192.168.128.101 and 192.168.128.102, respectively.
By default, the management ports are set to DHCP.
If the controller is unable to get an IP address
configuration from a DHCP server within a specified
time out period (approximately 3 minutes), it defaults
back to static IP addressing. For more information,
see the Deployment Guide.
Expansion
PowerVault MD1200 series Supports a maximum of 192 hard drives with any
combination of PowerVault MD1200 or PowerVault
MD1220 expansion enclosures. Support for 192 hard
drives is a Premium Feature and requires activation.
The maximum number of hard drives supported
without using the Premium Feature is 120.
Redundant path connectivity provides redundant
data paths to each hard drive.
Backplane Board
Connectors
• 12 or 24 SAS hard-drive connectors
• Two power supply/cooling fan module connectors
• Two sets of RAID controller module connectors
• One control panel connector for front LEDs and
system identification button
Sensors Two temperature sensors
Back-Panel Connectors (Per RAID Controller Module) (continued)