Dell PowerVault MD3600i and MD3620i Storage Arrays Getting Started With Your System 系统使用入门 Memulai Pengaktifan dengan Sistem Anda はじめに 시스템 시작 안내서
Dell PowerVault MD3600i and MD3620i Storage Arrays Getting Started With Your System Regulatory Model Series E03J and E04J
Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. ____________________ Information in this publication is subject to change without notice. © 2011 Dell Inc. All rights reserved.
Before You Begin NOTE: Throughout the document, Dell PowerVault MD3600i series storage array refers to both Dell PowerVault MD3600i and Dell PowerVault MD3620i. Dell PowerVault MD1200 series expansion enclosure refers to both Dell PowerVault MD1200 and Dell PowerVault MD1220. Before setting up your Dell PowerVault MD3600i series storage array, you must consider certain best practices to ensure that your storage array operates at maximum efficiency and offers full redundancy (if required).
• If multiple NICs are installed on a host, it is recommeded that you use different subnets for management and iSCSI data links. • Before connecting any cables between the host server and storage array, physically label each port and connector. • Always follow proper power-up and power-down procedures when cycling power across the network. You must also ensure that critical network components are on separate power circuits.
Completing the iSCSI Worksheet IPv4 Settings A host server 192.168.131.101 (In 1 default) 192.168.130.101 (In 0 default) Mutual CHAP Secret 192.168.128.101 (management network port) PowerVault MD3600i series storage array B Target CHAP Secret 192.168.130.102 (In 0 default) 192.168.131.102 (In 1 default) 192.168.128.102 (management network port) If you need additional space for more than one host server, use an additional sheet.
NOTE: For information about the IPv6 worksheet, see the Deployment Guide. Other Documentation and Media You May Need WARNING: See the safety and regulatory information that shipped with your system. Warranty information may be included within this document or as a separate document. NOTE: All PowerVault MD3600i series storage array documents are available at support.dell.com/manuals. • The rack documentation included with your rack solution describes how to install your system into a rack.
Preparing the Host Server Supported Operating Systems • Microsoft Windows Server • Red Hat Enterprise Linux • SUSE Linux Enterprise Server • VMware NOTE: For the latest information on all supported operating system versions, see the Support Matrix at support.dell.com/manuals. Additional NICs for iSCSI When installing additional NICs, it is recommended that: • You use dedicated redundant storage networks for iSCSI traffic.
Common Configurations Cabling Your SAN-Attached Hosts Connect all cables between the servers, switches, and storage arrays as shown in the following illustration. For more examples of cabling the storage arrays, see the Deployment Guide at support.dell.com/manuals.
Cabling Your Direct-Attached Hosts Server 1 Server 2 Storage array Corporate, public, or private network Getting Started With Your System 9
Installation and Configuration WARNING: Before performing the following procedure, review the safety instructions that came with the system. Unpacking the System Unpack your system and identify each item with the packing list that shipped with your system. Installing the Rails and System in a Rack Assemble the rails and install the system in the rack following the safety instructions and the rack installation instructions provided with your system.
Connecting the Power Cable(s) Ensure that the power switch is in the OFF position before connecting the power cables. Connect the system’s power cable(s) to the system. Securing the Power Cable(s) Secure the cable(s) firmly to the bracket using the provided strap. Plug the other end of the power cable(s) into a grounded electrical outlet or a separate power source such as an uninterrupted power supply (UPS) or a power distribution unit (PDU).
Cabling Your Expansion Enclosure PowerVault MD1200 series expansion enclosure 2 (optional) PowerVault MD1200 series expansion enclosure 1 (optional) PowerVault MD3600i series storage array Turning On the Enclosure Turn on components in the following order 1 Ethernet switches (if used) 2 PowerVault MD1200 series expansion enclosures (if used) NOTE: Before turning on the storage array, ensure that the expansion enclosure status LED on the front of the enclosure is blue.
4 Host server(s) Installing the Bezel Install the bezel (optional).
Installing the MD Storage Software NOTE: For detailed instructions about installing the MD storage software, setting up the enclosure, and the post-installation tasks, see the Deployment Guide. The MD Storage Manager software configures, manages and monitors the storage array. The MD Configuration Utility (MDCU) is an optional utility that provides a consolidated approach for configuring the management and iSCSI host ports, and creating sessions for the iSCSI modular disk storage arrays.
5 Select the MD storage array model(s) you are setting up to serve as data storage for this host server. 6 Choose whether to start the event monitor service automatically when the host server reboots or manually NOTE: This option is applicable only to Windows client software installation. 7 Confirm the installation location and click Install. 8 If prompted, reboot the host server after the installation completes. 9 When the reboot is complete, the MDCU may launch automatically.
Locating Your Service Tag Your system is identified by a unique Express Service Code and Service Tag number. The Express Service Code and Service Tag are found on the front of the system and at the back of the system next to the RAID controller modules. This information is used by Dell to route support calls to the appropriate personnel.
Technical Specifications Drives PowerVault MD3600i Up to twelve 3.5-inch SAS hot-swappable hard drives (3.0 Gbps and 6.0 Gbps) PowerVault MD3620i Up to twenty four 2.5-inch SAS hot-swappable hard drives (3.0 Gbps and 6.
Expansion PowerVault MD1200 series Supports a maximum of 192 hard drives with any combination of PowerVault MD1200 or PowerVault MD1220 expansion enclosures. Support for 192 hard drives is a Premium Feature and requires activation. The maximum number of hard drives supported without using the Premium Feature is 120. Redundant path connectivity provides redundant data paths to each hard drive.
LED Indicators (continued) RAID controller module Eight single-color LEDs: • One battery fault • One cache active • One controller fault • One controller power • One system identification • One management Ethernet activity • Two iSCSI IN port activity Four two-color LEDs: • Two iSCSI IN link speed • One SAS OUT link or fault • One management Ethernet link speed Switch System identification button Located on the front control panel. This button is used to locate a system within a rack.
Available Hard-Drive Power (Per Slot) PowerVault MD3600i 25 W PowerVault MD3620i 12 W RAID Controller Module Power (Per Slot) Maximum power consumption 100 W Physical PowerVault MD3600i Height 8.68 cm (3.41 inches) Width 44.63 cm (17.57 inches) Depth 60.20 cm (23.70 inches) Weight (maximum configuration) 29.30 kg (64.6 lb) Weight (empty) 8.84 kg (19.5 lb) PowerVault MD3620i Height 8.68 cm (3.41 inches) Width 44.63 cm (17.57 inches) Depth 54.90 cm (21.
Environmental (continued) Storage –40° to 65°C (–40° to 149°F) with a maximum temperature gradation of 20°C per hour Relative humidity Operating 20% to 80% (noncondensing) with a maximum humidity gradation of 10% per hour Storage 5% to 95% (noncondensing) Maximum vibration Operating 0.25 G at 3–200 Hz for 15 min Storage 0.5 G at 3–200 Hz for 15 min Maximum shock Operating One shock pulse in the positive z axis (one pulse on each side of the system) of 31 G for 2.
22 Getting Started With Your System
Dell PowerVault MD3600i 和 MD3620i 存储阵列 系统使用入门 管制型号系列 E03J 和 E04J
注、小心和警告 注:“注”表示可以帮助您更好地使用计算机的重要信息。 小心:“小心”表示如果不遵循说明,就有可能损坏硬件或导致数据丢失。 警告:“警告”表示可能会导致财产损失、人身伤害甚至死亡。 ____________________ 本出版物中的信息如有更改,恕不另行通知。 © 2011 Dell Inc. 版权所有,翻印必究。 未经 Dell Inc. 书面许可,严禁以任何形式复制这些材料。 本文中使用的商标:Dell™ 、 DELL 徽标和 PowerVault™ 是 Dell Inc. 的商标。 Microsoft® 和 Windows Server® 是 Microsoft Corporation 在美国和 / 或其他国家或地区的商标或注册商标。 Red Hat® 和 Red Hat Enterprise Linux® 是 Red Hat, Inc. 在美国和其他国家或地区的注册商标。 SUSE® 是 Novell, Inc. 在美国和其他国家或地区的注册商标。VMware® 是 VMware, Inc.
开始之前 注:在本说明文件中, Dell PowerVault MD3600i 系列存储阵列指代 Dell PowerVault MD3600i 和 Dell PowerVault MD3620i。 Dell PowerVault MD1200 系列 扩展柜指代 Dell PowerVault MD1200 和 Dell PowerVault MD1220.
完成 iSCSI 工作表 IPv4 设置 A 主机服务器 交互 CHAP 机密 192.168.128.101 (管理网络端口) 192.168.131.101 (In [ 输入 ] 1 默认值) 192.168.130.101 (In [ 输入 ] 0 默认值) PowerVault MD3600f 系列存储阵列 B 目标 CHAP 机密 192.168.130.102 (In [ 输入 ] 0 默认值) 192.168.131.102 (In [ 输入 ] 1 默认值) 192.168.128.102 (管理网络端口) 如果您需要将更多空间用于多台主机服务器,请使用附加表。 注 : 质询握手身份验证协议 (CHAP) 是一种可选的 iSCSI 身份验证方法,存储阵列 (目标) 通过此方法对主机服务器上的 iSCSI 启动程序进行身份验证。有关详情,请参阅 《部署指 南》中的 “了解 CHAP 验证”。 A 静态 IP 地址 (主机服务器) 默认网关 iSCSI 端口 0 ___ .___ .___ .___ ___ .___ .___ .___ ___ .___ .
注:有关 IPv6 工作表的信息,请参阅 《部署指南》。 您可能需要的其他说明文件和介质 警告:请参阅系统附带的安全与管制信息。保修信息可能包括在该说明文 件中,也可能作为单独的说明文件提供。 注:所有 PowerVault MD3600i 系列说明文件均在 support.dell.com/manuals 提供。 • 机架解决方案附带机架说明文件,介绍了如何将系统安装到机架中。 • 《用户手册》提供了有关系统功能的信息,并说明了如何排除系统故障 以及安装或更换系统组件。 • 《部署指南》提供了有关安装和配置软件与硬件的信息。 • 《CLI 指南》提供了有关使用命令行界面 (CLI)配置和管理存储阵列 的信息。 • 《SMI-S 提供程序安装指南》提供了有关安装 SMI-S 提供程序的信息。 • 系统随附的任何介质,其中提供了用于配置和管理系统的说明文件和 工具,包括与系统预装的操作系统、系统管理软件、系统更新以及系 统组件相关的说明文件和工具。 注:请经常访问 support.dell.
准备主机服务器 支持的操作系统 • Microsoft Windows Server • Red Hat Enterprise Linux • SUSE Linux Enterprise Server • VMware 注:关于所有支持的操作系统版本的最新信息,请参见 support.dell.
常见配置 为 SAN 方式连接的主机布线 按照下面插图中所示,连接服务器、交换机和存储阵列之间的所有电缆。 有关为存储阵列布线的更多示例,请参阅 support.dell.
为直接连接的主机布线 服务器 1 服务器 2 存储阵列 企业、公用或 专用网络 30 系统使用入门
安装和配置 警告:执行下列步骤之前,请查看系统随附的安全说明。 打开系统包装 打开系统包装并使用系统随附的包装清单识别每个物件。 在机架中安装滑轨和系统 遵循系统随附的安全说明和机架安装说明,在机架中组装滑轨并安装系统。 注:为了平衡重量负载,建议将 PowerVault MD3600i 系列存储阵列安装在机 架底部,而将 PowerVault MD1200 扩展柜安装在其上方。 系统使用入门 31
连接电源电缆 在连接电源电缆之前,请确保电源开关处于 OFF (关闭)位置。将系统 的电源电缆连接到系统上。 固定电源电缆 使用提供的束带将电缆牢牢地固定在支架上。 将电源电缆的另一端插入接地的电源插座或单独的电源,如不间断电源设 备 (UPS) 或配电装置 (PDU)。每个电源都必须连接到单独的电源电路。 32 系统使用入门
为扩展柜布线 PowerVault MD1200 系列扩展柜 2 (可选) PowerVault MD1200 系列扩展柜 1 (可选) PowerVault MD3600i 系列存储阵列 启动机柜 以下列顺序打开各部件的电源 以太网交换机 (若使用) 2 PowerVault MD1200 series expansion enclosures (if used) 1 注:在开启存储阵列之前,请确保扩展柜正面的扩展柜状态 LED 指示 灯显示为蓝色。 3 PowerVault MD3600i 系列存储阵列 注:在开启主机服务器之前,请确保存储阵列正面的存储阵列状态 LED 指示灯显示为蓝色。 系统使用入门 33
4 主机服务器 安装挡板 安装挡板 (可选)。 34 系统使用入门
安装 MD 存储软件 注:有关安装 MD 存储软件,设置硬盘柜,以及安装后的任务,请参阅 《部署指南》。 MD Storage Manager 软件配置、管理并监测存储阵列。MD Configuration Utility (MDCU) 是一个可选实用程序,它提供了配置管理和 iSCSI 主机端 口,以及为 iSCSI 模块磁盘存储阵列创建会话的一致途径。建议使用 MDCU 配置连接到存储阵列的每台主机服务器上的 iSCSI。要安装 MD 存储软件: 1 插入 MD 系列资源介质。 根据操作系统,安装程序可能会自动启动。如果安装程序未自动启动, 请导航至安装介质 (或下载的安装程序映像)的根目录并运行 md_launcher.
9 重新引导完成时, MDCU 会自动启动。如果 MDCU 未自动启动,请 手动启动。 • 在基于 Windows 的操作系统中,单击开始 → Dell→ Modular Disk Configuration Utility。 • 在基于 Linux 的操作系统中,双击桌面上的 Modular Disk Configuration Utility 图标。 注:如果 MDCU 未安装,请参阅 support.dell.com/manuals 上的 《部署指南》。 10 启动 MD Storage Manager 并查找阵列。 11 如果适用,激活随存储阵列购买的任何高级功能。如果购买了高级功 能,请参阅存储阵列附带的印刷激活卡。 注:MD Storage Manager 安装程序会自动安装所需的驱动程序、固件和操作 系统修补程序 / 热补丁,以操作存储阵列。这些驱动程序和固件也可从 support.dell.com 上获取。另外,请参阅 support.dell.
找到您的服务标签 您的系统由唯一的快速服务代码和服务标签号码进行标识。“快速服务码” 和 “服务标签号”标在系统的正面及系统背面的 RAID 控制器模块旁。 Dell 使用此信息将支持电话转接到适当的人员。 NOM 信息 (仅限于墨西哥) 本说明文件中述及的符合墨西哥官方标准 (NOM) 要求的设备上均提供以 下信息: 进口商: 型号: 电源电压: 频率: 电流消耗: E03J 和 E04J 100 – 240 V CA 50/60 Hz 8.
技术规格 驱动器 PowerVault MD3600i 至多 12 个 3.5 英寸 SAS 可热交换的硬盘驱 动器 (3.0 Gbps 和 6.0 Gbps) PowerVault MD3620i 至多 24 个 2.5 英寸 SAS 可热交换的硬盘驱 动器 (3.0 Gbps 和 6.0 Gbps) RAID 控制器模块 RAID 控制器模块 • 具备温度传感器的一两个热交换模块 • 每个控制器有 2 GB 高速缓存 背面板连接器 (每个 RAID 控制器模块) iSCSI 连接器 两个连接到主机的 10 GB iSCSI IN 连接器 SAS 扩展连接器 一个用于扩展到附加的 PowerVault MD12xx 硬盘柜的 SAS OUT 端口。 注:SAS 连接器与 SFF-8088 兼容。 串行连接器 一个 6 针小型 DIN 连接器 注:仅供技术支持使用。 管理以太网连接器 38 系统使用入门 一个 100/1000 Base-T 端口以太网用于机柜 的带外管理 注:主要和次要 RAID 控制器模块的默认管 理端口 IP 地址分别是 192.168.128.
扩展 PowerVault MD1200 series 支持带有 PowerVault MD1200 或 PowerVault MD1220 扩展柜任意组合的最多 96 个硬盘 驱动器。支持 192 个硬盘驱动器的是高级 功能,并且需要激活。不使用高级功能时 所能支持的最多硬盘驱动器数是 120。 冗余路径连接性为每台硬盘驱动器提供冗 余数据。 背板 连接器 • 12 个或 24 个 SAS 硬盘驱动器连接器 • 两个电源设备 / 冷却风扇模块连接器 • 两套 RAID 控制器模块连接器 • 一个用于前面 LED 的控制面板连接器和 硬盘柜模式开关 传感器 两个温度传感器 LED 指示灯 前面板 • 一个双色 LED 指示灯,用于显示系 统状态 • 两个单色 LED 指示灯,用于电源和 机柜模式 注:机柜模式 LED 不适用于 PowerVault MD3600i 系列存储阵列。 硬盘驱动器托盘 • 一个单色活动 LED • 每个驱动器具有一个双色 LED 状态 指示灯 电源设备 / 冷却风扇 三个 LED 状态指示灯,分别对应于电源设 备状态、电源设备 / 风扇故障和交流电状态 系统
LED 指示灯 (续) RAID 控制器模块 八个单色 LED 指示灯: • 一个指示电池故障 • 一个指示高速缓存活动 • 一个指示控制器故障 • 一个指示控制器电源 • 一个指示系统识别 • 一个指示管理以太网活动 • 两个指示 iSCSI IN 端口活动 四个双色 LED 指示灯: • 两个指示 iSCSI IN 链路速度 • 一个指示 SAS OUT 链路或故障 • 一个指示管理以太网链接速度 开关 系统识别按钮, 位于前面控制面板。此按钮用于定位机架 中的系统。 机柜模式开关, 位于系统的正面。此开关不适用于 PowerVault MD3600i 系列存储阵列。 密码重设开关, 位于 RAID 控制器后面板上。此开关用于重 设存储阵列密码。 电源 设备 交流电源设备 (每个电源设备) 40 功率 600 W 电压 100 – 240 VAC (8.6 A – 4.
可用的硬盘驱动器电源 (每个插槽) PowerVault MD3600i 25 W PowerVault MD3620i 12 W RAID 控制器模块电源 (每个插槽) 最大电源消耗 100 W 物理规格 PowerVault MD3600i 高度 8.68 厘米 (3.41 英寸 ) 宽度 44.63 厘米 (17.57 英寸) 厚度 60.20 厘米 (23.70 英寸 ) 重量 (最大配置) 29.30 千克 (64.6 磅) 重量 (空置) 8.84 千克 (19.5 磅 ) PowerVault MD3620i 高度 8.68 厘米 (3.41 英寸 ) 宽度 44.63 厘米 (17.57 英寸) 厚度 54.90 厘米 (21.61 英寸 ) 重量 (最大配置) 24.2 千克 (53.4 磅) 重量 (空置) 8.61 千克 (19 磅 ) 环境参数 注:有关特定系统配置的环境测量值的附加信息,请参阅 www.dell.
环境参数 (续) 运行时 20% 到 80% (非冷凝),最大湿度变化梯 度为每小时 10% Storage (存储) 5% 至 95% (非冷凝) 最大振动 运行时 在 3 – 200 Hz、 0.25 G 时,可持续 15 分钟 Storage (存储) 在 3 – 200 Hz、 0.5 G 时,可持续 15 分钟 最大撞击 运行时 轴正方向上可承受一个 31 G 的撞击脉冲 (系统每一面承受一个脉冲),在操作方向 最多可持续 2.6 毫秒 Storage (存储) x、 y 和 z 轴正负方向上可承受连续六 个 71 G 的撞击脉冲 (系统每一面承受一个 脉冲),最长可持续 2 毫秒 海拔高度 运行时 – 16 至 3048 米 (– 50 至 10,000 英尺) 注:海拔高度在 2950 英尺以上时,最高操 作温度按 1°F/550 英尺降低。 Storage (存储) – 16 到 10,600 米 (– 50 到 35,000 英尺) 气载污染物级别 级别 42 G1 (依据 ISA-S71.
Storage Array Dell PowerVault MD3600i dan MD3620i Memulai Pengaktifan dengan Sistem Anda Model Resmi Seri E03J dan E04J
Catatan, Perhatian, dan Peringatan CATATAN: CATATAN menunjukkan informasi penting yang membantu Anda untuk menggunakan komputer dengan lebih baik. PERHATIAN: PERHATIAN menunjukkan kerusakan potensial pada perangkat keras atau kehilangan data jika Anda tidak mengikuti instruksi yang diberikan. PERINGATAN: PERINGATAN menunjukkan kemungkinan kerusakan pada harta benda, cedera diri, atau kematian. ____________________ Informasi dalam publikasi ini dapat berubah tanpa pemberitahuan. © 2011 Dell Inc.
Sebelum Anda Mulai CATATAN: Dalam keseluruhan dokumen, storage array Dell seri PowerVault MD3600i mengacu pada Dell PowerVault MD3600i dan Dell PowerVault MD3620i. Expansion enclosure Dell seri PowerVault MD1200 mengacu pada Dell PowerVault MD1200 dan Dell PowerVault MD1220. Sebelum memasang storage array Dell seri PowerVault MD3600i, Anda harus mempertimbangkan beberapa langkah terbaik agar storage array Anda beroperasi pada efisiensi maksimum dan menghasilkan redundansi penuh (jika diperlukan).
• Jika beberapa NIC diinstal pada sebuah host, Anda disarankan untuk menggunakan subnet yang berbeda untuk manajemen dan link data iSCSI. • Sebelum menyambungkan kabel apapun antara host server dan storage array, berikan label pada setiap port dan konektor. • Selalu lakukan prosedur power-up dan power-down saat mengedarkan daya di seluruh jaringan. Anda juga harus memastikan komponen jaringan penting memiliki sirkuit daya terpisah.
Menyelesaikan Lembar Kerja iSCSI Pengaturan IPv4 A host server Mutual CHAP Secret 192.168.128.101 (port jaringan manajemen) 192.168.131.101 (In 1 default) 192.168.130.101 (In 0 default) Storage array seri PowerVault MD3600i B Target CHAP Secret 192.168.130.102 (In 0 default) 192.168.131.102 (In 1 default) 192.168.128.102 (port jaringan manajemen) Jika Anda memerlukan ruang tambahan untuk lebih dari satu host server, gunakan lembar tambahan.
CATATAN: Untuk informasi mengenai lembar kerja IPv6, lihat Panduan Penggunaan. Dokumen dan Media Lain yang Mungkin Anda Butuhkan PERINGATAN: Lihat informasi keselamatan dan peraturan yang dikirimkan bersama dengan sistem Anda. Informasi garansi mungkin disertakan dalam dokumen ini atau sebagai dokumen yang terpisah. CATATAN: Semua dokumen storage array seri PowerVault MD3600i terdapat di situs support.dell.com/manuals.
Mempersiapkan Host Server Sistem Operasi yang Didukung • Microsoft Windows Server • Red Hat Enterprise Linux • SUSE Linux Enterprise Server • VMware CATATAN: Untuk informasi terbaru mengenai versi sistem pengoperasian yang didukung, lihat Support Matrix di situs support.dell.com/manuals. NIC tambahan untuk iSCSI Saat memasang NIC tambahan, Anda disarankan untuk: • Menggunakan jaringan penyimpanan redundan khusus untuk lalu lintas iSCSI.
Konfigurasi Standar Mengatur Kabel SAN-Attached Host Anda Sambungkan semua kabel antara server, switch, dan storage array, seperti yang diperlihatkan dalam ilustrasi berikut ini. Untuk contoh perkabelan storage array, bacalah Panduan Penggunaan di situs support.dell.com/manuals.
Mengatur Kabel Direct-Attached Host Anda Server 1 Server 2 Storage array Jaringan korporat, umum, atau pribadi Memulai Pengaktifan dengan Sistem Anda 51
Instalasi dan Konfigurasi PERINGATAN: Sebelum melakukan prosedur berikut, bacalah petunjuk keselamatan yang disertakan dengan sistem. Membuka Kemasan Sistem Keluarkan sistem Anda dan kenali setiap komponen dengan melihat daftar paket yang dikirimkan dengan sistem Anda. Memasang Rel dan Sistem dalam Rak Rakit rel dan pasang sistem dalam rak sesuai dengan petunjuk keselamatan dan petunjuk pemasangan rak yang disertakan bersama sistem Anda.
Menyambungkan Kabel Daya Pastikan bahwa switch daya dalam posisi OFF sebelum menyambungkan kabel daya. Sambungkan kabel daya sistem ke sistem. Menahan Kabel Daya Ikatkan kabel dengan kencang pada braket dengan menggunakan strap yang disediakan. Sambungkan ujung lain kabel daya ke outlet listrik dengan koneksi ground atau sumber daya terpisah seperti catu daya bebas gangguan (uninterrupted power supply/UPS) atau unit distribusi daya (power distribution unit/PDU).
Mengatur Kabel Expansion Enclosure Anda Expansion enclosure 2 seri PowerVault MD1200 (opsional) Expansion enclosure 1 seri PowerVault MD1200 (opsional) Storage array seri PowerVault MD3600i Mengaktifkan Enclosure Aktifkan komponen dalam urutan berikut 1 Saklar Ethernet (jika digunakan) 2 Expansion enclosure seri PowerVault MD1200 (jika digunakan) CATATAN: Sebelum mengaktifkan storage array, pastikan bahwa LED status expansion enclosure di bagian depan menyala biru.
4 Host server Memasang Bezel Pasang bezel (opsional).
Menginstal Perangkat Lunak MD Storage CATATAN: Untuk instruksi lebih detail mengenai penginstalan perangkat lunak MD storage, memasang enclosure, dan langkah-langkah pasca-instalasi, lihat Panduan Penggunaan. Perangkat lunak MD Storage Manager mengonfigurasikan, mengelola, dan memonitor storage array. MD Configuration Utility (MDCU) merupakan utilitas opsional yang menyediakan pendekatan konsolidasi untuk mengonfigurasi port host iSCSI dan manajemen, dan membuat sesi untuk iSCSI modular disk storage array.
5 Pilih storage array MD yang Anda atur untuk dijadikan penyimpanan data untuk server host ini. 6 Pilih untuk memulai layanan monitor peristiwa secara otomatis ketika server host melakukan booting ulang atau secara manual CATATAN: Opsi ini hanya berlaku pada instalasi perangkat lunak klien Windows. 7 Konfirmasikan lokasi instalasi dan klik Install (Instal). 8 Jika diperintahkan, lakukan booting ulang server host setelah instalasi selesai. 9 Ketika booting ulang selesai, MDCU dapat berjalan secara otomatis.
Menemukan Tag Servis Anda Sistem Anda diidentifikasi melalui Kode Servis Ekspres dan nomor Tag Servis yang unik. Kode Servis Ekspres dan Tag Servis berada di bagian depan sistem dan di bagian belakang sistem di samping modul kontroler RAID. Informasi ini digunakan oleh Dell untuk menghubungkan panggilan dukungan ke personel yang sesuai.
Spesifikasi Teknis Drive PowerVault MD3600i Hingga dua belas hot-swappable hard drive SAS 3,5-inci (3,0 Gbps dan 6,0 Gbps) PowerVault MD3620i Hingga dua puluh empat hot-swappable hard drive SAS 2,5-inci (3,0 Gbps dan 6,0 Gbps) Modul Kontroler RAID Modul kontroler RAID • Satu atau dua hot-swappable module dengan sensor suhu • 2 GB cache per kontroler Konektor Panel Belakang (per Modul Kontroler RAID) konektor iSCSI Dua konektor iSCSI IN 10 GB untuk menyambungkan host Konektor ekspansi SAS Satu port
Ekspansi Seri PowerVault MD1200 Mendukung maksimum 192 hard drive dengan kombinasi manapun dari expansion enclosure PowerVault MD1200 atau PowerVault MD1220. Mendukung untuk 192 hard drive adalah Fitur Premium dan membutuhkan aktivasi. Jumlah maksimum hard drive yang didukung tanpa menggunakan Fitur Premium adalah 120. Konektivitas alur redundan menyediakan alur data redundan untuk setiap hard drive.
Indikator LED (dilanjutkan) Modul kontroler RAID Delapan LED berwarna tunggal: • Satu gangguan baterai • Satu cache active • Satu gangguan kontroler • Satu daya kontroler • Satu identifikasi sistem • Satu aktivitas Ethernet manajemen • Dua aktivitas port iSCSI IN Dua LED warna ganda: • Dua kecepatan link iSCSI IN • Satu link atau gangguan SAS OUT • Satu kecepatan link Ethernet manajemen Switch Tombol identifikasi sistem Terletak di panel kontrol depan.
Tersedia Daya Hard Drive (Per Slot) PowerVault MD3600i 25 W PowerVault MD3620i 12 W Daya Modul Kontroler RAID (Per Slot) Konsumsi daya maksimum 100 W Fisik PowerVault MD3600i Tinggi 8,68 cm (3,41 inci) Lebar 44,63 cm (17,57 inci) Panjang 60,20 cm (23,70 inci) Berat (konfigurasi maksimum) 29,30 kg (64,6 pon) Berat (kosong) 8,84 kg (19,5 pon) PowerVault MD3620i Tinggi 8,68 cm (3,41 inci) Lebar 44,63 cm (17,57 inci) Panjang 54,90 cm (21,61 inci) Berat (konfigurasi maksimum) 24,2 kg (53,4
Lingkungan (dilanjutkan) Kelembapan relatif Pengoperasian 20% hingga 80% (nonkondensasi) dengan gradasi kelembapan maksimum dari 10% per jam Penyimpanan 5% hingga 95% (nonkondensasi) Getaran maksimum Pengoperasian 0,25 G pada 3–200 Hz selama 15 menit Penyimpanan 0,5 G pada 3–200 Hz selama 15 menit Guncangan maksimum Pengoperasian Satu pulsasi guncangan pada sumbu z positif (satu pulsasi pada setiap sisi sistem) dari 31 G untuk 2,6 mdet dalam arah pengoperasian Penyimpanan Enam pulsasi guncangan y
64 Memulai Pengaktifan dengan Sistem Anda
Dell PowerVault MD3600i および MD3620i ストレージアレイ はじめに 規制モデルシリーズ E03J および E04J
メモ、注意、警告 メモ : コンピュータを使いやすくするための重要な情報を説明しています。 注意 : 手順に従わないと、ハードウェアの損傷やデータの損失につながる可能性が あることを示しています。 警告: 物的損害、けが、または死亡の原因となる可能性があることを示し ています。 ____________________ 本書の内容は予告なく変更されることがあります。 © 2011 すべての著作権は Dell Inc. にあります。 Dell Inc. の書面による許可のない複製は、いかなる形態においても厳重に禁じられています。 本書で使用されている商標について:Dell™、DELL のロゴ、および PowerVault™ は Dell Inc. の商標 です。Microsoft® および Windows Server® は、米国および / またはその他の国々における Microsoft Corporation の商標または登録商標です。Red Hat® および Red Hat Enterprise Linux® は米国およびそ の他の国々における Red Hat, Inc.
作業を開始する前に メモ : 本書において、Dell PowerVault MD3600i シリーズストレージアレイとは Dell PowerVault MD3600i および Dell PowerVault MD3620i の両方を指します。 Dell PowerVault MD1200 シリーズ拡張エンクロージャとは Dell PowerVault MD1200 および Dell PowerVault MD1220 の両方を指します。 Dell PowerVault MD3600i ストレージアレイをセットアップする前に、特定の ベストプラクティスを考慮して、RAID エンクロージャが最高の効率で動作し、 完全な冗長性(必要な場合)が提供されることを確認することが必要です。 • PowerVault MD3600i シリーズストレージアレイは、カテゴリ 6 またはそれ以上のケーブル、10GBase-T 対応パッチパネル、およびス イッチで構成された 10GBase-T 対応インフラストラクチャが必要な 10GBase-T 製品です。 • 既存の 1GBase-T インフラストラクチャは、10G
• ネットワーク全体で動力サイクルをする場合、常に正しいパワーアップとパ ワーダウンの手順に従います。また、重要なネットワークコンポーネントは 別々の電源回路に置くようにします。 メモ : この文書の図では、SAN 環境での PowerVault MD3600i ストレージアレイ 1 つのみの配線を示しています。また、この図は PowerVault MD3600i ストレージ アレイのデフォルト IP アドレスのみを示しています。SAN 環境で複数の PowerVault MD3600i ストレージアレイを配線する場合は、『導入ガイド』を参照 してください。 68 はじめに
iSCSI ワークシートの完了 IPv4 の設定 A ホストサーバー 192.168.131.101 (デフォルトは In 1) 相互 CHAP シークレット 192.168.128.101 (管理ネットワークポート) 192.168.130.101 (デフォルトは In 0) PowerVault MD3600i シ リーズストレージアレイ ターゲット CHAP シーク レット B 192.168.130.102 (デフォルトは In 0) 192.168.131.102 (デフォルトは In 1) 192.168.128.
メモ : IPv6 ワークシートに関する情報は、『導入ガイド』を参照してください。 必要なその他のマニュアルおよびメディア 警告:システムに付属のマニュアルで 安全および認可に関する情報 を参 照してください。保証に関する情報は、このマニュアルに含まれている場 合と、別の文書として付属されている場合があります。 メモ : PowerVault MD3600i シリーズストレージアレイのマニュアルは、すべて support.dell.
ホストサーバーの準備 対応オペレーティングシステム • Microsoft Windows Server • Red Hat Enterprise Linux • SUSE Linux Enterprise Server • VMware メモ : サポートされる、すべてのオペレーティングシステムバージョンの最新情報 は、support.dell.
一般的な設定 SAN 接続ホストの配線 サーバー、スイッチ、およびストレージアレイ間のすべてのケーブルは、次の図 のにあるように接続してください。ストレージアレイの配線の追加例は、 support.dell.
直接接続ホストの配線 サーバー 1 サーバー 2 ストレージアレイ 企業、パブリック、 またはプライベート ネットワーク はじめに 73
取り付けと設定 警告:次の手順を実行する前に、システムに付属しているマニュアルの 「安全にお使いいただくために」をお読みください。 システムの開梱 システムを開梱して、システムに同梱の納品書リストと照らし合わせながら、各 アイテムを確認します。 ラックへのレールとシステムの取り付け レールの組み立てとラックへのシステムの取り付けの際は、システムに付属して いるマニュアルの「安全にお使いいただくために」およびラックへの取り付け手 順に従ってください。 メモ : 重量負荷のバランスを取るため、PowerVault MD3600i シリーズストレージ アレイをラックの最下位置に取り付け、その上に PowerVault MD1200 シリーズ拡 張エンクロージャを取り付けることをお勧めします。 74 はじめに
電源ケーブルの接続 電源ケーブルを接続する前に、電源スイッチがオフになっていることを確認して ください。システムに電源コードを接続します。 電源ケーブルの固定 同梱のストラップでケーブルをブラケットにしっかりと固定します。 電源ケーブルのもう一方の端をアースされたコンセントまたは無停電電源装置 (UPS)や配電装置(PDU)などの別の電源に接続します。各電源装置は別々の電 気回路に接続します。 はじめに 75
拡張エンクロージャの配線 PowerVault MD1200 シ リーズ拡張エンクロー ジャ 2(オプション) PowerVault MD1200 シ リーズ拡張エンクロー ジャ 1(オプション) PowerVault MD3600i シ リーズストレージアレイ エンクロージャへの電源投入 次の順序でコンポーネントに電源を入れます。 1 イーサネットスイッチ(使用する場合) 2 PowerVault MD1200 シリーズ拡張エンクロージャ(使用する場合) メモ : ストレージアレイに電源を投入する前に、エンクロージャ前面にある エンクロージャステータス LED が青色であることを確認してください。 3 PowerVault MD3600i シリーズストレージアレイ メモ : ホストサーバーに電源を投入する前に、ストレージアレイ前面にある ストレージアレイステータス LED が青色であることを確認してください。 76 はじめに
4 ホストサーバー ベゼルの取り付け ベゼルを取り付けます(オプション)。 はじめに 77
MD ストレージソフトウェアのインストール メモ : MD ストレージソフトウェアのインストール、エンクロージャのセットアッ プ、およびインストール後のタスクに関する詳細手順は『導入ガイド』を参照して ください。 MD Storage Manager ソフトウェアは、ストレージアレイを設定、管理、およ び監視します。MD 設定ユーティリティ(MDCU)は管理ポート、iSCSI ホスト ポートの設定、および iSCSI モジュラーディスクストレージアレイ用セッション の作成に、集約された手段を提供するオプションのユーティリティです。スト レージアレイに接続された各ホストサーバーの iSCSI を設定するには、MDCU を 使用することをお勧めします。MD ストレージソフトウェアをインストールする には、次の手順を実行します。 1 MD シリーズリソースメディアを挿入します。 お使いのオペレーティングシステムによっては、インストーラが自動的に起 動する場合があります。インストーラーが自動的に起動しない場合は、イン ストールメディア(またはダウンロードしたインストーライメージ)のルー トディレクトリに移動し
5 このホストサーバー用のデータストレージとして機能するようにセットアッ プしている MD ストレージアレイのモデルを選択します。 6 イベント監視サービスを、ホストサーバーの再起動時に自動で開始するか、 手動で開始するかを選択します。 メモ : このオプションは、Windows クライアントソフトウェアのインストー ルに限り適用可能です。 7 インストール先を確認して、インストール をクリックします。 8 インストールの完了後、プロンプト表示に従ってホストサーバーを再起動し ます。 9 再起動が完了したら、MDCU が自動で起動します。MDCU が自動で起動し ない場合は、手動で起動してください。 • • Windows ベースのオペレーティングシステムでは、スタート → Dell → Modular Disk 設定ユーティリティ とクリックします。 Linux ベースのオペレーティングシステムでは、デスクトップの Modular Disk 設定ユーティリティ アイコンをダブルクリックします。 メモ : MDCU がインストールされない場合は、 support.dell.
サービスタグの位置 お使いのシステムは固有のエクスプレスサービスコードとサービスタグ番号で識 別されます。エクスプレスサービスコードおよびサービスタグは、システムの前 面およびシステムの背面の RAID コントローラモジュール横にあります。この情 報は、デルが受けたサポート宛ての電話を、適切な担当者に転送するために使用 されます。 NOM 情報(メキシコのみ) 次の情報は、メキシコの公式規格(NOM)の要件に従い、本書で取り上げている 装置に関して提供されています。 輸入者: モデル番号: 供給電圧: 周波数: 消費電流: 80 はじめに E03J および E04J 100 ~ 240 V CA 50/60 Hz 8.
仕様 ドライブ PowerVault MD3600i 3.5 インチ、ホットスワップ対応 SAS ハード ディスクドライブ(3.0 Gbps および 6.0 Gbps) 最高 12 台 PowerVault MD3620i 2.5 インチ、ホットスワップ対応 SAS ハード ディスクドライブ(3.0 Gbps および 6.
拡張 PowerVault MD1200 シリーズ PowerVault MD1200 または PowerVault MD1220 拡張エンクロージャのどの組み合わ せでも最大 192 台のハードディスクドライブ をサポートします。192 台のハードディスクド ライブのサポートはプレミアム機能で、機能の アクティブ化が必要です。プレミアム機能を使 用せずにサポートできるハードディスクドライ ブの最大数は 120 台です。 冗長パス接続性は、各ハードディスクドライブ に冗長データパスを提供します。 バックプレーンボード コネクタ • 12 または 24 SAS ハードディスクドライブコ ネクタ • 電源装置 / 冷却ファンモジュールのコネクタ 2個 • RAID コントローラモジュールコネクタ 2 セット • 前面 LED とエンクロージャモードスイッチ用 のコントロールパネルコネクタ 1 個 センサー 温度センサー 2 個 LED インジケータ フロントパネル • システムスの状態を示す 2 色の LED インジ ケータ 1 個 • 電源とエンクロージャモード用の単色 LED イ ンジケータ
LED インジケータ (続き) RAID コントローラモジュール 単色 LED 8 個 • バッテリ障害 1 個 • キャッシュアクティブ 1 個 • コントローラ障害 1 個 • コントローラ電源 1 個 • システム識別 1 個 • 管理イーサネットアクティビティ 1 個 • iSCSI IN ポートアクティビティ 2 個 2 色 LED 4 個 • iSCSI IN リンクスピード 2 個 • SAS OUT リンクまたは障害 1 個 • 管理イーサネットリンクスピード 1 個 スイッチ システム識別ボタン 前面コントロールパネル上にあります。このボ タンは、ラック内でのシステムの位置確認に使 用されます。 エンクロージャモードスイッチ システムの前面にあります。このスイッチは PowerVault MD3600i シリーズストレージア レイには適用されません。 パスワードリセットスイッチ RAID コントローラモジュールの背面パネルに あります。このスイッチはストレージアレイパ スワードのリセットに使用します。 電源 装置 AC 電源装置(各電源装置につき) ワット数 600 W
ハードディスクドライブで利用可能な電力(スロット 1 個あたり) PowerVault MD3600i 25 W PowerVault MD3620i 12 W RAID コントローラモジュール電力(スロット 1 個あたり) 最高電力消費量 100 W サイズと重量 PowerVault MD3600i 縦幅 8.68 cm 横幅 44.63 cm 奥行き 60.20 cm 重量(最大構成) 29.30 kg 重量(空の状態) 8.84 kg PowerVault MD3620i 縦幅 8.68 cm 横幅 44.63 cm 奥行き 54.90 cm 重量(最大構成) 24.2 kg 重量(空の状態) 8.61 kg 環境 メモ : 特定のシステム構成でのその他の環境条件の詳細については、 www.dell.
環境 (続き) 保管時 5 ~ 95 パーセント(結露しないこと) 最大振動 動作時 15 分間にわたり 3-200 Hz で 0.25 G 保管時 15 分間にわたり 3-200 Hz で 0.5 G 最大衝撃 動作時 z 軸の正方向に 2.6 ミリ秒で 31 G の 1 衝撃パ ルス(システムの各面に対して 1 パルス) 保管時 x、y、z 軸の正および負方向に 6 連続衝撃パル ス(システムの各面に対して 1 パルス)、2 ミ リ秒以下で 71 G 高度 動作時 -16 ~ 3,048 m メモ : 高度が 2950 フィートを超えると、動作 時の許容最大温度は、550 フィートごとに 1°F ずつ低下します。 保管時 -16 ~ 10,600 m 空気汚染物質レベル クラス G1(ISA-S71.
86 はじめに
Dell PowerVault MD3600i 및 MD3620i 스토리지 배열 시스템 시작 안내서 정규 모델 시리즈 E03J 및 E04J
주 , 주의 및 경고 주 : " 주 " 는 컴퓨터를 보다 효율적으로 사용하는 데 도움을 주는 중요 정보를 알려줍니다 . 주의 : " 주의 " 는 지침을 준수하지 않을 경우의 하드웨어 손상이나 데이터 손 실 위험을 설명합니다 . 경고 : " 경고 " 는 재산상의 피해나 심각한 부상 또는 사망을 유발할 수 있는 위험이 있음을 알려줍니다 . ____________________ 이 발행물에 수록된 정보는 사전 통보 없이 변경될 수 있습니다 . © 2011 Dell Inc. 저작권 본사 소유 . Dell Inc. 의 서면 승인 없이 어떠한 방식으로든 본 자료를 무단 복제하는 행위는 엄격히 금지 됩니다 . 본 텍스트에 사용된 상표 : Dell ™ , DELL 로고 , PowerVault ™는 Dell Inc. 의 상표입니다 . Microsoft® 및 Windows Server® 는 미국 및 / 또는 기타 국가에서 Microsoft Corporation 의 상표 또는 등록 상표입니다 .
시작하기 전에 주 : 본 설명서의 Dell PowerVault MD3600i 시리즈 스토리지 배열 은 Dell PowerVault MD3600i 및 Dell PowerVault MD3620i 를 의미합니다 . Dell PowerVault MD1200 시리즈 확장 인클로저는 Dell PowerVault MD1200 및 Dell PowerVault MD1220 을 나타냅니다 . Dell PowerVault MD3600i 시리즈 스토리지 배열을 설치하기에 앞서 특정 모범사례를 참조하여 스토리지 배열이 최대 효율 상태에서 작동하고 ( 필 요한 경우 ) 완전 중복성을 제공할 수 있도록 해야 합니다 . • PowerVault MD3600i 시리즈 스토리지 배열은 Category 6 이상의 케이 블 , 10GBase-T 사용가능 패치 패널 및 스위치로 구성된 10GBase-T 사용 가능 인프라를 필요로 하는 10GBase-T 제품입니다 .
• 호스트 서버와 스토리지 배열 간에 케이블을 연결하기 전에 , 각각의 포 트와 커넥터에 물리적으로 라벨을 부착하십시오 . • 네트워크에서 전원을 순환시킬 경우 반드시 올바른 전원 켜기 및 전원 끄기 절차를 따르십시오 . 또한 , 중요한 네트워크 구성요소들이 개별 전원 회로에 위치하고 있는지 확인해야 합니다 . 주 : 본 설명서에 제시된 그림들은 SAN 환경에서 오직 1 개의 PowerVault MD3600i 시리즈 스토리지 배열에 대한 케이블 연결을 나타냅니다 . 본 그림들은 PowerVault MD3600i 시리즈 스토리지 배열의 기본 IP 주소만을 나타냅니다 . SAN 환경에서 하나 이상의 PowerVault MD3600i 시리즈 스토리지 배열을 케이블 로 연결하려면 , Deployment Guide ( 배치 안내서 ) 를 참조하십시오 .
iSCSI 워크시트 완료 IPv4 설정 A 호스트 서버 192.168.131.101( 입력 1 기본값 ) 192.168.130.101( 입력 0 기본값 ) 상호 CHAP 암호 192.168.128.101( 관리 네트워크 포트 ) PowerVault MD3600i 시 리즈 스토리지 배열 B 대상 CHAP 암호 192.168.130.102( 입력 0 기본값 ) 192.168.131.102( 입력 1 기본값 ) 192.168.128.102( 관리 네트워크 포트 ) 둘 이상의 호스트 서버에 대해 추가 공간이 필요한 경우 추가 시트를 사용하십시오 . 주 : CHAP(Challenge Handshake Authentication Protocol) 는 스토리지 배열 ( 대상 ) 에서 호스 트 서버의 iSCSI 초기자를 인증하는 선택적인 iSCSI 인증 방법입니다 . 자세한 사항은 , 배치 안 내서의 “CHAP 인증 이해”를 참조하십시오 .
주 : IPv6 워크시트에 관한 정보는 , Deployment Guide( 배치 안내서 ) 를 참조하 십시오 . 기타 설명서 및 필요할 수 있는 매체 경고 : 시스템과 함께 제공되는 안전 및 규제 정보를 참조하십시오 . 보증 정 보는 이 문서에 포함되거나 별도의 문서로 제공될 수 있습니다 . 주 : PowerVault MD3600i 시리즈 스토리지 배열과 관련된 모든 문서는 support.dell.com/manuals 에서 이용할 수 있습니다 . • 랙 솔루션과 함께 제공되는 랙 설명서에는 시스템을 랙에 설치하는 방 법이 기술되어 있습니다 . • Owner's Manual(소유자 매뉴얼)에서는 시스템 기능에 대한 정보를 제공 하고 시스템 문제 해결 방법 및 시스템 구성부품 설치 또는 교체 방법을 설명합니다 . • Deployment Guide( 배치 안내서 ) 에서는 소프트웨어와 하드웨어의 설치 와 구성에 관한 정보를 제공합니다 .
호스트 서버 준비 지원되는 운영 체제 • Microsoft Windows Server • Red Hat Enterprise Linux • SUSE LINUX Enterprise Server • VMware 주 : 지원되는 모든 운영 체제 버전에 관한 최신 정보는 support.dell.com/manuals 에서 Support Matrix ( 지원 매트릭스 ) 를 참조하십 시오 . iSCSI 용 추가 NICs 추가적인 NICs 를 설치하는 경우 , 다음과 같이 권장됩니다 : • iSCSI 트래픽용 전용 중복 저장장치 네트워크를 사용합니다 . 전용 네트 워크를 사용할 수 없는 경우 , 가상 근거리 통신망 (VLAN) 을 사용하여 일반 네트워크 트래픽에서 iSCSI 트래픽을 분리합니다 . • iSCSI 트래픽 전용의 추가적인 NICs 를 사용합니다 . • NICs 는 중복성을 위해 쌍으로 추가되어야 합니다 . 주 : 또한 , 단일 NIC 도 지원됩니다 .
일반구성 SAN 연결 호스트의 케이블 연결 다음 그림에 나타난 바와 같이 서버 , 스위치 , 및 스토리지 배열 사이에 모 든 케이블을 연결하십시오 . 스토리지 배열 케이블 연결에 대한 자세한 내 용은 , support.dell.com/manuals 의 배치 안내서를 참조하십시오 .
직접 연결 호스트의 케이블 연결 서버 1 서버 2 스토리지 배열 회사 , 공용 또는 개인 네트워크 시스템 시작 안내서 95
설치 및 구성 경고 : 다음 절차를 수행하기 전에 시스템과 함께 제공되는 안전 지침을 검토 하십시오 . 시스템 포장 풀기 시스템의 포장을 풀고 시스템과 함께 제공된 포장 리스트와 각각의 항목을 비교하여 확인합니다 . 랙에 레일 및 시스템 설치 시스템과 함께 제공되는 안전 지침 및 랙 설치 지침에 따라 레일을 조립하 고 시스템을 랙에 설치합니다 . 주 : 무게 하중의 균형을 잡으려면 , 랙 하단에 PowerVault MD3600i 시리즈 스 토리지 배열을 설치하고 그 위에 PowerVault MD1200 시리즈 확장 인클로저를 설치하는 것이 좋습니다 .
전원 케이블 연결 전원 케이블을 연결하기 전에 전원 스위치가 꺼짐 (OFF) 위치에 있는지 확인하십시오 . 시스템의 전원 케이블을 시스템에 연결합니다 . 전원 케이블 고정 제공된 스트랩을 사용하여 케이블을 브래킷에 단단히 고정합니다 . 전원 케이블의 반대쪽 끝을 접지된 전원이나 UPS(Uninterrupted Power Supply) 또는 PDU(Power Distribution Unit) 와 같은 별도의 전원에 연결합 니다 . 각각의 전원 공급 장치는 개별 전원 회로에 연결해야 합니다 .
확장 인클로저의 케이블 연결 PowerVault MD1200 시리즈 확장 인클로 저 2 ( 선택사양 ) PowerVault MD1200 시리즈 확장 인클로 저 1 ( 선택사양 ) PowerVault MD3600i 시리즈 스토리지 배열 인클로저 켜기 다음의 순서대로 구성요소를 켜십시오 . 1 ( 사용하는 경우 ) 이더넷 스위치 2 ( 사용하는 경우 ) PowerVault MD1200 시리즈 확장 인클로저 주 : 스토리지 배열의 전원을 켜기 전에 , 인클로저 앞에 위치한 확장 인 클로저 상태 LED 가 청색인지 확인합니다 . 3 PowerVault MD3600i 시리즈 스토리지 배열 주 : 호스트 서버의 전원을 켜기 전에 , 스토리지 배열 앞에 위치한 스토 리지 배열 상태 LED 가 청색인지 확인합니다 .
4 호스트 서버 베젤 설치 베젤 ( 선택 사양 ) 을 설치합니다 .
MD 스토리지 소프트웨어 설치 주 : MD 스토리지 소프트웨어 설치 , 인클로저 설치 , 설치후 작업에 관한 자세 한 설명은 배치 안내서를 참조하십시오 . MD 스토리지 관리자 소프트웨어는 스토리지 배열을 구성 , 관리 , 모니터 합니다 . MD 구성 유틸리티 (MDCU) 는 관리 및 iSCSI 호스트 포트 구성 과 iSCSI 모듈형 디스크 스토리지 배열에 대한 세션 생성에 대한 통합 접근 법을 제공해주는 선택사양 유틸리티입니다 . 스토리지 배열에 연결된 각 각의 호스트 서버에 iSCSI 를 구성하려면 MDCU 를 사용하도록 권장합니 다 . MD 스토리지 소프트웨어를 설치하려면 : 1 MD 시리즈 자원 매체를 삽입합니다 . 운영 체제에 따라 , 설치 프로그램이 자동으로 시작될 수 있습니다 . 설치 프로그램이 자동으로 시작되지 않으면 , 설치 매체 ( 또는 다 운로드된 설치 프로그램 이미지 ) 의 루트 디렉터리를 탐색하고 md_launcher.exe 파일을 실행합니다 .
6 호스트 서버가 재부팅되면 이벤트 모니터 서비스를 자동으로 시작할 것인지 또는 수동으로 시작할 것인지 여부를 선택합니다 . 주 : 이 옵션은 Windows 클라이언트 소프트웨어 설치에만 적용 가능합 니다 . 7 설치 위치를 확인하고 Install( 설치 ) 를 클릭합니다 . 8 프롬프트시 , 설치가 완료되면 호스트 서버를 재부팅합니다 . 9 재부팅이 완료되면 , MDCU 는 자동으로 시작될 수 있습니다 . MDCU 가 자동으로 시작되지 않으면 , 수동으로 시작하십시오 . • Windows 기반 운영 체제의 경우 , 시작→ Dell → 모듈러 디스크 구 성 유틸리티를 클릭합니다 . • Linux 기반 운영 체제의 경우 , 바탕화면의 모듈러 디스크 구성 유틸 리티 아이콘을 더블 클릭합니다 . 주 : MDCU 가 설치 않된 경우 , support.dell.com/manuals 에서 Deployment Guide ( 배치 안내서 ) 를 참조하십시오 .
서비스 태그 찾기 사용자의 시스템은 고유한 특급 서비스 코드 및 서비스 태그 번호로 식별 됩니다 . 특급 서비스 코드와 서비스 태그는 시스템 전면과 RAID 컨트롤러 모듈 옆의 시스템 후면에서 확인할 수 있습니다 . 이 정보는 Dell 에서 적절 한 직원과 지원 통화를 구성할 경우 사용됩니다 . NOM 정보 ( 멕시코에만 해당 ) 다음 정보는 멕시코 표준 규격 (NOM) 의 요구 사항을 준수하는 본 문서에 기술된 장치에 대한 내용입니다 . 수입업체 : 모델 번호 : 공급 전압 : 주파수 : 전류 소모량 : 102 E03J 및 E04J 100 ~ 240V CA 50/60Hz 8.
기술 사양 드라이브 PowerVault MD3600i 3.5 인치 SAS 핫스왑이 가능한 하드 드라이 브 최대 12 개 (3.0 Gbps 및 6.0 Gbps) PowerVault MD3620i 2.5 인치 SAS 핫스왑이 가능한 하드 드라이 브 최대 24 개 (3.0 Gbps 및 6.
확장 PowerVault MD1200 시리즈 PowerVault MD1200 또는PowerVault MD1220 확장 인클로저의 조합에 의해 최대 192 개의 하드 드라이브를 지원합니다 192 개의 하드 드라이브에 대한 지원은 고급 기능으로 활성 화가 필요합니다 . 고급 기능을 사용하지 않 고 지원되는 최대 하드 드라이브 수는 120 입 니다 . 중복 경로 연결성은 각각의 하드 드라이브 에 대한 중복 데이터 경로를 제공합니다 .
LED 표시등 ( 계속 ) RAID 컨트롤러 모듈 8 개의 단일 컬러 LEDs: • 전지 결함 표시용 1 개 • 캐시 활성화 표시용 1 개 • 컨트롤러 결함 표시용 1 개 • 컨트롤러 전원 표시용 1 개 • 시스템 확인용 1 개 • 관리 이더넷 작동 표시용 1 개 • 2 개의 iSCSI IN 포트 작동 4 개의 2 색 LEDs: • 2 개의 iSCSI IN 링크 속도 • SAS 출력 링크 또는 결함 표시용 1 개 • 관리 이더넷 링크 속도 표시용 1 개 스위치 시스템 확인 단추 전면 제어판에 있음 . 이 단추는 랙에서 시스 템의 위치를 확인하는데 사용됩니다 . 인클로저 모드 스위치 시스템의 전면에 위치함 . 본 스위치는 PowerVault MD3600i 시리즈 스토리지 배열 에 적용할 수 없습니다 . 암호 재설정 스위치 RAID 컨트롤러 모듈의 후면 패널에 위치 함 . 이 스위치는 스토리지 배열 암호 재설 정에 사용됩니다 .
사용 가능한 하드 드라이브 전원 ( 슬롯당 ) PowerVault MD3600i 25 W PowerVault MD3620i 12 W RAID 컨트롤러 모듈 전원 ( 슬롯당 ) 최대 소비 전력 100 W 실제 PowerVault MD3600i 높이 8.68 cm (3.41 인치 ) 너비 44.63cm (17.57 인치 ) 깊이 60.20 cm (23.70 인치 ) 무게 ( 최대 구성 시 ) 29.30 kg (64.6 lb) 무게 ( 비어 있을 경우 ) 8.84 kg (19.5 lb) PowerVault MD3620i 높이 8.68 cm (3.41 인치 ) 너비 44.63cm (17.57 인치 ) 깊이 54.90 cm (21.61 인치 ) 무게 ( 최대 구성 시 ) 24.2 kg (53.4 lb) 무게 ( 비어 있을 경우 ) 8.61 kg (19lb) 환경적 특성 주 : 특정 시스템 구성을 위한 환경 측정에 대한 자세한 내용은 www.dell.
환경적 특성 ( 계속 ) 상대 습도 작동 20% ~ 80%( 비응축 ), 시간당 최고 10% 의 습도 변화 기준 보관 5 ~ 95%( 비응축 ) 최대 진동 작동 3 ~ 200Hz 에서 15 분간 0.25G 보관 3 ~ 200Hz 에서 15 분간 0.5G 최대 충격 작동 작동 방향으로 2.6ms 동안 (+) z 축으로 31G 의 충격 펄스 1 회 ( 시스템 각 면에 1 회의 펄스 ) 보관 최대 2ms 동안 (+/-) x, y, z 축으로 71G 의 연 속 충격 펄스 6 회 ( 시스템 각 면에 1 회의 펄스 ) 고도 작동 –16 ~ 3,048m(–50 ~ 10,000ft) 주 : 2,950 피트 이상의 고도에서 최대 작동 온도는 1°F/550ft 로 감소됩니다 . 보관 –16 ~ 10,600m(–50 ~ 35,000ft) 공기 중 오염 물질 수준 등급 ISA-S71.
108 시스템 시작 안내서
Printed in China. Dicetak di China. Printed on Recycled Paper. w w w. d e l l . c o m | s u p p o r t . d e l l .
Printed in Malaysia. Dicetak di Malaysia. w w w. d e l l . c o m | s u p p o r t . d e l l .