Owners Manual
Table Of Contents
- Dell PowerVault MD3260/3260i/3660i/3660f/3060e Storage Arrays Owner's Manual
- About Your System
- Controller Modules
- RAID Controller Modules
- MD3260 SAS RAID Controller Module Features And Indicators
- MD3260i iSCSI RAID Controller Module Features And Indicators
- MD3660i iSCSI RAID Controller Module Features And Indicators
- MD3660f Fibre Channel RAID Controller Module Features And Indicators
- Expansion Controller Modules
- Controller Module—Additional Features
- Storage Array Thermal Shutdown
- System Password Reset
- Installing System Components
- Troubleshooting Your System
- Safety First—For You And Your System
- Troubleshooting Storage Array Startup Failure
- Troubleshooting Loss Of Communication
- Troubleshooting An SFP Transceiver
- Troubleshooting External Connections
- Troubleshooting Power Supply Modules
- Troubleshooting Array Cooling Problems
- Troubleshooting Expansion Enclosure Management Modules
- Troubleshooting RAID Controller Modules
- Troubleshooting Physical Disks
- Troubleshooting Array And Expansion Enclosure Connections
- Troubleshooting A Wet Storage Array
- Troubleshooting A Damaged Array
- Controller Failure Conditions
- Technical Specifications
- Getting Help

Removing A Physical Disk From A Physical-Disk Drawer
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Remove the front bezel.
2. Identify the physical-disk drawer in which the faulty physical disk is installed.
3. Open the physical-disk drawer.
4. Identify and locate the faulty physical disk in the physical-disk drawer.
CAUTION: Remove the physical disk from the system only if the service action allowed indicator lights blue.
Removing the physical disk from the system when the service action allowed indicator is off may damage the
system.
NOTE: The service action required indicator lights blue on the:
– RAID controller module
– physical-disk drawer
– physical disk
5. Press the release tab to disengage the physical-disk carrier handle.
6. Rotate the physical-disk carrier handle upward to disengage the physical disk from its connector.
7. Hold the physical-disk carrier handle and lift the physical disk out and away from the system.
Figure 22. Removing and Installing the Physical Disk in the Physical-Disk Drawer
1.
physical disk
2. physical-disk carrier handle
3. physical-disk connector
4. notches (2)
31