Owners Manual
Table Of Contents
- Dell PowerVault MD3260/3260i/3660i/3660f/3060e Storage Arrays Owner's Manual
- About Your System
- Controller Modules
- RAID Controller Modules
- MD3260 SAS RAID Controller Module Features And Indicators
- MD3260i iSCSI RAID Controller Module Features And Indicators
- MD3660i iSCSI RAID Controller Module Features And Indicators
- MD3660f Fibre Channel RAID Controller Module Features And Indicators
- Expansion Controller Modules
- Controller Module—Additional Features
- Storage Array Thermal Shutdown
- System Password Reset
- Installing System Components
- Troubleshooting Your System
- Safety First—For You And Your System
- Troubleshooting Storage Array Startup Failure
- Troubleshooting Loss Of Communication
- Troubleshooting An SFP Transceiver
- Troubleshooting External Connections
- Troubleshooting Power Supply Modules
- Troubleshooting Array Cooling Problems
- Troubleshooting Expansion Enclosure Management Modules
- Troubleshooting RAID Controller Modules
- Troubleshooting Physical Disks
- Troubleshooting Array And Expansion Enclosure Connections
- Troubleshooting A Wet Storage Array
- Troubleshooting A Damaged Array
- Controller Failure Conditions
- Technical Specifications
- Getting Help

4
Troubleshooting Your System
Safety First—For You And Your System
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
Troubleshooting Storage Array Startup Failure
If your system halts during startup, check if:
• The array emits a series of beeps.
• The array fault LEDs are lit.
• There is a constant scraping or grinding sound when you access the physical disk.
For assistance, contact Dell Support.
Troubleshooting Loss Of Communication
For information about troubleshooting loss of communication, see Troubleshooting Array And Expansion Enclosure
Connections.
Troubleshooting An SFP Transceiver
NOTE: This section is applicable only for the Dell PowerVault MD3660f storage enclosures.
WARNING: Data processing environments can contain equipment transmitting on system links with Laser modules
that operate at greater than Class 1 power levels. Never look into the end of an optical fibre cable or open
receptacle.
CAUTION: When handling static-sensitive devices, take precautions to avoid damaging the product from static
electricity.
NOTE: Before proceeding with this section, see Working With SFP Modules And Fibre Optic Cables in the
Dell
PowerVault MD3660f Series Storage Arrays Deployment Guide
at support.dell.com/manuals.
NOTE: Equip yourself with antistatic protection and a replacement small form-factor pluggable (SFP) transceiver
before replacing an SFP transceiver in the RAID controller module. Also, see the initial setup information for the
enclosure to verify LED definitions.
CAUTION: To prevent degraded performance, do not twist, fold, pinch, or step on fibre optic cables. Do not bend
the fibre optic cables tighter than a 5 cm (2 inch) radius.
45