Owners Manual

Physical-Drive Indicator Patterns
Figure 5. Physical-Drive Indicators
1. physical-drive activity indicator (green)
2. physical-drive status indicator (green and amber)
NOTE: If the physical drive is in Advanced Host Controller Interface (AHCI) mode, the status indicator (on the right
side) does not function and remains off.
Table 2. Physical-Drive Indicators
Drive-Status Indicator Pattern
(RAID Only)
Condition
Blinks green two times per second Identifying drive or preparing for removal
Off Drive ready for insertion or removal
NOTE: The drive status indicator remains off until all physical drives are
initialized after the system is turned on. Drives are not ready for insertion or
removal during this time.
Blinks green, amber, and turns off Predicted drive failure
Blinks amber four times per second Drive failed
Blinks green slowly Drive rebuilding
Steady green Drive online
Blinks green three seconds, amber three
seconds, and turns off six seconds
Rebuild aborted
Power Supply and Cooling Fan Features
The MD3800f and MD3820f Series storage array includes two integrated, hot-swappable power supply/cooling fan modules. Both
modules must be installed to ensure proper cooling. The system requires at least one of the cooling fans to function, to avoid overheating.
A power supply/cooling fan module can be replaced without powering down the system. For information on removing and installing the
modules, see Power Supply/Cooling Fan Module.