User Manual
Table Of Contents
- Dell PowerVault MD 34XX/38XX Series Storage Arrays Administrator's Guide
- Introduction
- About Your MD Series Storage Array
- Physical Disks, Virtual Disks, And Disk Groups
- Disk Pools
- Thin Virtual Disks
- RAID Levels
- Segment Size
- Virtual Disk Operations
- Disk Group Operations
- RAID Background Operations Priority
- Virtual Disk Migration And Disk Roaming
- Advanced Features
- Multi-Path Software
- Load Balancing
- Monitoring System Performance
- Interpreting Performance Monitor Data
- Viewing Real-time Graphical Performance Monitor Data
- Customizing the Performance Monitor Dashboard
- Specifying Performance Metrics
- Viewing Real-time Textual Performance Monitor
- Saving Real-time Textual Performance Data
- Starting and Stopping Background Performance Monitor
- Viewing Information about the Current Background Performance Monitor Session
- Viewing Current Background Performance Monitor Data
- Saving the Current Background Performance Monitor Data
- Viewing Saved Background Performance Monitor Data
- What are invalid objects in the Performance Monitor?
- Discovering And Managing Your Storage Array
- Out-Of-Band Management
- In-Band Management
- Storage Arrays
- Setting Up Your Storage Array
- Locating Storage Arrays
- Naming Or Renaming Storage Arrays
- Setting A Password
- Adding Or Editing A Comment To An Existing Storage Array
- Removing Storage Arrays
- Enabling Premium Features
- Displaying Failover Alert
- Changing The Cache Settings On The Storage Array
- Changing Expansion Enclosure ID Numbers
- Changing The Enclosure Order
- Configuring Alert Notifications
- Battery Settings
- Setting The Storage Array RAID Controller Module Clocks
- Using iSCSI
- Changing The iSCSI Target Authentication
- Entering Mutual Authentication Permissions
- Creating CHAP Secrets
- Changing The iSCSI Target Identification
- Changing The iSCSI Target Discovery Settings
- Configuring The iSCSI Host Ports
- Advanced iSCSI Host Port Settings
- Viewing Or Ending An iSCSI Session
- Viewing iSCSI Statistics And Setting Baseline Statistics
- Edit, Remove, Or Rename Host Topology
- Event Monitor
- About Your Host
- Disk Groups, Standard Virtual Disks, And Thin Virtual Disks
- Creating Disk Groups And Virtual Disks
- Thin Virtual Disks
- Advantages Of Thin Virtual Disks
- Physical Vs Virtual Capacity On A Thin Virtual Disk
- Thin Virtual Disk Requirements And Limitations
- Thin Volume Attributes
- Thin Virtual Disk States
- Comparison—Types Of Virtual Disks And Copy Services
- Rollback On Thin Virtual Disks
- Initializing A Thin Virtual Disk
- Changing A Thin Virtual Disk To A Standard Virtual Disk
- Choosing An Appropriate Physical Disk Type
- Physical Disk Security With Self Encrypting Disk
- Configuring Hot Spare Physical Disks
- Enclosure Loss Protection
- Drawer Loss Protection
- Host-To-Virtual Disk Mapping
- Creating Host-To-Virtual Disk Mappings
- Modifying And Removing Host-To-Virtual Disk Mapping
- Changing Controller Ownership Of The Virtual Disk
- Removing Host-To-Virtual Disk Mapping
- Changing The RAID Controller Module Ownership Of A Disk Group
- Changing The RAID Level Of A Disk Group
- Removing A Host-To-Virtual Disk Mapping Using Linux DMMP
- Restricted Mappings
- Storage Partitioning
- Disk Group And Virtual Disk Expansion
- Disk Group Migration
- Storage Array Media Scan
- Disk Pools And Disk Pool Virtual Disks
- Difference Between Disk Groups And Disk Pools
- Disk Pool Restrictions
- Creating A Disk Pool Manually
- Automatically Managing The Unconfigured Capacity In Disk Pools
- Locating Physical Disks In A Disk Pool
- Renaming A Disk Pool
- Configuring Alert Notifications For A Disk Pool
- Adding Unassigned Physical Disks To A Disk Pool
- Configuring The Preservation Capacity Of A Disk Pool
- Changing The Modification Priority Of A Disk Pool
- Changing The RAID Controller Module Ownership Of A Disk Pool
- Checking Data Consistency
- Deleting A Disk Pool
- Viewing Storage Array Logical Components And Associated Physical Components
- Secure Disk Pools
- Changing Capacity On Existing Thin Virtual Disks
- Creating A Thin Virtual Disk From A Disk Pool
- Using SSD Cache
- How SSD Cache Works
- Benefits Of SSD Cache
- Choosing SSD Cache Parameters
- SSD Cache Restrictions
- Creating An SSD Cache
- Viewing Physical Components Associated With An SSD Cache
- Locating Physical Disks In An SSD Cache
- Adding Physical Disks To An SSD Cache
- Removing Physical Disks From An SSD Cache
- Suspending Or Resuming SSD Caching
- Changing I/O Type In An SSD Cache
- Renaming An SSD Cache
- Deleting An SSD Cache
- Using The Performance Modeling Tool
- Premium Feature—Snapshot Virtual Disk
- Snapshot Virtual Disk Vs. Snapshot Virtual Disk (Legacy)
- Snapshot Images And Groups
- Snapshot Virtual Disk Read/Write Properties
- Snapshot Groups And Consistency Groups
- Understanding Snapshot Repositories
- Creating Snapshot Images
- Scheduling Snapshot Images
- Performing Snapshot Rollbacks
- Creating A Snapshot Group
- Converting A Snapshot Virtual Disk To Read-Write
- Viewing Associated Physical Components Of An Individual Repository Virtual Disk
- Creating A Consistency Group
- Creating A Snapshot Virtual Disk Of A Snapshot Image
- Snapshot Virtual Disk Limitations
- Creating A Snapshot Virtual Disk
- Creating A Snapshot Virtual Disk Repository
- Changing The Settings Of A Snapshot Virtual Disk
- Disabling A Snapshot Virtual Disk Or Consistency Group Snapshot Virtual Disk
- Re-creating A Snapshot Virtual Disk Or Consistency Group Snapshot Virtual Disk
- Renaming A Snapshot Virtual Disk Or Consistency Group Snapshot Virtual Disk
- Deleting A Snapshot Virtual Disk Or Consistency Group Snapshot Virtual Disk
- Creating A Consistency Group Snapshot Virtual Disk
- Creating A Consistency Group Snapshot Virtual Disk Repository (Manually)
- Disabling A Snapshot Virtual Disk Or Consistency Group Snapshot Virtual Disk
- Re-creating A Snapshot Virtual Disk Or Consistency Group Snapshot Virtual Disk
- Changing The Modification Priority Of An Overall Repository Virtual Disk
- Changing The Media Scan Setting Of An Overall Repository Virtual Disk
- Changing The Pre-read Consistency Check Setting Of An Overall Repository Virtual Disk
- Increasing The Capacity Of An Overall Repository
- Decreasing The Capacity Of The Overall Repository
- Performing A Revive Operation
- Premium Feature—Snapshot Virtual Disks (Legacy)
- Scheduling A Snapshot Virtual Disk
- Creating A Snapshot Virtual Disk Using The Simple Path
- Creating A Snapshot Virtual Disk Using The Advanced Path
- Specifying Snapshot Virtual Disk Names
- Snapshot Repository Capacity
- Re-Creating Snapshot Virtual Disks
- Disabling A Snapshot Virtual Disk
- Re-Creating A Snapshot Virtual Disk
- Premium Feature—Virtual Disk Copy
- Using Virtual Disk Copy With Snapshot Or Snapshot (Legacy) Premium Feature
- Types Of Virtual Disk Copies
- Creating A Virtual Disk Copy For An MSCS Shared Disk
- Virtual Disk Read/Write Permissions
- Virtual Disk Copy Restrictions
- Creating A Virtual Disk Copy
- Preferred RAID Controller Module Ownership
- Failed RAID Controller Module
- Copy Manager
- Copying The Virtual Disk
- Storage Array Performance During Virtual Disk Copy
- Setting Copy Priority
- Stopping A Virtual Disk Copy
- Recopying A Virtual Disk
- Removing Copy Pairs
- Device Mapper Multipath For Linux
- Configuring Asymmetric Logical Unit Access
- Premium Feature—Remote Replication
- About Asynchronous Remote Replication
- Remote Replicated Pairs And Replication Repositories
- Types Of Remote Replication
- Remote Replication Requirements And Restrictions
- Setting Up Remote Replication
- Activating Remote Replication Premium Features
- Deactivating Remote Replication
- Remote Replication Groups
- Replicated Pairs
- Management Firmware Downloads
- Downloading RAID Controller And NVSRAM Packages
- Downloading Both RAID Controller And NVSRAM Firmware
- Downloading Only NVSRAM Firmware
- Downloading Physical Disk Firmware
- Downloading MD3060e Series Expansion Module EMM Firmware
- Self-Monitoring Analysis And Reporting Technology (SMART)
- Media Errors And Unreadable Sectors
- Firmware Inventory
- System Interfaces
- Storage Array Software
- Start-Up Routine
- Device Health Conditions
- Trace Buffers
- Collecting Physical Disk Data
- Event Log
- Recovery Guru
- Storage Array Profile
- Viewing The Physical Associations
- Recovering From An Unresponsive Storage Array Condition
- Locating A Physical Disk
- Locating An Expansion Enclosure
- Capturing The State Information
- SMrepassist Utility
- Unidentified Devices
- Recovering From An Unidentified Storage Array
- Starting Or Restarting The Host Context Agent Software
- Getting Help

Multi-Path Software
Multi-path software (also referred to as the failover driver) is the software resident on the host server that
provides management of the redundant data path between the host server and the storage array. For the
multi-path software to correctly manage a redundant path, the configuration must have redundant iSCSI
connections and cabling.
The multi-path software identifies the existence of multiple paths to a virtual disk and establishes a
preferred path to that disk. If any component in the preferred path fails, the multi-path software
automatically re-routes I/O requests to the alternate path so that the storage array continues to operate
without interruption.
NOTE: Multi-path software is available on the MD Series storage arrays resource DVD.
Preferred And Alternate Controllers And Paths
A preferred controller is a RAID controller module designated as the owner of a virtual disk or disk group.
The preferred controller is automatically selected by the MD Storage Manager when a virtual disk is
created. You can change the preferred RAID controller module owner of a virtual disk after it is created. If
a host is connected to only one RAID controller module, the preferred owner must manually be assigned
to the RAID controller module that the host can access.
Ownership of a virtual disk is moved from the preferred controller to the secondary controller (also called
the alternate controller) when the preferred controller is:
• Physically removed
• Updating firmware
• Involved in an event that caused failover to the alternate controller
Paths used by the preferred RAID controller module to access either the disks or the host server are
called the preferred paths; redundant paths are called the alternate paths. If a failure causes the preferred
path to become inaccessible, the storage array automatically uses the alternate path to access data, and
the enclosure status LED blinks amber.
Virtual Disk Ownership
The MD Storage Manager can be used to automatically build and view virtual disks. It uses optimal
settings to stripe the disk group. Virtual disks are assigned to alternating RAID controller modules when
they are created. This default assignation provides a simple means for load balancing the workload of the
RAID controller modules.
Ownership can later be modified to balance workload according to actual usage. If virtual disk ownership
is not manually balanced, it is possible for one controller to have the majority of the work, while the other
controller is idle. Limit the number of virtual disks in a disk group. If multiple virtual disks are in a disk
group, consider:
• The impact each virtual disk has on other virtual disks in the same disk group.
• The patterns of usage for each virtual disk.
• Different virtual disks have higher usage at different times of day.
33