Users Guide
Table Of Contents
- Contents
- Notes, Cautions, and Warnings
- _
- Installation Issues
- RAID 5 Configuration Defaults To RAID 1 After A Hard Drive Replacement
- RAID Configuration Does Not Match Factory Configuration After Reinstalling The Operating System
- The iSCSI Target Icon Is Missing In The Server Manager
- Error: -5000 Shows Unexpected System Error Message
- Error: -5001 Shows Invalid System Error Message
- Error: -5002 Shows Unsupported Hardware Configuration Error
- Error: -5003 Occurred While Creating An Operating System Volume
- Error: -5004 Occurred While Creating An Operating System Volume
- Error: -5005 Occured While Creating An Operating System Volume
- Error: -5006 Occurred While Creating An Operating System Volume
- Error: -5007 Occurred While Creating An Operating System Volume
- Third-party Tools And Utilities Error
- Package Provided Is Not A NAS Appliance Software
- Cannot Install PowerVault NAS Appliance Software On The NAS System
- Reinstallation Error Message Stays On The LCD
- Display Log Console Displays A Wrong Date
- Deployment Issues
- Management Issues
- Desktop Displays Incorrect System Information
- Insufficient Disk Space On A Volume Dedicated For iSCSI Virtual Disk
- Single Instance Storage (SIS) And File Server Resource Manager (FSRM) Display Incorrect Disk Space
- Cannot Install SIS On A Volume Without A Mount Point
- Groveler Service May Not Recognize A Volume After Changing The Drive Letter
- Turning Off The Firewall
- Update Issues
4. Reboot the Dell PowerVault Network Attached Storage (NAS) using the operating system
reinstallation media.
The iSCSI Target Icon Is Missing In The Server Manager
Description After installing the iSCSI Target software, the iSCSI Target icon is not present in the Server
Manager.
This issue occurs because the system is not properly refreshed.
Workaround/
Solution
To workaround this issue, perform one of the following steps:
• Refresh the Server Manager.
• Close and restart the Server Manager.
• Launch the Microsoft iSCSI Target Management tool. Click Start → Administrative Tools
→ Microsoft iSCSI Target.
Error: -5000 Shows Unexpected System Error Message
Description A required system resource cannot be located or is faulty.
Workaround/Solution This issue occurs because either the operating system reinstallation media, optical drive, or the
system is in an invalid state.
This is a known issue.
Error: -5001 Shows Invalid System Error Message
Description System restore is being performed on an unsupported system. This issue occurs because the
operation is not supported on the system.
Workaround/Solution To resolve this issue, remove the operating system reinstallation media immediately.
Error: -5002 Shows Unsupported Hardware Configuration Error
Description The system is unable to locate a supported RAID controller.
Workaround/
Solution
To workaround this issue, perform one of the following steps:
• Ensure that the disk controller card is connected to the internal drives and is properly seated
in the correct slot. For more information about connecting the card, see the
Hardware
Owner’s Manual
at support.dell.com/manuals.
• Enter the PERC BIOS during the operating system boot operation and ensure that the internal
drive controller is functional. For more information, see the PERC documentation at
support.dell.com/manuals.
• Ensure that your system supports an internal drive controller. For information about the
internal drive controllers supported on your system, see the system hardware
documentation at support.dell.com/manuals.
6