Users Guide
Table Of Contents
- Contents
- Notes, Cautions, and Warnings
- _
- Installation Issues
- RAID 5 Configuration Defaults To RAID 1 After A Hard Drive Replacement
- RAID Configuration Does Not Match Factory Configuration After Reinstalling The Operating System
- The iSCSI Target Icon Is Missing In The Server Manager
- Error: -5000 Shows Unexpected System Error Message
- Error: -5001 Shows Invalid System Error Message
- Error: -5002 Shows Unsupported Hardware Configuration Error
- Error: -5003 Occurred While Creating An Operating System Volume
- Error: -5004 Occurred While Creating An Operating System Volume
- Error: -5005 Occured While Creating An Operating System Volume
- Error: -5006 Occurred While Creating An Operating System Volume
- Error: -5007 Occurred While Creating An Operating System Volume
- Third-party Tools And Utilities Error
- Package Provided Is Not A NAS Appliance Software
- Cannot Install PowerVault NAS Appliance Software On The NAS System
- Reinstallation Error Message Stays On The LCD
- Display Log Console Displays A Wrong Date
- Deployment Issues
- Management Issues
- Desktop Displays Incorrect System Information
- Insufficient Disk Space On A Volume Dedicated For iSCSI Virtual Disk
- Single Instance Storage (SIS) And File Server Resource Manager (FSRM) Display Incorrect Disk Space
- Cannot Install SIS On A Volume Without A Mount Point
- Groveler Service May Not Recognize A Volume After Changing The Drive Letter
- Turning Off The Firewall
- Update Issues
Error: -5003 Occurred While Creating An Operating System Volume
Description Invalid operating system drive configuration. The layout of physical disks to be used as operating
system disks do not meet the required layout for the device.
Workaround/
Solution
To workaround this issue, perform one of the following steps:
• Ensure that all drives in the operating system drive slots are correctly attached and do not
have data on them. Physical disks for the operating system must be of the same type and
must be greater than 120 GB.
• Enter the PERC BIOS during the operating system boot operation and ensure that there are
no foreign configurations, drives are clean of all data, the drives meet the minimum size
requirement, and are fully functioning and accessible. For more information, see the PERC
documentation at support.dell.com/manuals.
Error: -5004 Occurred While Creating An Operating System Volume
Description Drives in the slots dedicated for operating system drives are empty.
Workaround/
Solution
To workaround this issue, perform one of the following steps:
• Ensure that all drives in the operating system drive slots are correctly attached and do not
have data on them. Physical disks for the operating system must be of the same type and
must meet the minimum size requirements.
• Enter the PERC BIOS during the operating system boot operation and ensure that there are
no foreign configurations, drives are clean of all data, the drives meet the minimum size
requirement, and are fully functioning and accessible. For more information, see the PERC
documentation at support.dell.com/manuals.
Error: -5005 Occured While Creating An Operating System Volume
Description Drives in expected operating system slots have existing foreign configurations.
Workaround/Solution To workaround this issue:
Enter the PERC BIOS during the operating system boot operation and ensure that:
• there are no foreign configurations
• drives are clean of all data
• the drives meet the minimum size requirement, and are fully functioning and accessible.
For more information, see the PERC documentation at support.dell.com/manuals.
Error: -5006 Occurred While Creating An Operating System Volume
Description
Unable to locate the PowerVault operating system reinstallation media.
Workaround/
Solution
To workaround this issue, perform one of the following steps:
7