Deployment Guide

21. Click Next.
The iSCSI Target Discovery screen is displayed.
22. In iSCSI Discovery Address for MD Array, enter one of the iSCSI port IP addresses of the PowerVault MD array for the iSCSI
target.
NOTE: The NX3610 supports two MD storage arrays. In version 01.01.02.016 of the NAS IDU, if a second array is not
attached to the NX3610 cluster, enter the IP address of the single storage array twice.
23. Click Next.
NOTE: It is highly recommended to copy the configuration details from the Configuration Summary screen and paste
it in a different file (.doc or .txt) for future reference.
The Configuration Summary screen displays all the configuration details for the selected NAS appliance.
24. Click Next.
The NAS IDU applies the cluster configuration to the selected NAS appliance. After the configuration is complete, the Configuration
Results screen is displayed. The NAS controller IQNs are displayed in the Configuration Results screen.
NOTE: It is highly recommended to copy the NAS controller IQN details from the Configuration Results screen and
paste it in a different file (.doc or .txt) for future reference. You must match these NAS controller IQNs in the
MDSM.
25. Set up your MD storage array using MDSM.
For more information, see Setting Up Your MD Storage Solution.
26. Click Finish.
16 Running NAS IDU