Users Guide
Table Of Contents
- Contents
- Notes, Cautions, and Warnings
- Installation Issues
- RAID 5 Configuration Defaults To RAID 1 After A Hard Drive Replacement
- RAID Configuration Does Not Match Factory Configuration After Reinstalling The Operating System
- The iSCSI Target Icon Is Missing In The Server Manager
- Error: -5000 Shows Unexpected System Error Message
- Error: -5001 Shows Invalid System Error Message
- Error: -5002 Shows Unsupported Hardware Configuration Error
- Error: -5003 Occurred While Creating An Operating System Volume
- Error: -5004 Occurred While Creating An Operating System Volume
- Error: -5005 Occured While Creating An Operating System Volume
- Error: -5006 Occurred While Creating An Operating System Volume
- Error: -5007 Occurred While Creating An Operating System Volume
- Third-party Tools And Utilities Error
- Package Provided Is Not A NAS Appliance Software
- Cannot Install PowerVault NAS Appliance Software On The NAS System
- Reinstallation Error Message Stays On The LCD
- Display Log Console Displays A Wrong Date
- Deployment Issues
- Management Issues
- Desktop Displays Incorrect System Information
- Insufficient Disk Space On A Volume Dedicated For iSCSI Virtual Disk
- Single Instance Storage (SIS) And File Server Resource Manager (FSRM) Display Incorrect Disk Space
- Cannot Install SIS On A Volume Without A Mount Point
- Groveler Service May Not Recognize A Volume After Changing The Drive Letter
- Turning Off The Firewall
- Update Issues

Cannot Install SIS On A Volume Without A Mount Point
Description If you install SIS on a volume without a mount point, such as a drive letter or folder mount point, the
operation fails while incorrectly displaying a message similar to the following:
SIS has been initialized on volume '\\?\Volume{f2eb8ac
f-0ad7-49b3-bd92- b93ce5680c85}\'. Restarting the Groveler
service...
Workaround/
Solution
To workaround this issue, assign a valid mount point to the volume before enabling SIS for the
volume.
Groveler Service May Not Recognize A Volume After Changing The
Drive Letter
Description SIS requires that all volumes using SIS must be assigned either a drive letter or a folder mount
point. If you use disk management to change the mount point or drive letter of a SIS volume, the
Groveler service may fail to recognize the new configuration immediately. The Groveler service
adapts to the change within an hour and restores full functionality.
Workaround/
Solution
To correct the issue, type sisadmin.exe /I at the command prompt.
Turning Off The Firewall
Description To turn off the firewall follow the steps given below.
Workaround/Solution
1. Launch Server Manager and navigate to the Configuration snap-in.
2. Expand the snap-in and right-click Windows Firewall with Advance Security.
3. Select Properties and turn off the required firewall.
14