Users Guide

1 Ready/Activity LED 3 Attention LED
2 Cleaning LED 4 Error LED
Table 20. Front Panel LED indicators
Library
Condition
Ready/Activity
LED
Cleaning LED Attention LED Error LED
Message on
Display
POST (Power ON
Self Test)
Flashes 2 times
every 3 seconds
OFF OFF OFF INITIALIZING...
INVENTORY...
Magazine open Flashes 2 times
every 3 seconds
OFF OFF OFF PLEASE INSERT
MAGAZINE
Magazine
unlocked
Flashes 2 times
every 3 seconds
OFF OFF OFF MAGAZINE
UNLOCKED
I/O Station open Flashes 2 times
every 3 seconds
OFF OFF OFF PLEASE CLOSE
I/O STATION
I/O Station
unlocked
Flashes 2 times
every 3 seconds
OFF OFF OFF N/A
Library rmware
is being updated
Flashes 2 times
every 3 seconds
OFF OFF OFF LOADER
FIRMWARE
UPDATING!
Drive rmware is
being updated
Flashes 2 times
every 3 seconds
OFF OFF OFF DRIVE
FIRMWARE
UPDATING!
Drive dump is
being uploaded
to host computer
Flashes 2 times
every 3 seconds
OFF OFF OFF DRIVE DUMP
DATA
UPLOADING!
Library is offline Flashes 2 times
every 3 seconds
OFF OFF OFF OFFLINE
Cartridge is
being moved
Flashes 2 times
every 3 seconds
OFF OFF OFF READY
Library error
occurred
ON OFF OFF ON *** CHK ***
CODE: [XXXX]
Drive error
occurred
ON OFF OFF ON DRIVE FAULT
CODE: [X]
Cartridge error
occurred
ON OFF ON OFF MEDIA FAULT
CODE: [X]
Cleaning
cartridge expired
ON OFF ON OFF REPLACE
CLEANING
MEDIA
Drive requested
cleaning
ON ON OFF OFF CLEAN DRIVE
Drive is being
cleaned
ON Flashes 1 time
per second
OFF OFF CLEANING...