Users Guide
Table 21. Library error codes (continued)
Code (H) Description
Panel
Indication
Action Required
0020
LDI I/F error.
Transmit data abnormality
detected (NAK reception).
-
1. Observe LEDs. See “Interpreting front panel
LEDs” on page 108.
2. Reseat all cables. See “Reseating cables”
on page 110.
3. Cycle the power supply and try again.
• If the problem is corrected, run Library
Verify before normal library operations
resume.
• If the problem persists, see “Contacting
Dell technical support” on page 111.
0021
LDI I/F error.
Receive timeout detected
(ACK/NAK reception).
-
0022
LDI I/F error.
Response packet reception
timeout detected.
-
0023
LDI I/F error.
ENQ receive timeout detected.
-
0024
LDI I/F error.
Receive data abnormality
detected.
-
0029 LDI command ends abnormally. -
1. Conrm the Encryption Key Manager
settings.
2. Reseat all cables. See “Reseating cables”
on page 110.
3. Cycle the power supply and try again.
• If the problem is corrected, run Library
Verify before normal library operations
resume.
• If the problem persists, see “Contacting
Dell technical support” on page 111.
002A
Commands to the Encryption
Key Manager over the retry limit.
-
002B
Commands to the encryption
capable drive over the retry limit.
-
1. Reseat all cables. See “Reseating cables”
on page 110.
2. Cycle the power supply and try again.
• If the problem is corrected, run Library
Verify before normal library operations
resume.
• If the problem persists, see “Contacting
Dell technical support” on page 111.
Appendix A. Error codes 117