Users Guide

Table 21. Library error codes (continued)
Code (H) Description
Panel
Indication
Action Required
0020
LDI I/F error.
Transmit data abnormality
detected (NAK reception).
-
1. Observe LEDs. See “Interpreting front panel
LEDs” on page 108.
2. Reseat all cables. See “Reseating cables”
on page 110.
3. Cycle the power supply and try again.
If the problem is corrected, run Library
Verify before normal library operations
resume.
If the problem persists, see “Contacting
Dell technical support” on page 111.
0021
LDI I/F error.
Receive timeout detected
(ACK/NAK reception).
-
0022
LDI I/F error.
Response packet reception
timeout detected.
-
0023
LDI I/F error.
ENQ receive timeout detected.
-
0024
LDI I/F error.
Receive data abnormality
detected.
-
0029 LDI command ends abnormally. -
1. Conrm the Encryption Key Manager
settings.
2. Reseat all cables. See “Reseating cables”
on page 110.
3. Cycle the power supply and try again.
If the problem is corrected, run Library
Verify before normal library operations
resume.
If the problem persists, see “Contacting
Dell technical support” on page 111.
002A
Commands to the Encryption
Key Manager over the retry limit.
-
002B
Commands to the encryption
capable drive over the retry limit.
-
1. Reseat all cables. See “Reseating cables”
on page 110.
2. Cycle the power supply and try again.
If the problem is corrected, run Library
Verify before normal library operations
resume.
If the problem persists, see “Contacting
Dell technical support” on page 111.
Appendix A. Error codes 117