Table 21. Library error codes (continued)
Code (H) Description
Panel
Indication
Action Required
0070
Calibration failed because the
accessor contains media.
Suspect the centering sensor.
CHK 0070
1. Attempt to unload the cartridge from the
accessor. See“Moving cartridges” on page
56 (Operator Panel) or “Moving cartridges”
on page 68 (Web User Interface).
2. Cycle the power supply and try again.
If the problem is corrected, run Library
Verify before normal library operations
resume.
If the problem persists, see “Contacting
Dell technical support” on page 111.
0071
Calibration failed due to an
empty magazine. Suspect the
magazine set sensor.
CHK 0071
Cycle the power supply and try again.
If the problem is corrected, run Library Verify
before normal library operations resume.
If the problem persists, see “Contacting Dell
technical support” on page 111.
0072
Calibration measurement invalid
data error. Suspect the centering
sensor, X motor, or P motor.
CHK 0072
0074
GET, centering check, or bar
code reader read operation
failed because the accessor
contains media. Suspect the
centering sensor.
CHK 0074
0075
PUT operation failed because
the accessor contains no media.
Suspect the centering sensor.
CHK 0075
007C
Drive does not enter EJECT state
(and media not ejected) within
200 seconds of a GET command.
Suspect the drive.
CHK 007C
1. If the cartridge does not eject, try to unload
the cartridge from the drive with the
Operator Panel (Commands > Unload) or
the Web User Interface (Manage Library >
Unload). Move the cartridge from the drive
to the I/O Station. Remove the cartridge
from the library and inspect for damage and
replace, if necessary.
2. Cycle the power supply and try again.
If the problem is corrected, run Library
Verify before normal library operations
resume.
If the problem persists, see “Contacting
Dell technical support” on page 111.
120 Dell PowerVault TL1000 Tape Autoloader: User's Guide