Users Guide
Table 21. Library error codes (continued)
Code (H) Description
Panel
Indication
Action Required
007D
Drive does not enter MOUNT
state within 200 seconds of a
PUT command. Suspect the
drive or X motor.
CHK 007D
Cycle the power supply and try again.
• If the problem is corrected, run Library Verify
before normal library operations resume.
• If the problem persists, see “Contacting Dell
technical support” on page 111.
007E
Drive does not enter SET state
within 3 seconds of a PUT
command. Suspect the drive or X
motor.
CHK 007E
007F
Drive I/F or connection error
occurs during a PUT operation or
GET operation. Suspect the
drive.
CHK 007F
1. Reseat all cables. See “Reseating cables”
on page 110.
2. Cycle the power supply and try again.
• If the problem is corrected, run Library
Verify before normal library operations
resume
• If the problem persists, see “Contacting
Dell technical support” on page 111.
Appendix A. Error codes 121