Users Guide

Table 21. Library error codes (continued)
Code (H) Description
Panel
Indication
Action Required
007D
Drive does not enter MOUNT
state within 200 seconds of a
PUT command. Suspect the
drive or X motor.
CHK 007D
Cycle the power supply and try again.
If the problem is corrected, run Library Verify
before normal library operations resume.
If the problem persists, see “Contacting Dell
technical support” on page 111.
007E
Drive does not enter SET state
within 3 seconds of a PUT
command. Suspect the drive or X
motor.
CHK 007E
007F
Drive I/F or connection error
occurs during a PUT operation or
GET operation. Suspect the
drive.
CHK 007F
1. Reseat all cables. See “Reseating cables”
on page 110.
2. Cycle the power supply and try again.
If the problem is corrected, run Library
Verify before normal library operations
resume
If the problem persists, see “Contacting
Dell technical support” on page 111.
Appendix A. Error codes 121