Users Guide

Table 21. Library error codes (continued)
Code (H) Description
Panel
Indication
Action Required
0080
X movement error #1.
During X movement, the target
stop position's origin sensor
error detected. Suspect the X
origin sensor or X motor.
CHK 0080
1. Check the accessor locking screw and
remove it if it is installed. See “Removing
the accessor locking screw” on page 28.
2. Cycle the power supply and try again.
If the problem is corrected, run Library
Verify before normal library operations
resume.
If the problem persists, see “Contacting
Dell technical support” on page 111.
0081
X movement error #2.
During X movement, a motor
sync error detected. Suspect the
X encoder sensor or X motor.
CHK 0081
0082
X movement error #3.
During initialization, a motor
sync error detected. Suspect the
X encoder sensor or X motor.
CHK 0082
0083
During an eject operation or
move operation (to a storage
position), the X origin sensor
could not be detected. Suspect
the X origin sensor or X motor.
CHK 0083
0084
During initialization, the X origin
position could not be detected.
Suspect the X origin sensor or X
motor.
CHK 0084
0088
X calibration error #1.
During X calibration, centering
sensor OFF condition could not
be detected.
CHK 0088
0089
X calibration error #2.
During X calibration, centering
sensor ON condition could not
be detected.
CHK 0089
008F
During X operation, the cartridge
magazine was removed. Suspect
the magazine set sensor.
CHK 008F
1. Conrm that the magazine is closed.
2. Cycle the power supply and try again.
If the problem is corrected, run Library
Verify before normal library operations
resume.
If the problem persists, see “Contacting
Dell technical support” on page 111.
122 Dell PowerVault TL1000 Tape Autoloader: User's Guide