Users Guide

Table 21. Library error codes (continued)
Code (H) Description
Panel
Indication
Action Required
00C8
Centering calibration error #1.
During centering calibration,
centering sensor OFF condition
could not be detected. Suspect
the centering sensor or P motor.
CHK 00C8
Cycle the power supply and try again.
If the problem is corrected, run Library Verify
before normal library operations resume.
If the problem persists, see “Contacting Dell
technical support” on page 111.
00C9
Centering calibration error #2.
During centering calibration,
centering sensor ON condition
could not be detected. Suspect
the centering sensor, X motor, or
P motor.
CHK 00C9
00D0
Checksum error detected during
rmware update.
CHK 00D0
1. Conrm the rmware le version.
2. Reinstall the rmware le.
3. Cycle the power supply and try again.
If the problem is corrected, run Library
Verify before normal library operations
resume.
If the problem persists, see “Contacting
Dell technical support” on page 111.
00D1
Firmware ID error detected
during rmware update.
CHK 00D1
00D2
Boot information error detected
during rmware update.
CHK 00D2
00D3
Bar code reader is not in
maintenance mode during bar
code reader rmware update
(operation interrupted). Suspect
the bar code reader cable
connection.
CHK 00D3
1. Initiate an inventory. See “Conducting a
library inventory” on page 57 (Operator
Panel) or “Conducting a library inventory”
on page 70 (Web User Interface).
2. Cycle the power supply and try again.
If the problem is corrected, run Library
Verify before normal library operations
resume.
If the problem persists, see “Contacting
Dell technical support” on page 111.
00D9
Magazine failed to unlock.
Suspect the magazine or
magazine sensor.
CHK 00D9
1. Cycle the power supply and try again.
2. Manually unlock the magazine, remove the
magazine from the library, and inspect it for
damage.
If not damaged, return it to the library and
run Library Verify before normal library
operations resume.
If damaged, replace the magazine.
00DA
I/O Station failed to unlock.
Suspect the magazine or
magazine sensor.
CHK 00DA
Appendix A. Error codes 125