Users Guide

Table 21. Library error codes (continued)
Code (H) Description
Panel
Indication
Action Required
00DD
An error detected during bar
code reader rmware check.
Suspect the bar code reader
cable connection.
CHK 00DD
1. Initiate an inventory. See “Conducting a
library inventory” on page 57 (Operator
Panel) or “Conducting a library inventory”
on page 70 (Web User Interface).
2. Cycle the power supply and try again.
If the problem is corrected, run Library
Verify before normal library operations
resume.
If the problem persists, see “Contacting
Dell technical support” on page 111.
00E0
Write operation not nished
within 1 ms when writing data to
flash memory.
CHK 00E0
Cycle the power supply and try again.
If the problem is corrected, run Library Verify
before normal library operations resume.
If the problem persists, see “Contacting Dell
technical support” on page 111.
00E1
Clear operation not nished
within 10 seconds when clearing
a sector in flash memory.
CHK 00E1
00E2
Error detected in tape library
conguration stored in flash
memory.
CHK 00E2
00E3
Checksum error detected in
flash memory.
CHK 00E3
00F0
Sensor error #1.
Accessor encoder sensor B error
detected during blink check.
Suspect the accessor encoder
sensor B.
CHK 00F0
126 Dell PowerVault TL1000 Tape Autoloader: User's Guide