Users Guide

Table 21. Library error codes (continued)
Code (H) Description
Panel
Indication
Action Required
00F1
Sensor error #2.
Accessor encoder sensor A error
detected during blink check.
Suspect the accessor encoder
sensor A.
CHK 00F1
Cycle the power supply and try again.
If the problem is corrected, run Library Verify
before normal library operations resume.
If the problem persists, see “Contacting Dell
technical support” on page 111.
00F2
Sensor error #3.
X encoder sensor error detected
during blink check. Suspect the
X encoder sensor.
CHK 00F2
00F3
Sensor error #4.
Magazine sensor error detected
during blink check. Suspect the
magazine sensor.
CHK 00F3
00F8
Sensor error #5.
X origin sensor error detected
during blink check. Suspect the
X origin sensor.
CHK 00F8
00F9
Sensor error #6.
Cartridge sensor error detected
during blink check. Suspect the
cartridge sensor.
CHK 00F9
00FA
Sensor error #7.
accessor forward sensor error
detected during blink check.
Suspect the accessor forward
sensor.
CHK 00FA
00FB
Sensor error #8.
accessor origin sensor error
detected during blink check.
Suspect the accessor origin
sensor.
CHK 00FB
Appendix A. Error codes 127