Users Guide

Table 8. Environmental specications (continued)
Parameter Operating (see Note) Storage Shipping
Note: The operating environment of the library must not conflict with the media storage requirements. The
library can operate at elevated temperatures for an extended period. However, the temperature might shorten
the useful life of media that is stored in the library. If media is stored in the library for more than 10 hours, the
storage temperature requirements for media are met. It is assumed that media that is stored in the library is
approximately 2 degrees above ambient temperature when the library is powered ON.
Table 9. Operational specications
Parameter Model S8H Model S7H Model S6H Model S5H Model S4H
Maximum
storage capacity
108 TB (270 TB
with 2.5:1
compression)
54 TB (135 TB
with 2.5:1
compression)
22.5 TB (56.2 TB
with 2.5:1
compression)
13.5 TB (27 TB
with 2:1
compression)
7.2 TB (14.4 TB
with 2:1
compression)
Maximum
number of data
cartridges
9 (including an optional I/O Station)
Drive types Ultrium 8 Half
Height
Ultrium 7 Half
Height
Ultrium 6 Half
Height
Ultrium 5 Half
Height
Ultrium 4 Half
Height
Sustained native
data transfer
rate
300 MB/s (750
MB/s with 2.5:1
compression)
300 MB/s (750
MB/s with 2.5:1
compression)
160 MB/s (400
MB/s with 2.5:1
compression)
140 MB/s (280
MB/s with 2:1
compression)
120 MB/s (240
MB/s with 2:1
compression)
Interface 6 Gb/s SAS 3 Gb/s SAS
Note: The Ultrium 4 Half Height tape drive in S4H libraries that are manufactured after March 2011 support
6.0 Gb/s and a sustained native data rate of 120 Gb/s.
Table 10. Acoustical specications
Parameter Measurement
Idling acoustical noise sound power level LwAD in
Bels (1 Bel = 10 dB)
6.6
Maximum acoustical noise sound power level LwAD in
Bels (1 Bel = 10 dB)
6.8
Product environment
The TL1000 Tape Autoloader is designed to operate in a general business environment.
The library meets the acoustical requirements for general business area category 2D. Category 2D states
that the library can be installed a minimum of 4 m (13 ft.) from a permanent work station.
To allow for service access, install the library a minimum of 0.9 m (3 ft.) from all obstacles.
The library is a precision computer peripheral device. To ensure maximum longevity of your library, locate
the library away from dust, dirt, and airborne particulates, as follows:
Keep the library away from high-trafc areas, especially if the floor is carpeted. Carpeting harbors dust
and walking on the carpet can cause the carpet bers and the dust to become airborne.
Keep the library out of printer and copier rooms because of toner and paper dust. Additionally, do not
store paper supplies next to the library.
Keep the library away from moving air caused by doorways, open windows, fans, and air conditioners.
Chapter 1. Product description
11