Table 8-3. Warning Events (continued)
81 Fan Alert.
82 Clean request from drive.
83 Media Attention.
84 Drive reported warning or critical tape
alert flag.
85 Network problem. Check network connections, configuration, and settings.
86 Not enough cleaning cartridges present
to autoclean.
Insert additional cleaning cartridges to the empty reserved
slots.
87 Drive disabled because it is not
supported for use in this library.
Check drive type and install only supported drives.
88 Drive firmware unchanged after
upgrade.
This is normal if the old and new drive firmware are the
same version.
89 Power Supply Fan operation warning. Check the power supply status.
8A Power Supply has failed. Check the power supply status and replace the failed power
supply.
8B Power supply has failed. Check the power supply status and replace the failed power
supply.
8C Invalid Robotic Code. Install the latest version of library firmware.
8E Cleaning tape nearly expired. Continue using cleaning cartridge until it is expired, then
replace the expired cleaning cartridge with a new cleaning
cartridge.
8F I2C bus recovery. Run library System Test.
92 VPD data have been restored from
EEPROM.
This is normal when the VPD has been restored EEPROM.
DB External cooling fan error (fan motion
has stopped).
The subcode indicates which drive sled
fan is affected
Subcode 01: drive sled #1(bottom)
Subcode 02: drive sled #2
Refer to “Isolating Drive Sled Problems” on page 7-9.
DC I
2
C Bus Failure
Refer to “Isolating a Power Supply Problem” on page 7-7.
DD Power Supply x fan has failed,
Redundancy may be at risk
The subcode indicates which power
supply fan is affected
Subcode 01: 1st PS fan from bottom
Subcode 02: 2nd PS fan from bottom
DF Power Good signal changed from 2 to 1
Power Supplies
F6 No drive installed. A drive has never
been installed.
Install at least one drive.
Chapter 8. Error Codes 8-13