CLI Guide

Table Of Contents
InfiniBand.NICConfig
The following section provides information about the objects in the InfiniBand.NICConfig group.
InfiniBand.NICConfig.BannerMessageTimeout (Read or Write)
Description
Specify the number of seconds that the OptionROM banner is displayed during POST.
Legal Values
Integral values from 0 - 14
Default Value None
Write Privilege Server Control
License Required iDRAC Express or iDRAC Enterprise
Dependancy None
InfiniBand.NICConfig.BootRetryCnt (Read or Write)
Description
Specify the number of retries to attempt in case of boot failure.
Legal Values
NoRetry-0
1Retry-1
2Retries-2
3Retries-3
4Retries-4
5Retries-5
6Retries-6
IndefiniteRetries
Default Value NoRetry
Write Privilege Server Control
License Required iDRAC Express or iDRAC Enterprise
Dependancy None
InfiniBand.NICConfig.BootStrapType (Read or Write)
Description
Specify the boot strap method used to boot to the operating system.
Legal Values
AutoDetect - 0
BBS - 1
Int18h - 2
Int19h - 3
Default Value AutoDetect
Write Privilege Server Control
License Required iDRAC Express or iDRAC Enterprise
Dependancy None
InfiniBand.NICConfig.LegacyBootProto (Read or Write)
Description
Selects a non-UEFI network boot protocol.
854 InfiniBand Attributes