Owners Manual
Table Of Contents
- Dell Precision 7920 Tower Owner's Manual
- Contents
- Chassis
- Working on your computer
- Removing and installing components
- Screw size list
- Recommended tools
- Power supply unit (PSU)
- Side cover
- Air shroud
- Front bezel
- PCIe holder
- Intrusion switch
- Front system fan assembly
- Internal chassis speaker
- Hard disk drive and the Optical disk drive bezel
- Hard disk drive assembly
- NVMe Flexbay
- Front input and output bezel
- Front input and output panel
- Rear system fan
- Right side cover
- Hard disk drive and optical disk drive frame
- Slim Optical Disk Drive
- 5.25-inch optical drive
- Power distribution and fan control board
- Front HDD cable and fan assembly
- Fan bracket
- Graphical processing unit(GPU)
- Memory
- Coin cell battery
- Processor heat sink module
- System board
- RAID controller battery
- VROC module
- Technology and components
- System specifications
- System Setup
- Software
- Troubleshooting
- Contacting Dell
Table 4. Features of MegaRAID 9440-8i and 9460-16i controller (continued)
9440-8i 9460-16i
Host Bus Type PCIe 3.1 x8 PCIe 3.1 x8
Cache Protection N/A
CacheVault
CVPM05
Physical Dimensions 6.127” x 2.712” (155.65 mm x 68.90 mm) 6.127” x 2.712” (155.65 mm x 68.90 mm)
Maximum Operating Conditions
Operating:
10°C to 55°C
20 to 80% non-condensing
Airflow: 300 LFM
Storage:
-45°C to 105°C
5 to 90% non-condensing
Operating:
10°C to 55°C
20 to 80% non-condensing
Airflow: 300 LFM
Storage:
-45°C to 105°C
5 to 90% non-condensing
MTBF (Calculated) >3,000,000 hours at 40C >3,000,000 hours at 40C
Operating Voltage +12V +/-8%; 3.3V +/-9% +12V +/-8%; 3.3V +/-9%
Hardware Warranty 3 years; with advanced replacement
option
3 years; with advanced replacement
option
MegaRAID Management Suite
LSI Storage Authority (LSA)
StorCLI (command-line interface),
CTRL-R (BIOS configuration utility), HII
(UEFI Human Interface Infrastructure)
LSI Storage Authority (LSA)
StorCLI (command-line interface),
CTRL-R (BIOS configuration utility), HII
(UEFI Human Interface Infrastructure)
Regulatory Certifications
USA (FCC 47 CFR part 15 Subpart B,
class B); Canada (ICES -003, Class B);
Taiwan (CNS 13438); Japan (VCCI V-3);
Australia/New Zealand (AS/NZS CISPR
22); Korea (RRA no 2013-24 & 25);
Europe (EN55022/EN55024);
Safety: EN/IEC/UL 60950; RoHS; WEEE
USA (FCC 47 CFR part 15 Subpart B,
class B); Canada (ICES -003, Class B);
Taiwan (CNS 13438); Japan (VCCI V-3);
Australia/New Zealand (AS/NZS CISPR
22); Korea (RRA no 2013-24 & 25);
Europe (EN55022/EN55024);
Safety: EN/IEC/UL 60950; RoHS; WEEE
OS Support Microsoft Windows, VMware vSphere/
ESXi, Red Hat Linux, SuSe Linux, Ubuntu
Linux, Oracle Linux, CentOS Linux,
Debian Linux, Fedora, and FreeBSD.
Contact Oracle support for Oracle
Solaris driver or software support.
Microsoft Windows, VMware vSphere/
ESXi, Red Hat Linux, SuSe Linux, Ubuntu
Linux, Oracle Linux, CentOS Linux,
Debian Linux, Fedora, and FreeBSD.
Contact Oracle support for Oracle
Solaris driver or software support.
Teradici PCoIP
This section provides an overview of the host driver installation process.
Installing the Teradici PCoIP Card Host Dual/Quad
Install the PCoIP host driver software from dell.com/support.
NOTE:
You cannot upgrade the PCoIP host driver software while a VMware View-brokered PCoIP session is active
between a host workstation or host PC and VMware View client. Doing this will result in losing access to your mouse and
keyboard when the driver software is removed.
Technology and components 91