Owners Manual
Table Of Contents
- Dell Precision Rack 7910 Owner's Manual
- Contents
- Working on your computer
- LCD panel features
- Hard drive indicator codes
- Installing and removing system components
- Safety instructions
- Before working inside your system
- After working inside your system
- Recommended tools
- System Overview
- Front bezel (optional)
- Removing the system cover
- Installing the system cover
- Inside the system
- Cooling shroud
- System memory
- General memory module installation guidelines
- Sample memory configurations
- Removing memory modules
- Installing memory modules
- Hard drives
- Removing a 2.5 inch hard-drive blank
- Installing a 2.5 inch hard-drive blank
- Removing Hard Drive
- Installing Hard Drive
- Removing a hard drive from a hard-drive carrier
- Installing a hard drive into a hard-drive carrier
- Optical drive (optional)
- Cooling fans
- Removing a cooling fan
- Installing a cooling fan
- Removing the cooling-fan assembly
- Installing the cooling-fan assembly
- Internal USB memory key (optional)
- Replacing the internal USB key
- PCIe card holder
- Cable retention bracket
- Expansion cards and expansion card risers
- Expansion card installation guidelines
- Removing an expansion card from expansion-card riser 2 or 3
- Installing an expansion card into the expansion-card riser 2 or 3
- Removing an expansion card from the expansion-card riser 1
- Installing an expansion card into the expansion-card riser 1
- Removing the riser 1 blank
- Installing the riser 1 blank
- Removing expansion-card risers
- Installing expansion-card risers
- GPU card installation guidelines
- Installing a GPU card
- Removing a GPU card
- SD vFlash media card (optional)
- Internal dual SD module (optional)
- Integrated storage controller card
- Network daughter card
- Heat sink and processor
- Power supply units
- Hot spare feature
- Removing the power supply unit blank
- Installing the power supply unit blank
- Removing an AC power supply unit
- Installing an AC power supply unit
- System battery
- Hard-drive backplane
- Removing the hard-drive backplane
- Installing the hard-drive backplane
- Control panel assembly
- System board
- Troubleshooting your system
- Troubleshooting system startup failure
- Troubleshooting external connections
- Troubleshooting the video subsystem
- Troubleshooting a USB device
- Troubleshooting iDRAC Direct (USB XML configuration)
- Troubleshooting iDRAC Direct (laptop connection)
- Troubleshooting a serial I/O device
- Troubleshooting a NIC
- Troubleshooting a wet system
- Troubleshooting a damaged system
- Troubleshooting the system battery
- Troubleshooting power supply units
- Troubleshooting cooling problems
- Troubleshooting cooling fans
- Troubleshooting system memory
- Troubleshooting an internal USB key
- Troubleshooting an SD card
- Troubleshooting an optical drive
- Troubleshooting a hard drive
- Troubleshooting a storage controller
- Troubleshooting expansion cards
- Troubleshooting processors
- Error Messages
- System messages
- Using system diagnostics
- Jumpers and connectors
- Specifications
- System Setup
- Boot Menu
- Timing Key Sequences
- Dell Diagnostics
- About system setup
- Entering System Setup
- System Setup Main Menu
- System BIOS screen
- System Information screen details
- Memory Settings screen details
- Processor Settings screen details
- SATA Settings screen details
- Boot Settings screen details
- Integrated Devices screen details
- Serial Communication screen details
- System Profile Settings screen details
- System Security settings screen details
- Miscellaneous Settings screen details
- NIC indicator codes
- Power indicator codes
- Contacting Dell
Figure 7. Installing the memory module
a. memory module
b. alignment key
c. memory-module socket ejector (2)
When the memory module is properly seated in the socket, the levers on the memory module socket align with the levers on
the other sockets that have memory modules installed.
6. Repeat steps 4 and 5 of this procedure to install the remaining memory modules.
Next steps
1. Install the cooling shroud.
2. Follow the procedure listed in After working inside your system .
3. Press <F2> to enter System Setup, and check the System Memory setting.
The system should have already changed the value to reflect the installed memory.
4. If the value is incorrect, one or more of the memory modules may not be installed properly. Repeat step 4 through step 7 of
this procedure, checking to ensure that the memory modules are firmly seated in their sockets.
5. Run the system memory test in the system diagnostics.
To see a video on how to remove & install memory, scan this QR code, or click here: http://www.Dell.com/QRL/Workstation/
R7910/DIMMs
Hard drives
Your system supports Client and Enterprise-class hard drives, which are designed for 24x7 operating environment. Selecting
the correct drive class will enable the critical areas of quality, functionality, performance, and reliability to be optimized for the
target implementation.
Due to industry advances, in some cases, the larger capacity drives have been changed to a larger sector size. The larger sector
size can have impacts on operating systems and applications.
Installing and removing system components
27