Specifications

PS4000 Hardware Maintenance Basic Array Information
1–4
Warning
condition
LED
Off No power or normal condition.
Flashing orange One or more of the following has occurred:
RAID set is degraded but still functioning.
RAID set (volume level) has lost blocks.
Component temperature is near a limit.
Fan failed or fan RPMs exceed limit.
Power supply is not installed or has no power.
Cache battery has less than 72 hours of charge.
Only one control module installed or control
module has failed over.
Control module has insufficient RAM.
Syncing active and secondary control modules.
No communication between control modules.
Installed spare disk drive does not have enough
capacity to replace a disk drive in a RAID set.
A non-critical hardware component failed.
Real-time clock battery is low.
Critical error
condition
LED
Off No power or normal condition.
Flashing orange One or more of the following has occurred:
RAID is not functioning.
Lost block table is full.
Temperature exceeds upper or lower limit.
Control module cache has lost data.
A cooling module is not installed.
Both fans on a cooling module have failed.
Cache battery temperature is too high to charge
battery.
NVRAM coin cell battery failed.
Cache contains data that does not belong to any of
the installed disk drives.
More than one valid RAID set exists in array.
Control modules are different models.
A critical hardware component has failed.
Operations panel failed or not installed.
Storage enclosure processor that monitors array
components has experienced a failure.
Table 1-2: Operations Panel Descriptions (Continued)
Item Status Description