Users Guide

3–Configuração de fibre channel
Habilitar a correção antecipada de erros da QLogic
107 BK3254601-08 F
O exemplo a seguir mostra a saída do comando fdmishow.
Atributos da porta:
"Device Name: QLogic Adapter"
"Node Name: 20:00:00:0e:1e:80:af:80"
"Port Name: 21:00:00:0e:1e:80:af:78"
"Port Type: 0x5"
"Port Symbolic Name: QLE8362 FW:v7.04.00 DVR:v9.1.12.20 Alpha 2"
"Class of Service: 0x00000008"
"Fabric Name: 10:00:00:05:33:8f:1a:49"
"FC4 Active Type: 0x000001000000000000000000000000000000000000000000000000000"
"Port State: 0x00000002"
"Discovered Ports: 0x00000000"
Atributos do HBA:
"OS Name and Version: Windows Server 2012 R2 Datacenter Evaluation for Intel6 4"
"Max CT Payload Length: 0x00000800"
"Symbolic Name: QLE8362 FW:v7.04.00 DVR:v9.1.12.20 Alpha 2"
"Number of Ports: 1"
"Fabric Name: 10:00:00:05:33:8f:1a:43"
"Bios Version: 3,26"
"Vendor Identifier: QLOGIC"
Habilitar a correção antecipada de erros da QLogic
O QConvergeConsole oferece suporte para o recurso de correção antecipada
de erros (FEC - Forward Error Correction), que é uma técnica de correção usada
em dispositivos de telecomunicações de alta velocidade para controlar erros na
transmissão de dados em canais de comunicação ruidosos ou com baixa
confiabilidade.
O FEC é obrigatório ao operar uma taxa de linha de 32 GB. Adaptadores Gen6
com capacidade de 32 GB são necessários para suportá-lo, e o FEC é
automaticamente ativado ao operar em 32G. Se o adaptador com capacidade de
32 GB estiver operando em 16G, a ativação do FEC é opcional, bem como nos
adaptadores QLE269x-DEL.
NOTA
O comutador e o dispositivo final de fibre channel precisam suportar o
recurso FEC. Consulte a Tabela 3-10 na página 106 para obter a versão
de software do fibre channel suportado.