Users Guide
11–FCoE Configuration
Configuring Linux FCoE Offload
216 AH0054602-00 M
[ 243.991851] [0000:21:00.3]: [qedf_link_update:489]:5: LINK UP (40 GB/s).
3. Check for discovered FCoE devices using the lsscsi or lsblk -S 
commands. An example of each command follows.
# lsscsi
[0:2:0:0] disk DELL PERC H700 2.10 /dev/sda 
[2:0:0:0] cd/dvd TEAC DVD-ROM DV-28SW R.2A /dev/sr0 
[151:0:0:0] disk HP P2000G3 FC/iSCSI T252 /dev/sdb 
[151:0:0:1] disk HP P2000G3 FC/iSCSI T252 /dev/sdc 
[151:0:0:2] disk HP P2000G3 FC/iSCSI T252 /dev/sdd 
[151:0:0:3] disk HP P2000G3 FC/iSCSI T252 /dev/sde 
[151:0:0:4] disk HP P2000G3 FC/iSCSI T252 /dev/sdf 
# lsblk -S
NAME HCTL  TYPE VENDOR   MODEL  REV TRAN
sdb 5:0:0:0 disk  SANBlaze  VLUN P2T1L0 V7.3 fc
sdc 5:0:0:1 disk  SANBlaze  VLUN P2T1L1 V7.3 fc
sdd 5:0:0:2 disk  SANBlaze  VLUN P2T1L2 V7.3 fc
sde 5:0:0:3 disk  SANBlaze  VLUN P2T1L3 V7.3 fc
sdf 5:0:0:4 disk  SANBlaze  VLUN P2T1L4 V7.3 fc
sdg 5:0:0:5 disk  SANBlaze  VLUN P2T1L5 V7.3 fc
sdh 5:0:0:6 disk  SANBlaze  VLUN P2T1L6 V7.3 fc
sdi 5:0:0:7 disk  SANBlaze  VLUN P2T1L7 V7.3 fc
sdj 5:0:0:8 disk  SANBlaze  VLUN P2T1L8 V7.3 fc
sdk 5:0:0:9 disk  SANBlaze  VLUN P2T1L9 V7.3 fc
Configuration information for the host is located in /sys/class/fc_host/hostX, 
where X is the number of the SCSI host. In the preceding example, X is 4. The 
hostX 
file contains attributes for the FCoE function, such as worldwide port name 
and fabric ID.