Users Guide

Table Of Contents
12–Marvell Teaming Services
Event Log Messages
Doc No. BC0054508-00 Rev. R
January 21, 2021 Page 198 Copyright © 2021 Marvell
15 Error Unable to map I/O
space.
The device driver can-
not allocate mem-
ory-mapped I/O to
access driver registers.
Remove other adapt-
ers from the system,
reduce the amount of
physical memory
installed, and replace
the adapter.
16 Informational Driver initialized suc-
cessfully.
The driver has suc-
cessfully loaded.
No action is required.
17 Informational NDIS is resetting the
miniport driver.
The NDIS layer has
detected a problem
sending/receiving pack-
ets and is resetting the
driver to resolve the
problem.
Run QLogic Control
Suite diagnostics;
check that the network
cable is good.
18 Error Unknown PHY
detected. Using a
default PHY initial-
ization routine.
The driver could not
read the PHY ID.
Replace the adapter.
19 Error This driver does not
support this device.
Upgrade to the latest
driver.
The driver does not
recognize the installed
adapter.
Upgrade to a driver ver-
sion that supports this
adapter.
20 Error Driver initialization
failed.
Unspecified failure
during driver initializa-
tion.
Reinstall the driver,
update to a newer
driver, run QLogic Con-
trol Suite diagnostics, or
replace the adapter.
21 Informational Network controller
configured for 10Gb
full-duplex link.
The adapter has been
manually configured for
the selected line speed
and duplex settings.
No action is required.
22 Error Network controller
failed initialization
because it cannot
allocate system
memory.
Insufficient system
memory prevented the
initialization of the
driver.
Increase system mem-
ory.
Table 12-8. Base Driver Event Log Messages (Continued)
Message
Number
Severity Message Cause Corrective Action