Users Guide

Table Of Contents
13–NIC Partitioning and Bandwidth Management
Configuring for NIC Partitioning
Doc No. BC0054508-00 Rev. R
January 21, 2021 Page 206 Copyright © 2021 Marvell
To configure a NIC for partitioning using the CCM utility:
1. Select the NIC from Device List.
2. From the Main Menu, select Device Hardware Configuration.
3. Change the Multi-Function Mode to NPAR.
4. Configure the NIC parameters for your configuration based on the options
shown in Table 13-1, which lists the configuration parameters available on
the NIC Partitioning Configuration window.
In NPAR mode, SR-IOV cannot be enabled on any partition or PF (VNIC) on
which storage offload (FCoE or iSCSI) is configured. This does not apply to
adapters in Single Function (SF) mode.
Configure NPAR mode (and reboot the system) before attempting to
configure the SR-IOV settings on any NPAR-ed partitions of an adapter port.
The NPAR mode configuration will take precedence over the SR-IOV
configuration.
Table 13-1. Configuration Options
Parameter Description Options
Flow Control Configures the Flow Control mode for this port.
Auto
TX Flow Control
RX Flow Control
TX/RX Flow Control
None
PF#0, PF#2, PF#4,
PF#6
Displays the physical function (PF) information
regarding the partition(s) on port 0. Select to config-
ure.
See Table 13-2 for con-
figuration options.
PF#1, PF#3, PF#5,
PF#7
Displays the physical function (PF) information
regarding the partition(s) on port 1. Select to config-
ure.
See Table 13-2 for con-
figuration options.
Reset Configuration to
Default
Resets the NIC partition configuration to the factory
default settings.