16–SR-IOV
SR-IOV and Jumbo Packets
Doc No. BC0054508-00 Rev. R
January 21, 2021 Page 251 Copyright © 2021 Marvell
This limitation applies only when the adapter is configured in NPAR mode. It is not
relevant when the adapter is configured in single-function (SF) mode.
In ESX, after enabling SR-IOV in the OS for SF mode, the storage adapter will not
be discovered.
SR-IOV and Jumbo Packets
If SR-IOV is enabled on a virtual function (VF) on the adapter, ensure that the
same jumbo packet settings is configured on both the VF and the Microsoft
synthetic adapter. You can configure these values using Windows Device
Manager, Advanced properties.
If there is a mismatch in the values, the SR-IOV function is shown as being in the
degraded state in Hyper-V, Networking Status.