The mdmonitor service displays an error during
operating system installation
Description: When the operating system is installed on a virtual disk that is created by Dell EMC S150 RAID Controller,
the following error message is observed during installation:
[FAILED] Failed to start Software RAID monitoring and management
This issue is a cosmetic issue and can be ignored. The operating system installation completes
successfully.
Applies to: Red Hat Enterprise Linux 8 and later
Solution: The issue is resolved in Red Hat Enterprise Linux 8.4
Systems
affected:
Dell EMC PowerEdge yx4x and yx5x servers
Tracking number: 178369
The dmidecode utility displays the slot type as <OUT
OF SPEC> for PCIe Gen 4 NVMe slots
Description:
The dmidecode utility displays the Slot Type field of Type 9 record as <OUT OF SPEC> for PCIe
Generation 4 NVMe slots.
Applies to: Red Hat Enterprise Linux 8.2 and later
Cause: The dmidecode utility does not support the Slot Type value of 0x24 that is defined in System
Management BIOS (SMBIOS) version 3.4.
Solution: The issue is resolved in Red Hat Enterprise Linux 8.4
Systems
affected:
Dell EMC PowerEdge R6515, Dell EMC PowerEdge R7515, Dell EMC PowerEdge R6525, Dell EMC
PowerEdge R7525, and Dell EMC PowerEdge C6525.
Tracking number: 171941
The mcelog utility logs 'only decoding architectural
errors' message in var/log/messages
Description:
The mcelog utility logs 'only decoding architectural errors' message in /var/log/messages.
mcelog: Family 6 Model 106 CPU: only decoding architectural errors
mcelog: Family 6 Model 106 CPU: only decoding architectural errors
Applies to:
Red Hat Enterprise Linux 8.2
Solution: This issue is resolved in Red Hat Enterprise Linux 8.3.
For more information, see Red Hat Enterprise Linux Knowledge Base article 6032341.
Systems
affected:
Dell EMC PowerEdge R750, Dell EMC PowerEdge R650, Dell EMC PowerEdge C6525, Dell EMC
PowerEdge MX750C.
Tracking number: 166937