Installation guide

6 Hardware Installation
Insert Optional Modules
The S60 system has expansion slots at the front left and the rear right of the chassis, that can be used for
SFP+ devices.The following table lists the modules that can be installed into these slots. The modules are
hot-swappable; you can insert or replace modules without powering down the system
To install an optional module, follow the steps below:
2 Cut cable to desired length. Cable length must facilitate the proper operation of fault interrupt circuits.
Force10 recommends using of the shortest cable route allowable.
3 Attach the two-hole lug to the chassis as shown, using the supplied screws.
Any un-plated mating surfaces should be brought to a shiny finish, and apply an anti-oxidant coating
to the surfaces prior to mating. Plated mating surfaces must be clean and free from contamination.
4 Attach the other end of the ground cable to a suitable ground point.
Module Description Catalog Number
2-port 10G SFP+ optical module S60-10GE-2S
Attention: Electrostatic discharge (ESD) damage can occur if components are mishandled. Always wear
an ESD-preventive wrist or heel ground strap when handling the S60 and its components.
Step Task
5 Remove the faceplate covering the module slot located at the rear left or the front right of the S60.
Step Task (Continued)
1