Installation guide

10 Getting Started
Figure 1 S60 serial console port connector
To access the console port, follow the procedures below. Refer to Table 1 for the console port pinout.
Accessing the RJ-45 console port with a DB-9 adapter
You can connect to the console using an RJ-45 to DB-9 adapter along with the RJ-45 rollover cable if the
DTE has a DB-9 interface. Table 1 lists the pin assignments.
Step Task
1
Install an RJ-45 copper cable into the console port. Use a rollover cable to connect the S60 console
port to a terminal server.
2 Connect the other end of the cable to the DTE terminal server.
3 Default terminal settings on the console are set as follows:
9600 baud rate
•No parity
8 data bits
•1 stop bit
No flow control
Table 1 Pin Assignments Between the E300 System Console and a DTE Terminal Server
E300 System
Console Port RJ-45 to RJ-45 Rollover Cable
RJ-45 to DB-9
Adapter
Terminal Server
Device
Signal RJ-45 pinout RJ-45 Pinout DB-9 Pin Signal
RTS 1 8 8 CTS
NC276DSR
TxD 3 6 2 RxD
GND 4 5 5 GND
GND 5 4 5 GND
RxD 6 3 3 TxD
NC 7 2 4 DTR
CTS 8 1 7 RTS
Console
Port