User's Manual

Dell Event ID Alert Description on
Operations Manager
and PRO Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
2076 Virtual Disk Check
Consistency Failed
Critical A physical disk
included in the virtual
disk failed or there is
an error in the parity
information.
Restrict and Migrate
2082 Virtual Disk Rebuild
Failure
Critical A physical disk
included in the virtual
disk has failed or is
corrupt.
Restrict
2083 Physical Disk Rebuild
Failed
Critical A physical disk
included in the virtual
disk has failed or is
corrupt.
Restrict
2094 Predictive Failure
reported
Warning The physical disk is
predicted to fail.
Restrict
2100 Temperature
exceeded Maximum
Warning Threshold
Warning The physical disk
enclosure is too hot.
A variety of factors
can cause the
excessive
temperature.
Restrict
2101 Temperature dropped
below Minimum
Warning Threshold
Warning The physical disk
enclosure is too cool.
Restrict
2102 Temperature
exceeded Maximum
Failure Threshold
Critical The physical disk
enclosure is too hot. A
variety of factors can
cause the excessive
temperature.
Restrict and Migrate
2103 Temperature dropped
below the Minimum
Failure Threshold
Critical The physical disk
enclosure is too cool.
Restrict and Migrate
2112 Enclosure shutdown Critical The physical disk
enclosure is either
hotter or cooler than
the maximum or
minimum allowable
temperature range.
Restrict and Migrate
2122 Redundancy degraded Warning One or more of the
enclosure components
has failed. For
example, a fan or
Restrict
16