Release Notes

28 Dell PowerEdge VRTX Networking | Version 1.6
i. Log in to the switch CLI and go to interface configuration
mode.
ii. Identify the switch port you want to configure.
iii. Enter the appropriate shut/no shut command.
iv. Contact tech support, noting defective ports (i.e., if ports 1/1-
4 did not connect properly, and ports 2/1-4 do, switch is
defective for ports 1/1-4).
o If NIC MAC addresses are still not present after slot move, repeat
previous steps. If these steps fail, the switch as a whole may be
failing:
a. Shut/no shut switch port.
b. Disable/Enable NIC port in OS.
c. Restart blade server.
d. Reseat blade server.
e. Save running-config and reload switch.
f. Save running-config and reseat switch.
g. (Last Resort) Power cycle chassis via CMC CLI or CMC GUI
using the racadm chassisaction powercycle command (shut
down blade servers, then power cycle chassis, confirm switch is
up then power-on blade servers).