PowerEdge MX7000 Management Module QuickSync using the front panel LCD Dell EMC Technical White Paper
Revisions Revisions Date Description Jan 2019 Initial release Acknowledgements This paper was produced by the following members of the Dell EMC storage engineering team: Author: Santosh Bidaralli and Christopher Poblete Dell EMC Technical White Paper
Acknowledgements Table of contents Revisions.............................................................................................................................................................................2 Acknowledgements .............................................................................................................................................................2 Introduction .......................................................................................................
Introduction Introduction PowerEdge MX7000 next-generation modular chassis with the touch screen LCD on the left control panel provides an enhanced graphical capability to the at-the-box chassis management.
QuickSync 2 hardware LCD navigation guide As a guide, the user touch interaction in the figures in this document is depicted as a light green airbrush. Although it is seemingly located at the corner of the screen so that it does not block the button text/icon, the actual press or touch is more effective if done in the middle.
QuickSync setup and connection ] Quicksync disabled QuickSync setup and connection If the Management Module is configured with the default factory password for the admin login then a QR code is displayed on the LCD. (Only shown if the Management Module login credentials are configured with the default factory password, when password has been changed from default NO QR Code is displayed).
QuickSync disconnect and timeout connection is initiated or when Chassis information is accessed from OMM application. OpenManage Mobile application details are outside the scope of this whitepaper. Figure 5 shows successful connection of QuickSync 2 hardware with OpenManage Mobile. QuickSync successful connection Pressing Home button on the connected menu will navigate the LCD to home menu and other features of LCD can be accessed such as Alerts, Settings or System Identity etc.
QuickSync disconnect and timeout QuickSync disconnect QuickSync 2 hardware turns OFF its BLW endpoint when it detects no activity for 120 seconds after it starts broadcasting BLE endpoint to initiate connection, OR successful connection with OpenManage Mobile application LCD panel navigates to error menu from depending on current menu (e.g. “Connected Menu” or “QR Code Menu” or “Home Menu”). Figure 8 shows the QuiSync timeout error menu.