Owner's Manual

Command
History
Version 9.3(0.0) Introduced on the S6000.
Version 9.2(0.0) Introduced on the S4820T and MXL.
Version 9.1(0.0) Introduced on the Z9000 and S4810.
Usage
Information
To enable the OpenFlow instance, use the no shutdown command. When you
use the no shutdown command, the OpenFlow instance sends a request to the
OpenFlow controller to establish a connection.
To disable an OpenFlow instance, use the shutdown command. Use the
shutdown command before making any configuration changes to the OpenFlow
instance.
All OpenFlow instances are disabled by default.
Related
Commands
openflow of-instance — Creates or modifies an OpenFlow instance.
controller — Configures the controller used by OpenFlow.
src-suppression
Prevents received packets from being sent out of the ingress port.
Z9000, S4810, S4820T, S6000, and MXL
Syntax
src-suppression
To allow received packets to be sent out of the ingress port, use the src-
suppression disable command.
Defaults none
Command
Modes
OPENFLOW INSTANCE
Command
History
Version 9.3(0.0) Introduced on the S6000.
Version 9.2(0.2) Introduced on the S4820T and MXL.
Version 9.2(0.2) Introduced on the Z9000 and S4810.
Usage
Information
Source suppression prevents received packets from being transmitted from the
ingress port. Source suppression is enabled by default and is applied to all instances
on the switch. If you disable source suppression, received packets can be
transmitted from the ingress port.
47