Owner's Manual

Information Update for the Solaris™
10 Operating System
Creating Virtual Drives on a System With a Dell™
SAS 6/iR Controller
On a system with a Dell SAS 6/iR controller, a firmware conflict may prevent you
from configuring virtual drives using the lsiutil and raidct1 commands in the
Solaris operating system. The system may issue an Operation failed error
message and place the physical drives in an offline state.
Workaround:
Configure virtual drives using the SAS configuration utility. To access the SAS
configuration utility, press <Ctrl-C> when prompted during the BIOS boot
sequence.
Dell PERC 6 Support
If the device driver for Dell PERC 6 controller is not included with the Solaris
operating system, navigate to your system driver download page on
support.dell.com and follow the instructions for downloading and installing the
drivers.
Installing the EMC
®
PowerPath
®
Driver on a
System With a PERC 6/i or CERC6 Controller
A system running Solaris 10 update 5 with a PERC 6/i or CERC6 as a boot
controller may fail to boot after installation of the EMC PowerPath driver. The
fix for this issue will be included in future releases or updates of the Solaris
operating system. Following is the workaround for this issue.
July 2008