Administrator Guide

4 In the right pane, click Create Boot from SAN Copy.
The Create Boot from SAN Copy dialog box opens.
5 (Optional) Modify default settings for the volume copy as needed.
To change the volume name, modify the Name eld.
To change the parent folder for the volume, select a folder in the Volume Folder pane.
To schedule snapshot creation and expiration for the volume, apply one or more snapshot proles by clicking Change across from
Snapshot Proles.
6 Map the recovery volume to the server that will boot from it.
a Click Change across from Server. The Select Server dialog box appears.
b Select the server, then click OK. The Select Server dialog box closes.
c (Optional) Click Advanced Mapping to congure LUN settings, restrict mapping paths, or present the volume as read-only.
7 Click OK.
Change the LUN Used by a Volume/Server Mapping
The logical unit number identies the volume to the server operating system.
1 If the Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
2 Click the Storage tab.
3 In the Storage tab navigation pane, select the volume.
4 In the right pane, click the Mappings tab.
5 In the right pane, select the server for which you want to modify mapping settings, then click Edit Settings.
The Edit Settings wizard opens.
6 Click Continue. The wizard advances to the next page.
7 If you are connected to a Data Collector, select a Storage Center from the drop-down list in the left navigation pane.
8
From the STORAGE menu, select Volumes.
The Volumes view is displayed.
9 Congure the LUN settings:
To specify a specic LUN number, clear the Use next available LUN checkbox, then type the LUN in the LUN to use when
mapping to Volume eld.
To assign the next unused LUN for the server, select the Use next available LUN checkbox.
To make the volume bootable, select the Map volume using LUN 0 checkbox.
10 Click OK.
Specify Which Controller Processes IO for a Volume/Server Mapping
For dual-controller Storage Centers, you can manually specify which controller processes IO for a volume/server mapping. By default, the
Storage Center automatically chooses a controller.
1 If the Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
2 Click the Storage tab.
3 In the Storage tab navigation pane, select the volume.
4 In the right pane, click the Mappings tab.
5 In the right pane, select the server for which you want to modify mapping settings, then click Edit Settings. The Edit Settings wizard
appears.
6 Click Continue. The wizard advances to the next page.
7 Clear the Allow the Storage Center to automatically determine the best Controller to activate Volume on check box.
8 From the Activate Volume on Controller drop-down menu, select the controller that should process IO for the volume/server
mapping.
134
Storage Center Administration