Owners Manual

Figure 10. Removing a fan module
1
Fan module 2 Release tab
2 Rotate the replacement fan module so that the release tab and handle are on the right side.
3 Slide the replacement fan module into the chassis until it is fully seated and the release tab clicks into place.
NOTE
: Allow the enclosure to identify the fan module and determine its status. If the fan module is functioning properly, fan
module’s Module OK LED glows green and the battery fault LED and fan fault LED are o.
Replacing hard drives
The Dell EMC Storage MD1280 enclosure supports hotswappable hard drives and supports up to 84 hard drives in 3.5-inch carriers, which
are installed in a twodrawer, threerow, 14column conguration. Hard drives are connected to a backplane by using Disk Drive in Carrier
(DDIC) hard drive carriers.
Numbering hard drive
Hard drives are numbered in the secli, starting with 0. Dell EMC Storage MD1280 DDIC slots are numbered 1–42 in drive drawer 0, from
front to back and left to right, and 43–84 in drive drawer 1.
NOTE
: The enumeration of hard drives in the secli software is zero-based. The physical enclosure enumerates hard drives
starting from 1.
18 Installing and removing system components