Setup Guide

Technical specifications
The following specifications are only those required by law to ship with your system. For a complete and current listing of the
specifications for your system, go to Dell.com/support and type your Service Tag.
Power rating per
power supply unit
(PSU)
750 W or 1100 W
Heat Dissipation 2891 BTU/hr maximum (750 W PSU)
4100 BTU/hr maximum (1100 W PSU)
NOTE: This system is also designed to be connected to IT power systems with a phase to phase voltage
not exceeding 230 V.
System battery CR 2032 3.0 – V lithium coin cell
Temperature Maximum ambient temperature for continuous operation: 35°C.
NOTE: Certain configurations of this server have been validated to perform at temperatures as high as
45°C (113°F) and with humidity of up to 90 percent (29°C maximum dew point). These configurations
are Dell Fresh Air compliant.
For information about Dell Fresh Air and supported expanded operating temperature range and configurations,
see the Owner’s Manual at Dell.com/storagemanuals.
技术规格
以下仅是依照法律规定随系统附带的规格。若要获取系统规格的当前完整列表,请访问 Dell.com/support 并输入您的服务标签。
每个电源装置 (PSU)
的额定功率
750 W 1100 W
散热
最大值 2891 BTU/hr (750 W PSU)
最大值 4100 BTU/hr (1100 W PSU)
注:该系统还可连接到相间电压不超过 230 V IT 电源系统。
系统电池
CR 2032 3.0 – V 币形锂电池
温度
连续工作时的最高环境温度:35C
注:该服务器的某些配置已经过验证,可在温度高达 45C (113°F)、湿度高达 90%29°C 最高露点)
的条件下工作。这些配置经过 Dell Fresh Air 验证。
有关 Dell Fresh Air 和受支持扩展操作温度范围和配置,请参阅 Dell.com/storagemanuals 上的《用户手册》。
Spesifikasi teknis
Spesifikasi berikut ini hanya yang dipersyaratkan oleh undang-undang untuk dikirimkan bersama sistem Anda. Untuk mengetahui daftar
spesifikasi lengkap dan terbaru untuk sistem Anda, buka Dell.com/support dan ketikkan Tag Servis Anda.
Spesifikasi daya
per unit catu
daya (PSU)
750 W atau 1100 W
Pelepasan Panas 2891 BTU/jam maksimum (750 W PSU)
4100 BTU/jam maksimum (1100 W PSU)
CATATAN: Sistem ini juga dirancang untuk dihubungkan ke sistem daya IT dengan tegangan fase ke fase
yang tidak melebihi 230 V.
Baterai sistem Sel berbentuk koin lithium CR 2032 3.0 – V
Suhu Suhu ruangan maksimum untuk pengoperasian terus menerus: 35 °C
CATATAN: Konfigurasi tertentu dari server ini telah divalidasi untuk melakukan operasi pada suhu
maksimal 45 °C (113 °F) dan dengan kelembapan hingga 90 persen (titik embun maksimum 29 °C).
Konfigurasi ini sesuai dengan ketentuan Dell Fresh Air.
Untuk informasi tentang Dell Fresh Air dan kisaran suhu pengoperasian yang diperluas, lihat Panduan untuk
Pemilik di Dell.com/storagemanuals.
技術仕様
以下の仕様は、お客様のシステムの出荷に際して法律で定められた項目のみ記載しています。お使いのシステムの完全な最新
の仕様リストは、Dell.com/support にアクセスして、サービスタグを入力してください。
電源装置ユニット
(PSU) ごとの電力
定格
750 W または 1100 W
熱消費 最大 2891 BTU/ (750 W PSU)
最大 4100 BTU/ (1100 W PSU)
メモ:本システムは、230 V 以下の相関電圧の IT 電源システムに接続するようにも設計されています。
システムバッテリー
CR 2032 3.0 - V コイン型リチウム電池
温度 継続動作中の最高周辺温度 35
°
C
メモ:サーバーの構成が、温度が 45
°
C (113
°
F) まで、 湿度が最大で 90 %29
°
C の最大露点)で有
効に機能することを確認してください。これらの構成は「Dell Fresh Air」に準拠しています。
Dell Fresh Air および対応する動作温度拡大範囲と設定に関する情報については、Dell.com/storagemanuals
のオーナーズマニュアルを参照してください。
기술 사양
다음은 현지 법률에 따라 시스템과 함께 제공되어야 하는 사양입니다. 시스템의 최신 사양 전체 목록을 확인하려면 Dell.com/support
이동하여 서비스 태그를 입력합니다.
전원 공급 장치
(PSU) 전원 정격
750 W 또는 1100 W
손실
시간당 최대 2891 BTU(750W 전원 공급 장치)
시간당 최대 4100 BTU(1100 W 전원 공급 장치)
: 또한 시스템은 230 V 초과하지 않는 상전압의 IT 전원 시스템에 연결할 있도록 설계되었습니다.
시스템 전지
CR 2032 3.0 - V 리튬 코인
온도
연속 작동시 주변 최대 온도는 35
°
C
: 서버의 특정 구성은 최고 온도 45
°
C(113
°
F) 최고 습도 90% (최고 이슬점 29
°
C)에서 수행할
있도록 검사되었습니다. 이러한 구성은 Dell Fresh Air 호환됩니다.
Dell Fresh Air 지원되는 작동 온도 범위 구성에 관한 자세한 정보는 Dell.com/storagemanuals 소유자
설명서를 참조하십시오.
WARNING: A WARNING indicates a potential for
property damage, personal injury, or death.
CAUTION: A CAUTION indicates potential damage to
hardware or loss of data if instructions are not followed.
NOTE: A NOTE indicates important information that helps
you make better use of your computer.
警告:“警告”表示可能会导致财产损失、人身伤害甚至死亡。
小心:“小心”表示如果不遵循说明,则有潜在的硬件损坏
或数据丢失危险。
注:“注”表示可以帮助您更好地使用计算机的重要信息。
PERINGATAN: PERINGATAN menunjukkan potensi
terjadinya kerusakan properti, cedera pada seseorang,
atau kematian.
PERHATIAN: PERHATIAN menandakan kemungkinan
kerusakan pada perangkat keras atau hilangnya data jika
petunjuk tidak diikuti.
CATATAN: CATATAN menunjukkan informasi penting yang
membantu Anda mengoptimalkan penggunaan komputer Anda.
警告:物的損害、けが、または死亡の原因となる可能性が
あることを示しています。
注意:指示に従わない場合、ハードウェアの損傷やデータ
の損失の可能性があることを示しています。
メモ:備考では、コンピュータを使いやすくするための重
要な情報を説明しています。
경고: 경고는 재산 손실, 신체적 상해 또는 사망 위험이
있음을 알려줍니다.
주의:
주의
지침을 준수하지 않을 경우 하드웨어의
손상 또는 데이터 손실 위험이 있음을 알려줍니다.
: 참고는 컴퓨터의 활용도를 높이는 도움이 되는 중요한
정보입니다.
Dell End User License Agreement
Before using your system, read the Dell Software License
Agreement that shipped with your system. If you do not accept
the terms of agreement, see Dell.com/contactdell.
Save all software media that shipped with your system. These
media are backup copies of the software installed on your
system.
Dell 最终用户许可协议
使用系统前,请阅读系统随附的《Dell 软件许可协议》。如果
您不接受协议条款,请访问 Dell.com/contactdell
保存系统随附的所有软件介质。这些介质是系统中已安装软件
的备份副本。
Perjanjian Lisensi Pengguna Akhir Dell
Sebelum menggunakan sistem Anda, bacalah Perjanjian Lisensi
Pengguna Akhir Dell yang dikirimkan bersama sistem Anda. Jika
Anda tidak menerima persyaratan dari perjanjian tersebut, lihat
Dell.com/contactdell.
Simpan semua media perangkat lunak yang dikirimkan bersama
sistem Anda. Media ini adalah salinan cadangan dari perangkat
lunak yang dipasang di sistem Anda.
Dell エンドユーザーライセンス契約書
システムを使用する前に、システムに同梱の Dell ソフトウェ
アライセンス契約書をお読みください。契約条件に同意しな
い場合は、Dell.com/contactdell をご覧ください。
システムに同梱のソフトウェアメディアをすべて保存しま
す。このメディアはシステムに取り付けたソフトウェアのバ
ックアップコピーです。
Dell 최종 사용자 사용권 계약
시스템을 사용하기 전에 시스템과 함께 제공된 Dell 소프트웨어
사용권 계약을 읽어 보시기 바랍니다. 계약의 약관에 동의하지
않을 경우, Dell.com/contactdell 방문해 주십시오.
시스템과 함께 제공된 모든 소프트웨어 미디어를 저장하십시오.
이러한 미디어는 시스템에 설치된 소프트웨어의 백업용 복사
파일입니다.
Regulatory model/type
管制型号/类型 | Model/jenis regulasi
認可モデル / 認可タイプ | 규정 모델/유형
E31S Series/E31S001
P/N 6WMF9 Rev. A01
© 2016 Dell Inc.
Dell and the Dell logo are trademarks of Dell Inc.
© 2016 Microsoft Corporation.
2016-12
Printed in Malaysia
Service Tag / Default password /
System name
Service Tag: Your system is identified by a unique Express
Service Code and Service Tag. You can find both codes by pulling
out the information tag located at the front of your system.
Default password: The default password of the NAS system is
Stor@ge!
System name: Your system is configured with a default system
name of D<ServiceTag>, where <ServiceTag> is your
System Service Tag.
服务标签/默认密码/系统名称
服务标签:通过唯一的快速服务代码和服务标签识别您的系
统。您可以通过拉出系统正面的信息标签找到这两个代码。
默认密码:NAS 系统的默认密码是 Stor@ge!
系统名称:系统配置的默认系统名称为 D<服务标签>,其中
<服务标签>是您的系统服务标签。
Tag Servis / Sandi bawaan / Nama sistem
Tag Servis: Sistem Anda diidentifikasikan oleh Express yang unik
Kode Servis dan Tag Servis. Anda dapat menemukan kedua kode
dengan menarik keluar tag informasi yang ada di bagian depan
sistem Anda.
Kata sandi bawaan: Kata sandi bawaan dari sistem NAS adalah
Stor@ge!
Nama sistem: Sistem Anda dikonfigurasi dengan nama
sistem bawaan D<ServiceTag>, dimana <ServiceTag>
merupakan Tag Servis Sistem Anda.
サービスタグ/デフォルトのパスワード/
システム名
サービスタグ:お使いのシステムは固有の Express サービス
コードとサービスタグで識別されます。システムの前面にある
情報タグを引き出して両方のコードを確認できます。
デフォルトパスワード:NAS システムのデフォルトパスワー
ドは、Stor@ge!です。
システム名:システムは、D<ServiceTag> のデフォルトの
システム名で構成され、この <ServiceTag> はシステムの
サービスタグです。
서비스 태그/기본 암호/시스템 이름
서비스 태그: 시스템이 특급서비스 코드 서비스 태그로
식별됩니다. 시스템 전면에 부착된 정보 태그에서 코드를
확인할 있습니다.
기본 암호: NAS 시스템의 기본 암호는 Stor@ge!입니다.
시스템 이름: 시스템은 기본 시스템 이름 D<ServiceTag>
구성되며 <ServiceTag> 시스템의 서비스 태그입니다.
本產品符合臺灣 RoHS 標準 CNS15663
單元
限用物質及其化學符號
(Pb) (Hg) (Cd) 六價鉻 (Cr
+6
) 多溴聯苯 (PBB) 多溴二苯醚
(PBDE)
機箱/檔板
o o o o o
機械部件
(風扇、散熱器等)
o o o o o
電路板組件
o o o o o
電線/連接器
o o o o o
電源設備
o o o o o
儲存裝置
(硬碟、光碟機等)
o o o o o
輸入裝置
(鍵盤、滑鼠等)
o o o o o
喇叭/麥克風
o o o o o
配件
o o o o o
備考 1. “o” 係指該項限用物質之百分比含量未超出百分比含量基準值。
備考 2. 係指該項限用物質為排除項目。