Administrator Guide

iSCSICongure the iSCSI initiator on the server to use the Storage Center HBAs as the target.
Fibre ChannelCongure Fibre Channel zoning to allow the server HBAs and Storage Center HBAs to communicate.
SAS – Directly connect the controller to a server using SAS ports congured as front-end connections.
2 If you are connected to a Data Collector, select a Storage Center from the drop-down list in the left navigation pane.
3 From the STORAGE menu, select Servers.
The Servers view is displayed.
4 Click (New), then select New Server.
The New Server dialog box opens.
5 Congure the server attributes.
The server attributes are described in the online help.
a Enter a name for the server in the Name eld.
b Select a server folder from the Server Folder drop-down menu.
c Select the operating system for the server from the Operating System drop-down menu.
d To generate Storage Center alerts when connectivity is lost between the Storage Center and the server, select Alert On Lost
Connectivity.
e To generate Storage Center alerts when the Storage Center only has partial connection to the server, select Alert On Partial
Connectivity.
f Select or dene one or more HBAs for the server.
If one or more server HBAs are visible to the Storage Center, select the checkboxes of the HBAs to add from the HBAs
table.
If a server HBA is not visible to the Storage Center, click (New) to dene it manually. For SAS front-end connections, use
the SAS device name as the World Wide Name (WWN) to manually add the HBA.
NOTE
: IP addresses can be added for HBAs that will be installed on the server in the future. When the HBA that uses
that IP address is installed, it will be congured and ready to use.
6 Click OK.
Related links
Congure Front-End I/O Ports (Fibre Channel and SAS)
Congure Front-End I/O Ports (iSCSI)
Create a Virtual Server
Create a virtual server object to represent a virtual machine in your environment.
Prerequisite
The server that hosts the virtual server must be added as a physical server.
Steps
1 Make sure the server HBAs have connectivity to the Storage Center HBAs.
iSCSICongure the iSCSI initiator on the server to use the Storage Center HBAs as the target.
Fibre ChannelCongure Fibre Channel zoning to allow the server HBAs and Storage Center HBAs to communicate.
SAS – Directly connect the controller to a server using SAS ports congured as front-end connections.
2 If you are connected to a Data Collector, select a Storage Center from the drop-down list in the left navigation pane.
3
From the STORAGE menu, select Servers.
The Servers view is displayed.
4 Select the server that hosts the virtual server in the Server view.
5 Click (New) and select New Virtual Server.
The New Virtual Server dialog box opens.
6 Congure the server attributes.
88
Storage Center Server Administration