Release Notes

Table Of Contents
Table 30. Known Storage Manager Client Issues in Storage Manager 2019 R1 (continued)
Issue Description
DSM-26168 The Storage Manager Client displays the delete option when volumes and volume folders are
selected. However, the Storage Manager Client does not support deleting volumes and volume
folders in one action.
Workaround: Delete volumes and volume folders separately.
DSM-14009 Refreshing the Storage Manager Client does not clear the red dot indicator from the Storage
Center node.
Workaround: Restart the Storage Manager Client.
DSM-9577 The front-end SAS card for an SCv2000 series controller does not provide WWN information
to ESXi host.
Workaround: Record the SAS WWN information before installing it in an ESXi hosts.
DSM-9477 The Storage Manager Client might report that a restart in sequence has completed even
though the restart has not completed.
Workaround: Verify that the restart completes before continuing.
DSM-7908 The I/O Usage report that is exported in XML format does not display all the information for
the French output when opened in a web browser.
Workaround: Open the report using a text editor such as Notepad.
SCOS-12316 The Storage Manager Client displays multi-VLAN tagging options for I/O cards that do not
support multi-VLAN tagging.
Workaround: Do not enable multi-VLAN tagging on QLogic cards that do not support it.
Known Issues Related to the Storage Manager Virtual Appliance
The following known issues are related to the Storage Manager Virtual Appliance:
Table 31. Known Storage Manager Virtual Appliance Issues in Storage Manager 2019 R1
Issue Description
DSM-46304 The Maximum Server Memory Usage setting of the Storage Manager Virtual Appliance is
displayed incorrectly in the Advanced area on the General > Summary tab of the Data
Collector view in Unisphere Central.
Workaround: None
DSM-45979 When the Storage Manager Client is connected to a Storage Manager Virtual Appliance, the
Store report in public directory option is displayed in the Automated Reports tab of the Edit
Data Collector Settings dialog box, but the option is not supported by the Storage Manager
Virtual Appliance.
Workaround: None
Known Issues Related to SupportAssist and Updating
The following known issues are related to SupportAssist and updating systems:
Table 32. Known SupportAssist and Updating Issues in Storage Manager 2019 R1
Issue Description
DSM-36088 Occasionally, when starting a non-service affecting update for a Storage Center through the
Data Collector, Storage Manager loses connectivity with the Storage Center.
Workaround: The system automatically resolves the connectivity issue.
16