Release Notes
Table Of Contents
- Storage Manager 2019 R1 Release Notes
- Document Revision History
- Management Compatibility
- Software and Hardware Requirements
- New in Storage Manager 2019 R1.10
- New in Storage Manager 2019 R1
- Fixed Issues
- Fixed Issues Related to Cross-Platform Replication
- Fixed Issues Related to the Data Collector
- Fixed Issues Related to Data Reduction
- Fixed Issues Related to Dell Storage Replication Adapter (SRA)
- Fixed Miscellaneous Issues
- Fixed Issues Related to Management of PS Series Groups
- Fixed Issues Related to Replications and Live Volumes
- Fixed Issues Related to the Storage Manager Client
- Fixed Issues Related to the Storage Manager Virtual Appliance
- Fixed Issues Related to the Unisphere Discovery Utility
- Fixed Issues Related to the Unisphere Web Interface
- Fixed Issues Related to User Management
- Fixed Issues Related to VMware
- Known Issues
- Known Issues Related to Cross-Platform Replication
- Known Issues Related to the Data Collector
- Known Issues Related to Data Reduction
- Known Issues Related to the Dell Storage Replication Adapter (SRA)
- Known Miscellaneous Issues
- Known Issues Related to PS Series Group Management
- Known Issues Related to Replications and Live Volumes
- Known Issues Related to Storage Management
- Known Issues Related to the Storage Manager Client
- Known Issues Related to the Storage Manager Virtual Appliance
- Known Issues Related to SupportAssist and Updating
- Known Issues Related to the Unisphere Web Interface
- Known Issues Related to User Management
- Known Issues Related to VMware
- Notes and Limitations
- Documentation Correction
- Support Resources
Table 33. Known Unisphere Web Interface Issues in Storage Manager 2019 R1 (continued)
Issue Description
DSM-28814 In the Filters dialog box, when a value with multiple decimal places is typed into a storage size
or network speed field, the value is not parsed correctly and the filter does not work.
Workaround: None
DSM-26784 In the Filters dialog box of the global Volumes view, the Equal to option in the % Full
drop-down menu does not work.
Workaround: None
DSM-16373 Unisphere Central does not show the progress of a Data Collector data source change.
Workaround: Use the Storage Manager Client to change the data source of a Data Collector.
Known Issues Related to User Management
The following known issues are related to user management:
Table 34. Known User Management Issues in Storage Manager 2019 R1
Issue Description
DSM-35710 Storage Center does not restrict directory service communication to manually defined LDAP
servers. This issue might cause delays when joining Storage Center to a directory environment
or failures when adding directory users and groups to Storage Center for authentication.
Workaround: None
DSM-35011 Cannot configure OpenLDAP directory server using Storage Manager or Unisphere.
Workaround: None
DSM-24536 Attempting to use the characters < or > in User and User Group settings might result in an
error.
Workaround: Do no use these characters in User and User Group settings.
DSM-15445 Adding Storage Manager to Active Directory fails when you use the distinguished name (DN)
of a user.
Workaround: Use the user principal name (UPN) to add Storage Manager to an Active
Directory realm.
DSM-12329 When a user is unlocked, the status of the user might not change immediately.
Workaround: Refresh the Storage Manager Client.
SCOS-11192 Storage Center cannot authenticate directory service users that are configured to use an
alternate DNS suffix.
Workaround: None
Known Issues Related to VMware
The following known issues are related to VMware in Storage Manager 2019 R1:
Table 35. Known VMware Issues in Storage Manager 2019 R1
Issue Description
DSM-44104 Frequently migrating virtual machines from one vVol datastore to another vVol datastore
might result in orphaned volumes.
Workaround: None
DSM-31875 The VMware host setup is incorrectly configuring the iSCSI HBA Login Timeout as 60 seconds.
18